Towards an Unbiased Comparison of CC, BCC, and FCC Lattices in Terms of Prealiasing

In the literature on optimal regular volume sampling, the Body‐Centered Cubic (BCC) lattice has been proven to be optimal for sampling spherically band‐limited signals above the Nyquist limit. On the other hand, if the sampling frequency is below the Nyquist limit, the Face‐Centered Cubic (FCC) latt...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Computer graphics forum Ročník 33; číslo 3; s. 81 - 90
Hlavní autori: Vad, Viktor, Csébfalvi, Balázs, Rautek, Peter, Gröller, Eduard
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: Oxford Blackwell Publishing Ltd 01.06.2014
Predmet:
ISSN:0167-7055, 1467-8659
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:In the literature on optimal regular volume sampling, the Body‐Centered Cubic (BCC) lattice has been proven to be optimal for sampling spherically band‐limited signals above the Nyquist limit. On the other hand, if the sampling frequency is below the Nyquist limit, the Face‐Centered Cubic (FCC) lattice was demonstrated to be optimal in reducing the prealiasing effect. In this paper, we confirm that the FCC lattice is indeed optimal in this sense in a certain interval of the sampling frequency. By theoretically estimating the prealiasing error in a realistic range of the sampling frequency, we show that in other frequency intervals, the BCC lattice and even the traditional Cartesian Cubic (CC) lattice are expected to minimize the prealiasing. The BCC lattice is superior over the FCC lattice if the sampling frequency is not significantly below the Nyquist limit. Interestingly, if the original signal is drastically undersampled, the CC lattice is expected to provide the lowest prealiasing error. Additionally, we give a comprehensible clarification that the sampling efficiency of the FCC lattice is lower than that of the BCC lattice. Although this is a well‐known fact, the exact percentage has been erroneously reported in the literature. Furthermore, for the sake of an unbiased comparison, we propose to rotate the Marschner‐Lobb test signal such that an undue advantage is not given to either lattice.
Bibliografia:istex:FB041A0F5C915418A962723E50FA03B6BB9F9A7D
ark:/67375/WNG-V9S37N9N-V
ArticleID:CGF12364
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
ISSN:0167-7055
1467-8659
DOI:10.1111/cgf.12364