The Human Connectome Project and beyond: Initial applications of 300mT/m gradients

The engineering of a 3T human MRI scanner equipped with 300mT/m gradients – the strongest gradients ever built for an in vivo human MRI scanner – was a major component of the NIH Blueprint Human Connectome Project (HCP). This effort was motivated by the HCP's goal of mapping, as completely as p...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:NeuroImage (Orlando, Fla.) Ročník 80; s. 234 - 245
Hlavní autoři: McNab, Jennifer A., Edlow, Brian L., Witzel, Thomas, Huang, Susie Y., Bhat, Himanshu, Heberlein, Keith, Feiweier, Thorsten, Liu, Kecheng, Keil, Boris, Cohen-Adad, Julien, Tisdall, M. Dylan, Folkerth, Rebecca D., Kinney, Hannah C., Wald, Lawrence L.
Médium: Journal Article
Jazyk:angličtina
Vydáno: Amsterdam Elsevier Inc 15.10.2013
Elsevier Limited
Témata:
ISSN:1053-8119, 1095-9572
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:The engineering of a 3T human MRI scanner equipped with 300mT/m gradients – the strongest gradients ever built for an in vivo human MRI scanner – was a major component of the NIH Blueprint Human Connectome Project (HCP). This effort was motivated by the HCP's goal of mapping, as completely as possible, the macroscopic structural connections of the in vivo healthy, adult human brain using diffusion tractography. Yet, the 300mT/m gradient system is well suited to many additional types of diffusion measurements. Here, we present three initial applications of the 300mT/m gradients that fall outside the immediate scope of the HCP. These include: 1) diffusion tractography to study the anatomy of consciousness and the mechanisms of brain recovery following traumatic coma; 2) q-space measurements of axon diameter distributions in the in vivo human brain and 3) postmortem diffusion tractography as an adjunct to standard histopathological analysis. We show that the improved sensitivity and diffusion-resolution provided by the gradients are rapidly enabling human applications of techniques that were previously possible only for in vitro and animal models on small-bore scanners, thereby creating novel opportunities to map the microstructure of the human brain in health and disease. •Diffusion spectrum imaging to study traumatic coma recovery•In vivo human axon diameter measurements using 300mT/m gradients•High-resolution (0.6mm isotropic) diffusion imaging in whole, fixed human brain
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:1053-8119
1095-9572
DOI:10.1016/j.neuroimage.2013.05.074