The SSVEP-Based BCI Text Input System Using Entropy Encoding Algorithm

The so-called amyotrophic lateral sclerosis (ALS) or motor neuron disease (MND) is a neurodegenerative disease with various causes. It is characterized by muscle spasticity, rapidly progressive weakness due to muscle atrophy, and difficulty in speaking, swallowing, and breathing. The severe disabled...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Mathematical problems in engineering Ročník 2015; číslo 2015; s. 1 - 8
Hlavní autoři: Tickle, Andrew Jason, Wu, Chung-Min, Zaeni, Ilham A. E., Chen, Shih-Chung, Chen, Yeou-Jiunn, Chen, Pei-Jarn
Médium: Journal Article
Jazyk:angličtina
Vydáno: Cairo, Egypt Hindawi Publishing Corporation 01.01.2015
John Wiley & Sons, Inc
Témata:
ISSN:1024-123X, 1563-5147
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:The so-called amyotrophic lateral sclerosis (ALS) or motor neuron disease (MND) is a neurodegenerative disease with various causes. It is characterized by muscle spasticity, rapidly progressive weakness due to muscle atrophy, and difficulty in speaking, swallowing, and breathing. The severe disabled always have a common problem that is about communication except physical malfunctions. The steady-state visually evoked potential based brain computer interfaces (BCI), which apply visual stimulus, are very suitable to play the role of communication interface for patients with neuromuscular impairments. In this study, the entropy encoding algorithm is proposed to encode the letters of multilevel selection interface for BCI text input systems. According to the appearance frequency of each letter, the entropy encoding algorithm is proposed to construct a variable-length tree for the letter arrangement of multilevel selection interface. Then, the Gaussian mixture models are applied to recognize electrical activity of the brain. According to the recognition results, the multilevel selection interface guides the subject to spell and type the words. The experimental results showed that the proposed approach outperforms the baseline system, which does not consider the appearance frequency of each letter. Hence, the proposed approach is able to ease text input interface for patients with neuromuscular impairments.
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1024-123X
1563-5147
DOI:10.1155/2015/234260