The scientific basis for visible particle inspection
The following paper was presented at the 1999 PDA International Conference in Tokyo, Japan February 24, 1999. The paper was written in response to the recent well-publicized incidents in Japan in which the presence of visible particulates in injectable products was observed. These incidents should b...
Saved in:
| Published in: | PDA journal of pharmaceutical science and technology Vol. 53; no. 6; p. 291 |
|---|---|
| Main Author: | |
| Format: | Journal Article |
| Language: | English |
| Published: |
United States
01.11.1999
|
| Subjects: | |
| ISSN: | 1079-7440 |
| Online Access: | Get more information |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Summary: | The following paper was presented at the 1999 PDA International Conference in Tokyo, Japan February 24, 1999. The paper was written in response to the recent well-publicized incidents in Japan in which the presence of visible particulates in injectable products was observed. These incidents should be considered a wake-up call to all concerned with injectable pharmaceutical products. The overview of visible particle inspection presented at the Tokyo PDA Meeting is reprinted here as a reminder that a global marketplace requires well-defined parameters and evaluation methods. In the absence of these basic requirements continuation of the present conflicting particle contamination evaluations will continue by default. At this time, visible particle inspection around the world lacks both direction and an accepted common language. The adoption of the probabalistic concepts introduced by Knapp and co-workers in 1980 can supply these basic requirements. The use of the probabalistic model and the statistically defined particle quality regions defined by Knapp and co-workers in 1980 was, at that time, a concept foreign to pharmaceutical quality. In the period since 1980, the methodology then introduced has been expanded and simplified. The analysis used by these workers was similar to that used in life insurance calculations and is just as reliable. The results obtained following the adoption of the framework and probabalistic concepts introduced by Pflug in sterile products since 1973 supports the use of tested and verified probabalistic concepts in the production of injectable products. Pflug's work has provided a basis for the secure communication of sterile production methods and results. This improvement in communication has potentiated a surge in sterile product improvement and a consequent reduction in product cost. The use of the probabalistic model and statistically defined particle contamination quality regions introduced by Knapp and co-workers in 1980 is believed to have a similar potential to improve product quality and reduce inspection costs in visible particle inspection procedures. Application of the probabalistic model results in a numerical evaluation of both the inspection security achieved in rejecting visible defects and the excess cost introduced by the false reject rate of good product. It has the ability to translate the U.S.P. language "essentially free" of particle contamination into objective, reproducible numerical results. Visible particle contamination data can be successfully analyzed only when its probabalistic nature is understood. The effect of disregarding the probabalistic nature of visible inspection data is well illustrated by the results of the landmark 1940 court case brought by Bristol Labs against the F.D.A. The F.D.A. contention that the containers were contaminated with visible particles was challenged by Bristol in a court case. When the experienced inspector, who reported the contamination, was asked to differentiate between good and contaminated ampules on the witness stand he failed to distinguish between them. Consequently, the case was dismissed. Any attempt to devise or analyze visible particle quality limits that is not based on the probabalistic nature of the accept/reject decision process can only result in the frustration and failure experienced by the F.D.A. expert in 1940. In the GMP philosophy, the introduction of any new device or system must be preceded by a validation demonstration. This is to ensure that the new device or system functions at least as well as the device or system to be replaced. The validation of semi- and fully automated systems for the detection of particle contamination rests upon the statistically replicable assessment of the security achieved with human inspection performance. Any attempt to validate an alternative inspection system without a knowledge of its probabalistic nature and the probabalistic nature of the human inspection benchmark performance |
|---|---|
| Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| ISSN: | 1079-7440 |