sMLACF: a generalized expectation-maximization algorithm for TOF-PET to reconstruct the activity and attenuation simultaneously
The 'simultaneous maximum-likelihood attenuation correction factors' (sMLACF) algorithm presented here, is an iterative algorithm to calculate the maximum-likelihood estimate of the activity λ and the attenuation factors a in time-of-flight positron emission tomography, and this from emiss...
Uložené v:
| Vydané v: | Physics in medicine & biology Ročník 62; číslo 21; s. 8283 |
|---|---|
| Hlavní autori: | , |
| Médium: | Journal Article |
| Jazyk: | English |
| Vydavateľské údaje: |
England
12.10.2017
|
| Predmet: | |
| ISSN: | 1361-6560, 1361-6560 |
| On-line prístup: | Zistit podrobnosti o prístupe |
| Tagy: |
Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
|
| Abstract | The 'simultaneous maximum-likelihood attenuation correction factors' (sMLACF) algorithm presented here, is an iterative algorithm to calculate the maximum-likelihood estimate of the activity λ and the attenuation factors a in time-of-flight positron emission tomography, and this from emission data only. Hence sMLACF is an alternative to the MLACF algorithm. sMLACF is derived using the generalized expectation-maximization principle by introducing an appropriate set of complete data. The resulting iteration step yields a simultaneous update of λ and a which, in addition, enforces in a natural way the constraints [Formula: see text] where [Formula: see text] is a fixed lower bound that ensures the boundedness of the reconstructed activities. Some properties-like the monotonic increase of the likelihood and the asymptotic regularity of the estimated [Formula: see text]-of sMLACF are proven. Comparison of sMLACF with MLACF for two data sets reveals that both algorithms show very similar results, although sMLACF converges slower. |
|---|---|
| AbstractList | The 'simultaneous maximum-likelihood attenuation correction factors' (sMLACF) algorithm presented here, is an iterative algorithm to calculate the maximum-likelihood estimate of the activity λ and the attenuation factors a in time-of-flight positron emission tomography, and this from emission data only. Hence sMLACF is an alternative to the MLACF algorithm. sMLACF is derived using the generalized expectation-maximization principle by introducing an appropriate set of complete data. The resulting iteration step yields a simultaneous update of λ and a which, in addition, enforces in a natural way the constraints [Formula: see text] where [Formula: see text] is a fixed lower bound that ensures the boundedness of the reconstructed activities. Some properties-like the monotonic increase of the likelihood and the asymptotic regularity of the estimated [Formula: see text]-of sMLACF are proven. Comparison of sMLACF with MLACF for two data sets reveals that both algorithms show very similar results, although sMLACF converges slower. The 'simultaneous maximum-likelihood attenuation correction factors' (sMLACF) algorithm presented here, is an iterative algorithm to calculate the maximum-likelihood estimate of the activity λ and the attenuation factors a in time-of-flight positron emission tomography, and this from emission data only. Hence sMLACF is an alternative to the MLACF algorithm. sMLACF is derived using the generalized expectation-maximization principle by introducing an appropriate set of complete data. The resulting iteration step yields a simultaneous update of λ and a which, in addition, enforces