Development of a radiobiological evaluation tool to assess the expected clinical impacts of contouring accuracy between manual and semi-automated segmentation algorithms
RADEval is a tool developed to assess the expected clinical impact of contouring accuracy when comparing manual contouring and semi-automated segmentation. The RADEval tool, designed to process large scale datasets, imported a total of 2,760 segmentation datasets, along with a Simultaneous Truth and...
Gespeichert in:
| Veröffentlicht in: | Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference Jg. 2017; S. 3409 - 3412 |
|---|---|
| Hauptverfasser: | , , , , , , , , , , , , |
| Format: | Tagungsbericht Journal Article |
| Sprache: | Englisch |
| Veröffentlicht: |
United States
IEEE
01.07.2017
|
| Schlagworte: | |
| ISSN: | 1557-170X, 2694-0604, 2694-0604 |
| Online-Zugang: | Volltext |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Zusammenfassung: | RADEval is a tool developed to assess the expected clinical impact of contouring accuracy when comparing manual contouring and semi-automated segmentation. The RADEval tool, designed to process large scale datasets, imported a total of 2,760 segmentation datasets, along with a Simultaneous Truth and Performance Level Estimation (STAPLE) to act as ground truth tumor segmentations. Virtual dose-maps were created within RADEval and two different tumor control probability (TCP) values using a Logistic and a Poisson TCP models were calculated in RADEval using each STAPLE and each dose-map. RADEval also virtually generated a ring of normal tissue. To evaluate clinical impact, two different uncomplicated TCP (UTCP) values were calculated in RADEval by using two TCP-NTCP correlation parameters (δ = 0 and 1). NTCP values showed that semi-automatic segmentation resulted in lower NTCP with an average 1.5 - 1.6 % regardless of STAPLE design. This was true even though each normal tissue was created from each STAPLE (p < 0.00001). TCP and UTCP presented no statistically significant differences (p ≥ 0.1884). The intra-operator standard deviations (SDs) for TCP, NTCP and UTCP were significantly lower for the semi-automatic segmentation method regardless of STAPLE design (p < 0.0331). Both intra-and inter-operator SDs of TCP, NTCP and UTCP were significantly lower for semi-automatic segmentation for the STAPLE 1 design (p <0.0331). RADEval was able to efficiently process 4,920 datasets of two STAPLE designs and successfully assess the expected clinical impact of contouring accuracy. |
|---|---|
| Bibliographie: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| ISSN: | 1557-170X 2694-0604 2694-0604 |
| DOI: | 10.1109/EMBC.2017.8037588 |