The effect of a next generation factor VIII mimetic bispecific antibody (Mim8) on assays of factor VIII activity and thrombin generation
Mim8 is a next generation bispecific antibody developed for the prophylactic treatment of hemophilia A. The sensitivity of activated plasma thromboplastin time (APTT), assays measuring factor VIII activity (FVIII:C) and thrombin generation to plasma containing Mim8 was assessed. Congenital severe he...
Gespeichert in:
| Veröffentlicht in: | Journal of thrombosis and haemostasis Jg. 21; H. 3; S. 480 - 487 |
|---|---|
| Hauptverfasser: | , , |
| Format: | Journal Article |
| Sprache: | Englisch |
| Veröffentlicht: |
England
Elsevier Inc
01.03.2023
|
| Schlagworte: | |
| ISSN: | 1538-7836, 1538-7836 |
| Online-Zugang: | Volltext |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Zusammenfassung: | Mim8 is a next generation bispecific antibody developed for the prophylactic treatment of hemophilia A. The sensitivity of activated plasma thromboplastin time (APTT), assays measuring factor VIII activity (FVIII:C) and thrombin generation to plasma containing Mim8 was assessed.
Congenital severe hemophilia A plasma was spiked with Mim8 at 0 μg/mL to 20 μg/mL. APTT was measured with 4 reagents, one-stage FVIII with 9 reagents, and chromogenic FVIII with 6 assays. Thrombin generation was assessed in a low tissue factor system.
At 1-μg/mL Mim8, the APTT was shortened to within normal limits and one-stage FVIII:C was >1.00 IU/mL with all APTT reagents. Modified one-stage assays calibrated with Mim8 reference material calibrated recovered within 20% of the target Mim8 concentration with most APTT reagents. Factor VIII:C of bovine only chromogenic assays was <0.04 IU/mL at all Mim8 concentrations. Factor VIII:C of human only chromogenic assay was >4.00 IU/mL at 20-μg/mL Mim8. Factor VIII:C of hybrid bovine FX, human FIXa chromogenic assays ranged from 0.076 to >3.00 IU/mL at 20-μg/mL Mim8. Normal thrombin generation was restored at 5-μg/mL Mim8.
APTT-based assays are sensitive to Mim8 and should not be performed in the presence of the drug. Chromogenic assays containing human proteins or hybrid human/bovine proteins demonstrated variable sensitivity to Mim8. Bovine only chromogenic assays were largely insensitive to the presence of Mim8. Thrombin generation normalized at increased Mim8 concentrations. Modified one-stage and chromogenic assays could be used to quantify the Mim8 concentration in plasma.
•Mim8 is a next generation bispecific antibody for the prophylactic treatment of hemophilia A.•Measurement of factor VIII (FVIII) activity and thrombin generation was performed in plasma spiked with Mim8.•Modified Mim8 reference calibrated one-stage FVIII assays accurately measured the drug concentration.•Chromogenic FVIII assays varied in their sensitivity to Mim8. |
|---|---|
| Bibliographie: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| ISSN: | 1538-7836 1538-7836 |
| DOI: | 10.1016/j.jtha.2022.12.023 |