Real-time diffusion-perfusion mismatch analysis in acute stroke

Diffusion‐perfusion mismatch can be used to identify acute stroke patients that could benefit from reperfusion therapies. Early assessment of the mismatch facilitates necessary diagnosis and treatment decisions in acute stroke. We developed the RApid processing of PerfusIon and Diffusion (RAPID) for...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Journal of magnetic resonance imaging Ročník 32; číslo 5; s. 1024 - 1037
Hlavní autoři: Straka, Matus, Albers, Gregory W., Bammer, Roland
Médium: Journal Article
Jazyk:angličtina
Vydáno: Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.11.2010
Témata:
ISSN:1053-1807, 1522-2586, 1522-2586
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:Diffusion‐perfusion mismatch can be used to identify acute stroke patients that could benefit from reperfusion therapies. Early assessment of the mismatch facilitates necessary diagnosis and treatment decisions in acute stroke. We developed the RApid processing of PerfusIon and Diffusion (RAPID) for unsupervised, fully automated processing of perfusion and diffusion data for the purpose of expedited routine clinical assessment. The RAPID system computes quantitative perfusion maps (cerebral blood volume, CBV; cerebral blood flow, CBF; mean transit time, MTT; and the time until the residue function reaches its peak, Tmax) using deconvolution of tissue and arterial signals. Diffusion‐weighted imaging/perfusion‐weighted imaging (DWI/PWI) mismatch is automatically determined using infarct core segmentation of ADC maps and perfusion deficits segmented from Tmax maps. The performance of RAPID was evaluated on 63 acute stroke cases, in which diffusion and perfusion lesion volumes were outlined by both a human reader and the RAPID system. The correlation of outlined lesion volumes obtained from both methods was r2 = 0.99 for DWI and r2 = 0.96 for PWI. For mismatch identification, RAPID showed 100% sensitivity and 91% specificity. The mismatch information is made available on the hospital's PACS within 5–7 min. Results indicate that the automated system is sufficiently accurate and fast enough to be used for routine care as well as in clinical trials. J. Magn. Reson. Imaging 2010;32:1024–1037. © 2010 Wiley‐Liss, Inc.
Bibliografie:NIBIB - No. R01EB2711
ark:/67375/WNG-QQRZVK3M-B
istex:540EC44A42FDD580903B2B3AD95D33D6030686EE
ArticleID:JMRI22338
NINDS - No. R01NS39325
NIH - No. 2R01 NS039325
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
ObjectType-Review-3
content type line 23
ISSN:1053-1807
1522-2586
1522-2586
DOI:10.1002/jmri.22338