A comparative study of gradient nonlinearity correction strategies for processing diffusion data obtained with ultra‐strong gradient MRI scanners

Purpose The analysis of diffusion data obtained under large gradient nonlinearities necessitates corrections during data reconstruction and analysis. While two such preprocessing pipelines have been proposed, no comparative studies assessing their performance exist. Furthermore, both pipelines negle...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Magnetic resonance in medicine Ročník 85; číslo 2; s. 1104 - 1113
Hlavní autori: Rudrapatna, Umesh, Parker, Greg D., Roberts, Jamie, Jones, Derek K.
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: United States Wiley Subscription Services, Inc 01.02.2021
John Wiley and Sons Inc
Predmet:
ISSN:0740-3194, 1522-2594, 1522-2594
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:Purpose The analysis of diffusion data obtained under large gradient nonlinearities necessitates corrections during data reconstruction and analysis. While two such preprocessing pipelines have been proposed, no comparative studies assessing their performance exist. Furthermore, both pipelines neglect the impact of subject motion during acquisition, which, in the presence of gradient nonlinearities, induces spatio‐temporal B‐matrix variations. Here, spatio‐temporal B‐matrix tracking (STB) is proposed and its performance compared to established pipelines. Methods Diffusion tensor MRI (DT‐MRI) was performed using a 300 mT/m gradient system. Data were acquired with volunteers positioned in regions with pronounced gradient nonlinearities, and used to compare the performance of six different processing pipelines, including STB. Results Up to 30% errors were observed in DT‐MRI parameter estimates when neglecting gradient nonlinearities. Moreover, the order in which B 0 inhomogeneity, eddy current and gradient nonlinearity corrections were performed was found to impact the consistency of parameter estimates significantly. Although, no pipeline emerged as a clear winner, the STB approach seemed to yield the most consistent parameter estimates under large gradient nonlinearities. Conclusions Under large gradient nonlinearities, the choice of preprocessing pipeline significantly impacts the estimated diffusion parameters. Motion‐induced spatio‐temporal B‐matrix variations can lead to systematic bias in the parameter estimates, that can be ameliorated using the proposed STB framework.
Bibliografia:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
Click here for author‐reader discussions
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.28464