A point-of-care diagnostic for drug-induced liver injury using surface-enhanced Raman scattering lateral flow immunoassay
Paracetamol overdose (POD) is common, with approximately 100,000 cases attending UK hospitals annually. Timely antidote administration is crucial for patients at risk of developing acute liver failure. A rapid point-of-care (POC) assay is required to identify high-risk patients with fit-for-purpose...
Uložené v:
| Vydané v: | Nature communications Ročník 16; číslo 1; s. 6223 - 13 |
|---|---|
| Hlavní autori: | , , , , , , , , , , , , , , , , |
| Médium: | Journal Article |
| Jazyk: | English |
| Vydavateľské údaje: |
London
Nature Publishing Group UK
06.07.2025
Nature Publishing Group Nature Portfolio |
| Predmet: | |
| ISSN: | 2041-1723, 2041-1723 |
| On-line prístup: | Získať plný text |
| Tagy: |
Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
|
| Shrnutí: | Paracetamol overdose (POD) is common, with approximately 100,000 cases attending UK hospitals annually. Timely antidote administration is crucial for patients at risk of developing acute liver failure. A rapid point-of-care (POC) assay is required to identify high-risk patients with fit-for-purpose sensitivity and specificity. Here we show that by measuring a circulating biomarker, cytokeratin-18 (K18), accurate detection of drug-induced liver injury (DILI) is possible. To achieve this, we created an in vitro diagnostic medical device designed to quantitatively detect serum K18, consisting of a Lateral Flow Immunoassay (LFIA) paired with a bespoke handheld Raman Reader (HRR) to produce quantitative surface-enhanced Raman scattering (SERS). The diagnostic was assessed in 2 performance evaluation studies using 199 serum samples from individuals following POD. The device achieves diagnostic accuracy for DILI with a specificity of 94% and sensitivity of 82%. Here we show that SERS-LFIA can rapidly identify patients with DILI, allowing individualised treatment pathways.
There is an unmet clinical need for a rapid point-of-care tests to identify patients at high-risk of developing acute liver failure following a paracetamol overdose. Here, authors assess a diagnostic test, consisting of a lateral flow immunoassay paired with a handheld Raman reader, in performance evaluation studies. |
|---|---|
| Bibliografia: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
| ISSN: | 2041-1723 2041-1723 |
| DOI: | 10.1038/s41467-025-61600-9 |