An optimized optical-flow-based method for quantitative tracking of ultrasound-guided right diaphragm deformation

Objectives To develop a quantitative analysis method for right diaphragm deformation. This method is based on optical flow and applied to diaphragm ultrasound imaging. Methods This study enrolls six healthy subjects and eight patients under mechanical ventilation. Dynamic images with 3–5 breathing c...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:BMC medical imaging Ročník 23; číslo 1; s. 108 - 9
Hlavní autoři: Zhang, Qi, Yang, Dawei, Zhu, Yu, Liu, Yatong, Ye, Xiong
Médium: Journal Article
Jazyk:angličtina
Vydáno: London BioMed Central 17.08.2023
BioMed Central Ltd
BMC
Témata:
ISSN:1471-2342, 1471-2342
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:Objectives To develop a quantitative analysis method for right diaphragm deformation. This method is based on optical flow and applied to diaphragm ultrasound imaging. Methods This study enrolls six healthy subjects and eight patients under mechanical ventilation. Dynamic images with 3–5 breathing cycles were acquired from three directions of right diaphragm by a portable ultrasound system. Filtering and density clustering algorithms are used for denoising Digital Imaging and Communications in Medicine (DICOM) data. An optical flow based method is applied to track movements of the right diaphragm. An improved drift correction algorithm is used to optimize the results. The method can automatically analyze the respiratory cycle, inter-frame/cumulative vertical and horizontal displacements, and strain of the input right diaphragm ultrasound image. Results The optical-flow-based diaphragm ultrasound image motion tracking algorithm can accurately track the right diaphragm during respiratory motion. There are significant differences in horizontal and vertical displacements in each section (p-values < 0.05 for all). Significant differences are found between healthy subjects and mechanical ventilation patients for both horizontal and vertical displacements in Section III (p-values < 0.05 for both). There is no significant difference in global strain in each section between healthy subjects and mechanical ventilation patients (p-values > 0.05 for all). Conclusions The developed method can quantitatively evaluate the inter-frame/cumulative displacement of the diaphragm in both horizontal and vertical directions, as well as the global strain in three different imaging planes. The above indicators can be used to evaluate diaphragmatic dynamics.
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1471-2342
1471-2342
DOI:10.1186/s12880-023-01066-7