in a natural way the constraints [Formula: see text] where [Formula: see text] is a fixed lower bound that ensures the boundedness of the reconstructed activities. Some properties-like the monotonic increase of the likelihood and the asymptotic regularity of the estimated [Formula: see text]-of sMLACF are proven. Comparison of sMLACF with MLACF for two data sets reveals that both algorithms show very similar results, although sMLACF converges slower.The 'simultaneous maximum-likelihood attenuation correction factors' (sMLACF) algorithm presented here, is an iterative algorithm to calculate the maximum-likelihood estimate of the activity λ and the attenuation factors a in time-of-flight positron emission tomography, and this from emission data only. Hence sMLACF is an alternative to the MLACF algorithm. sMLACF is derived using the generalized expectation-maximization principle by introducing an appropriate set of complete data. The resulting iteration step yields a simultaneous update of λ and a which, in addition, enforces in a natural way the constraints [Formula: see text] where [Formula: see text] is a fixed lower bound that ensures the boundedness of the reconstructed activities. Some properties-like the monotonic increase of the likelihood and the asymptotic regularity of the estimated [Formula: see text]-of sMLACF are proven. Comparison of sMLACF with MLACF for two data sets reveals that both algorithms show very similar results, although sMLACF converges slower. |
| Author | Defrise, Michel Salvo, Koen |
| Author_xml | – sequence: 1 givenname: Koen surname: Salvo fullname: Salvo, Koen organization: Department of Medical Imaging and Physical Sciences, Vrije Universiteit Brussel, B-1090, Brussels, Belgium – sequence: 2 givenname: Michel surname: Defrise fullname: Defrise, Michel |
| BackLink | https://www.ncbi.nlm.nih.gov/pubmed/28753134$$D View this record in MEDLINE/PubMed |
| BookMark | eNpNkM1PAjEQxRuDkQ-9ezI9elndbunHeiME1ASDBzxvhu4s1OwHtl0DXPzXJYLG08x7-eVl3vRJp25qJOSaxXcs1vqecckiKWR8D6AThDPS-7M6__Yu6Xv_HseM6WR4QbqJVoIzPuyRL_8yG42nDxToCmt0UNo95hS3GzQBgm3qqIKtrez-R1AoV42zYV3RonF0MZ9Gr5MFDQ11aJraB9eaQMMaKZhgP23YUahzCiFg3R4TvK3aMkCNTevL3SU5L6D0eHWaA_I2nSzGT9Fs_vg8Hs0iw7kMEVd5GhuRF0OQUqWSFRrSJaLgCc8VV4fuChIjNDA0QhqZppDnS8UUskIVLBmQ22PuxjUfLfqQVdYbLMvjIRlLk6FIYy3iA3pzQttlhXm2cbYCt8t-n5Z8A7PBc3Y |
| CitedBy_id | crossref_primary_10_1002_mp_15376 crossref_primary_10_1088_1361_6560_aaa8a6 crossref_primary_10_1186_s40658_019_0254_y |
| ContentType | Journal Article |
| DBID | CGR CUY CVF ECM EIF NPM 7X8 |
| DOI | 10.1088/1361-6560/aa82ea |
| DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic |
| DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
| DatabaseTitleList | MEDLINE MEDLINE - Academic |
| Database_xml | – sequence: 1 dbid: NPM name: PubMed url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: 7X8 name: MEDLINE - Academic url: https://search.proquest.com/medline sourceTypes: Aggregation Database |
| DeliveryMethod | no_fulltext_linktorsrc |
| Discipline | Medicine Biology Physics |
| EISSN | 1361-6560 |
| ExternalDocumentID | 28753134 |
| Genre | Journal Article |
| GroupedDBID | --- -DZ -~X 123 1JI 4.4 5B3 5RE 5VS 5ZH 7.M 7.Q AAGCD AAJIO AAJKP AALHV AATNI ABCXL ABHWH ABJNI ABLJU ABQJV ABVAM ACAFW ACGFS ACHIP AEFHF AENEX AFYNE AKPSB ALMA_UNASSIGNED_HOLDINGS AOAED ASPBG ATQHT AVWKF AZFZN CBCFC CEBXE CGR CJUJL CRLBU CS3 CUY CVF DU5 EBS ECM EDWGO EIF EJD EMSAF EPQRW EQZZN F5P HAK IHE IJHAN IOP IZVLO KOT LAP M45 N5L N9A NPM NT- NT. P2P PJBAE R4D RIN RNS RO9 ROL RPA SY9 TN5 UCJ W28 XPP 7X8 ADEQX AEINN |
