Three-Time-Scale Singular Perturbation Stability Analysis of Three-Phase Power Converters

This paper analyzes the stability of the well‐known three‐phase two‐level power converter. Focusing on the rectifier operating mode, the dynamics of the system, when the instantaneous power and dc‐link voltage controllers are included, are described by a set of complex equations that results in a no...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Asian journal of control Ročník 16; číslo 5; s. 1361 - 1372
Hlavní autoři: Umbría, Francisco, Aracil, Javier, Gordillo, Francisco, Salas, Francisco, Sánchez, Juan Antonio
Médium: Journal Article
Jazyk:angličtina
Vydáno: Hoboken Blackwell Publishing Ltd 01.09.2014
Wiley Subscription Services, Inc
Témata:
ISSN:1561-8625, 1934-6093
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:This paper analyzes the stability of the well‐known three‐phase two‐level power converter. Focusing on the rectifier operating mode, the dynamics of the system, when the instantaneous power and dc‐link voltage controllers are included, are described by a set of complex equations that results in a nonlinear autonomous singularly perturbed system. Hence, the closed‐loop system can be studied under the assumption of separate time scales. The analysis proposed in this work follows a novel three‐time‐scale approach, where the fast time scale corresponds with the instantaneous power dynamics, the mid‐range time scale is related to the dc‐link voltage dynamics, and the slow time scale is associated with the dc‐link voltage regulator dynamics. In this way, the analysis leads to the decomposition of the closed‐loop system into three simpler subsystems: fast, medium, and slow subsystems. These subsystems approximate the closed‐loop system behavior over the three different time scales. Finally, since the equilibrium point of each subsystem is exponentially stable and some other conditions are satisfied, it is shown that the equilibrium point of the closed‐loop system also presents exponential stability. Experimental results for a synchronous three‐phase power rectifier prototype are included to corroborate the analysis carried out.
Bibliografie:ark:/67375/WNG-5T5C15RV-Q
ArticleID:ASJC818
Junta de Andalucía P07-TIC-02991
istex:7AD19FDDF3C22708CC969BF2A40EDA8B482A034D
MICINN-FEDER DPI2009-09661
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 14
ISSN:1561-8625
1934-6093
DOI:10.1002/asjc.818