Relationship between the privacy index and the speech privacy class

It is regularly debated which metric to use for the assessment of architectural speech privacy. For open-plan offices, the Privacy Index, derived from the Articulation Index according to ASTM E1130 (2016), is usually used. For closed offices, the Speech Privacy Class is determined according to ASTM...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:The Journal of the Acoustical Society of America Ročník 145; číslo 5; s. EL435
Hlavní autoři: Müller-Trapet, Markus, Gover, Bradford N
Médium: Journal Article
Jazyk:angličtina
Vydáno: United States 01.05.2019
ISSN:1520-8524, 1520-8524
On-line přístup:Zjistit podrobnosti o přístupu
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:It is regularly debated which metric to use for the assessment of architectural speech privacy. For open-plan offices, the Privacy Index, derived from the Articulation Index according to ASTM E1130 (2016), is usually used. For closed offices, the Speech Privacy Class is determined according to ASTM E2638 (2010). Disregarding the measurement method, and the fact that the metrics show different behavior regarding the Signal-to-Noise Ratio, both metrics are directly related and values of the Speech Privacy Class can thus be converted to Privacy Index values. The relationship is demonstrated and the result is validated with field and laboratory measurement data.
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1520-8524
1520-8524
DOI:10.1121/1.5109049