Development and Assessment of a Quantitative Reverse Transcription-PCR Assay for Simultaneous Measurement of Four Amplicons

Background: High-throughput and forward-deployable biological dosimetry capabilities are required for tactical and medical decisions after radiologic events. We previously reported a quantitative reverse transcription (QRT)-PCR assay for human radiation-responsive gene targets using a whole-blood ex...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Clinical chemistry (Baltimore, Md.) Ročník 49; číslo 9; s. 1467 - 1475
Hlavní autori: Grace, Marcy B, McLeland, Christopher B, Gagliardi, Steven J, Smith, Jeffrey M, Jackson, William E., III, Blakely, William F
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: Washington, DC Am Assoc Clin Chem 01.09.2003
American Association for Clinical Chemistry
Oxford University Press
Predmet:
ISSN:0009-9147, 1530-8561
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:Background: High-throughput and forward-deployable biological dosimetry capabilities are required for tactical and medical decisions after radiologic events. We previously reported a quantitative reverse transcription (QRT)-PCR assay for human radiation-responsive gene targets using a whole-blood ex vivo irradiation model, but we needed a multitarget assay on a smaller, less costly, real-time PCR detection system. Methods: We developed a quadruplex QRT-PCR assay in a 96-well, closed-plate format suitable for use with RNA extracted from whole blood. Four cDNA targets were simultaneously amplified in a sealed tube by hybridization to exonuclease probes, each conjugated to distinct fluorogenic reporters. A novel primer-limited 18S rRNA reference target was validated from serial dilutions of human total RNA. To test assay precision, we incorporated a positive-control cDNA mimic into duplex and quadruplex PCR reactions. The master mixture was supplemented with more enzyme, MgCl2, and deoxyribonucleotides. Simultaneous detection of four targets was evaluated in comparison with respective duplex QRT-PCR assays. Results: The simultaneous detection of three radiation-responsive genes by quadruplex QRT-PCR was quantitative, with gene expression changes similar to those observed with optimized duplex and triplex QRT-PCR assays. The 18S rRNA and GADD45 calibration curves (threshold cycle vs log10 cDNA) were linear and reproducible and showed optimal PCR efficiencies as indicated by slopes statistically equivalent to the theoretical value of −3.322. Conclusions: This is the first study of a quadruplex QRT-PCR assay. Our approach has diagnostic utility in the detection of biomarkers, biological and toxicologic agents, and genes of inherited diseases and cancer.
Bibliografia:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0009-9147
1530-8561
DOI:10.1373/49.9.1467