Evaluation of inert gas rebreathing for determination of cardiac output: influence of age, gender and body size

The aim of this study was to evaluate an inert gas rebreathing method (Innocor) for measurement of cardiac output and related haemodynamic variables and to provide robust normative data describing the influence of age, gender and body size on these variables. Four separate studies were conducted: me...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Hypertension research Ročník 42; číslo 6; s. 834 - 844
Hlavní autori: Middlemiss, Jessica E., Cocks, Alex, Paapstel, Kaido, Maki-Petaja, Kaisa M., Sunita, Wilkinson, Ian B., McEniery, Carmel M.
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: England Nature Publishing Group 01.06.2019
Springer Singapore
Predmet:
ISSN:0916-9636, 1348-4214, 1348-4214
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:The aim of this study was to evaluate an inert gas rebreathing method (Innocor) for measurement of cardiac output and related haemodynamic variables and to provide robust normative data describing the influence of age, gender and body size on these variables. Four separate studies were conducted: measurement repeatability (study 1, n  = 45); postural change (study 2, n  = 40); response to submaximal cycling exercise (study 3, n  = 20); and the influence of age, gender and body size (study 4, n  = 1400). Repeated measurements of cardiac output, stroke volume and heart rate were similar, with low mean (±SD) differences (0.26 ± 0.53 L/min, 0 ± 11 mL and 2 ± 6beats/min, respectively). In addition, cardiac output and stroke volume both declined progressively from supine to seated and standing positions ( P  < 0.001 for both) and there was a stepwise increase in both parameters moving from rest to submaximal exercise ( P  < 0.001 for both). In study 4, there was a significant age-related decline in cardiac output and stroke volume in males and females, which remained significant after adjusting for body surface area (BSA, P  < 0.001 for all comparisons). Both parameters were also significantly higher in those with high body mass index (BMI; P  < 0.01 versus those with normal BMI for all comparisons), although indexing cardiac output and stroke volume to BSA reversed these trends. Inert gas rebreathing using the Innocor device provides repeatable measurements of cardiac output and related indices, which are sensitive to the effects of acute physiological manoeuvres. Moreover, inert gas rebreathing is a suitable technique for examining chronic influences such as age, gender and body size on key haemodynamic components of the arterial blood pressure.
Bibliografia:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0916-9636
1348-4214
1348-4214
DOI:10.1038/s41440-018-0179-1