| ID | FETCH-LOGICAL-c336t-37d90c5df4a667961f8a9bee5323d7372ea7a2c58a1ec56c699addb717e1f7f12 |
| IEDL.DBID | 7X8 |
| ISICitedReferencesCount | 6 |
| ISICitedReferencesURI | http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000413137000006&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| ISSN | 1361-6560 |
| IngestDate | Fri Sep 05 10:21:15 EDT 2025 Thu Jan 02 23:11:05 EST 2025 |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 21 |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-c336t-37d90c5df4a667961f8a9bee5323d7372ea7a2c58a1ec56c699addb717e1f7f12 |
| Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| PMID | 28753134 |
| PQID | 1924590850 |
| PQPubID | 23479 |
| ParticipantIDs | proquest_miscellaneous_1924590850 pubmed_primary_28753134 |
| PublicationCentury | 2000 |
| PublicationDate | 2017-Oct-12 |
| PublicationDateYYYYMMDD | 2017-10-12 |
| PublicationDate_xml | – month: 10 year: 2017 text: 2017-Oct-12 day: 12 |
| PublicationDecade | 2010 |
| PublicationPlace | England |
| PublicationPlace_xml | – name: England |
| PublicationTitle | Physics in medicine & biology |
| PublicationTitleAlternate | Phys Med Biol |
| PublicationYear | 2017 |
| SSID | ssj0011824 |
| Score | 2.2629185 |
| Snippet | The 'simultaneous maximum-likelihood attenuation correction factors' (sMLACF) algorithm presented here, is an iterative algorithm to calculate the... |
| SourceID | proquest pubmed |
| SourceType | Aggregation Database Index Database |
| StartPage | 8283 |
| SubjectTerms | Algorithms Female Humans Image Processing, Computer-Assisted - methods Likelihood Functions Phantoms, Imaging Positron-Emission Tomography - methods Thorax - diagnostic imaging |
| Title | sMLACF: a generalized expectation-maximization algorithm for TOF-PET to reconstruct the activity and attenuation simultaneously |
| URI | https://www.ncbi.nlm.nih.gov/pubmed/28753134 https://www.proquest.com/docview/1924590850 |
| Volume | 62 |
| WOSCitedRecordID | wos000413137000006&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| hasFullText | |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV27TsMwFLWAAmLhUd4vGYnVah0nTsKCKkTEQEuHgrpFjh-lUpsWUhCw8Ov4xoFOSEgsGSxFsRz7-lyf63MQOvfDpie1jAjjhhOfSkkEVwouu-vI17HxS0b34TbsdKJ-P-5WB25FVVb5HRPLQK0mEs7IG5AogD930LycPhFwjQJ2tbLQWEQ1ZqEMlHSF_TmLYLGzM7XllIDITEVT2oXV-GlrCBF5WvwOMMuNJtn4bxc30XoFMXHLzYkttKDzOlpxppPvdbTaruh021jWf8piG30W7dvWVXKBBR44Ierhh1YY9P-lI-vJWLwNx9WtTSxGA_vl2eMYW9CLe3cJ6V738GyCywTbidJiiy0x3JsAewoscoVByzN32uK4GEIto8j15KUYve-g--S6d3VDKm8GIhnjMxuXVNyUgTK-4HAURU0k4kzrgHlMgfWNFqHwZBAJqmXAJY9jG0kzmzxqakJDvV20lE9yvY9wRGVsbK4cZkb5nOnYtxiES5pR1VQZyw7Q2fdwp3buA6HhOpfOB_wA7bl_lk6dSEfqQSJGmX_4h7eP0JoHu3VZqHKMasaufH2CluXrbFg8n5aTyj473fYXGl_YjA |
| linkProvider | ProQuest |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=sMLACF%3A+a+generalized+expectation-maximization+algorithm+for+TOF-PET+to+reconstruct+the+activity+and+attenuation+simultaneously&rft.jtitle=Physics+in+medicine+%26+biology&rft.au=Salvo%2C+Koen&rft.au=Defrise%2C+Michel&rft.date=2017-10-12&rft.eissn=1361-6560&rft.volume=62&rft.issue=21&rft.spage=8283&rft_id=info:doi/10.1088%2F1361-6560%2Faa82ea&rft_id=info%3Apmid%2F28753134&rft_id=info%3Apmid%2F28753134&rft.externalDocID=28753134 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1361-6560&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1361-6560&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1361-6560&client=summon |