Correlation of Treponemal Immunoassay Signal Strength Values with Reactivity of Confirmatory Treponemal Testing
Automated treponemal immunoassays are used for syphilis screening with the reverse-sequence algorithm; discordant results (e.g., enzyme immunoassay [EIA] reactive and reactive plasma reagin [RPR] nonreactive) are resolved with a second treponemal test. We conducted a study to determine automated imm...
Gespeichert in:
| Veröffentlicht in: | Journal of clinical microbiology Jg. 56; H. 1 |
|---|---|
| Hauptverfasser: | , , , , , , , , |
| Format: | Journal Article |
| Sprache: | Englisch |
| Veröffentlicht: |
United States
01.01.2018
|
| Schlagworte: | |
| ISSN: | 1098-660X, 1098-660X |
| Online-Zugang: | Weitere Angaben |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Zusammenfassung: | Automated treponemal immunoassays are used for syphilis screening with the reverse-sequence algorithm; discordant results (e.g., enzyme immunoassay [EIA] reactive and reactive plasma reagin [RPR] nonreactive) are resolved with a second treponemal test. We conducted a study to determine automated immunoassay signal strength values consistently correlating with reactive confirmatory treponemal testing. We conducted a cross-sectional analysis of four automated immunoassays (BioPlex 2200 microbead immunoassay [MBIA], Liaison chemiluminescence immunoassay [CIA], Advia-Centaur CIA, and Trep-Sure EIA) and three manual assays (
particle agglutination [TP-PA], fluorescent treponemal antibody absorption [FTA-ABS] test, and Inno-LIA line immunoassay). We compared signal strength values of automated immunoassays and positive and negative agreement. Among 1,995 specimens, 908 (45.5%) were true positives (≥4/7 tests reactive) and 1,087 (54.5%) were true negatives (≥4/7 tests nonreactive). Positive agreement ranged from 86.1% (83.7 to 88.2%) for FTA-ABS to 99.7% (99.0 to 99.9%) for Advia-Centaur CIA; negative agreement ranged from 86.3% (84.1 to 88.2%) for Trep-Sure EIA to 100% for TP-PA (99.6 to 100%). Increasing signal strength values correlated with increasing reactivity of confirmatory testing (
< 0.0001 for all automated immunoassays by Cochran-Armitage test for trend). All automated immunoassays had signal strength cutoffs corresponding to ≥4/7 reactive treponemal tests. BioPlex MBIA and Liaison CIA had signal strength cutoffs correlating with ≥99% and 100% TP-PA reactivity, respectively. The Advia-Centaur CIA and Trep-Sure EIA had signal strength cutoffs correlating with at least 95% TP-PA reactivity. All automated immunoassays had signal strength cutoffs correlating with at least 95% FTA-ABS reactivity. Assuming that a 95% level of confirmation is adequate, these signal strength values can be used in lieu of confirmatory testing with TP-PA and FTA-ABS. |
|---|---|
| Bibliographie: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
| ISSN: | 1098-660X 1098-660X |
| DOI: | 10.1128/JCM.01165-17 |