Task-Dependent Compression Performance Assessment in Body Physiology Signals

Compression of biological signals have great importance in storing, offline processing, and transmission of these signals to other entities. There have been many researches based on assessing the performance of newly published compression methods. Main performance metrics used in these researches are...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:2020 28th Signal Processing and Communications Applications Conference (SIU) s. 1 - 4
Hlavní autoři: Ileri, Fatih, Gokcay, Didem
Médium: Konferenční příspěvek
Jazyk:angličtina
Vydáno: IEEE 05.10.2020
Témata:
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:Compression of biological signals have great importance in storing, offline processing, and transmission of these signals to other entities. There have been many researches based on assessing the performance of newly published compression methods. Main performance metrics used in these researches are the compression ratio (CR) and the error metric, generally the PRD (percent mean square difference). In this research we assess the performance of our compression method in a task-dependent fashion. We applied a neural network based classification on original and compressed EMG signals, collected from subjects participated a defined task. With this approach, we were able to understand what amount of necessary information of EMG signals is suppressed during compression.
DOI:10.1109/SIU49456.2020.9302049