Combination of “generalized Trotter operator splitting” and “quadratic adaptive algorithm” method for tradeoff among speedup, stability, and accuracy in the Markov chain model of sodium ion channels in the ventricular cell model

The fast hybrid operator splitting (HOS) and stable uniformization (UNI) methods have been proposed to save computation cost and enhance stability for Markov chain model in cardiac cell simulations. Moreover, Chen-Chen-Luo’s quadratic adaptive algorithm (CCL) combined with HOS or UNI was used to imp...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Medical & biological engineering & computing Ročník 58; číslo 9; s. 2131 - 2141
Hlavní autori: Chen, Xing-Ji, Luo, Ching-Hsing, Chen, Min-Hung
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: Berlin/Heidelberg Springer Berlin Heidelberg 01.09.2020
Springer Nature B.V
Predmet:
ISSN:0140-0118, 1741-0444, 1741-0444
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:The fast hybrid operator splitting (HOS) and stable uniformization (UNI) methods have been proposed to save computation cost and enhance stability for Markov chain model in cardiac cell simulations. Moreover, Chen-Chen-Luo’s quadratic adaptive algorithm (CCL) combined with HOS or UNI was used to improve the tradeoff between speedup and stability, but without considering accuracy. To compromise among stability, acceleration, and accuracy, we propose a generalized Trotter operator splitting (GTOS) method combined with CCL independent of the asymptotic property of a particular ion-channel model. Due to the accuracy underestimation of the mixed root mean square error (MRMSE) method, threshold root mean square error (TRMSE) is proposed to evaluate computation accuracy. With the fixed time-step RK4 as a reference, the second-order GTOS combined with CCL (30.8-fold speedup) for the wild-type Markov chain model with nine states (WT-9 model) or (7.4-fold) for the wild-type Markov chain model with eight states (WT-8 model) is faster than UNI combined with CCL (15.6-fold) for WT-9 model or (1.2-fold) for WT-8 model, separately. Besides, the second-order GTOS combined with CCL has 3.81% TRMSE for WT-9 model or 4.32% TRMSE for WT-8 model more accurate than 72.43% TRMSE for WT-9 model or 136.17% TRMSE for WT-8 model of HOS combined with CCL. To compromise speedup and accuracy, low-order GTOS combined with CCL is suggested to have the advantages of high precision and low computation cost. For high-accuracy requirements, high-order GTOS combined with CCL is recommended. Graphical abstract
Bibliografia:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0140-0118
1741-0444
1741-0444