Detecting defects in geomembranes of landfill liner systems: durable electrical method

Monitoring the geomembrane's integrity becomes an essential part of recent quality assurance and quality control programs in order to guarantee an optimal performance of liner barrier. However, the existing electrical methods of leak detection for landfill barriers are generally expensive and a...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:International journal of geotechnical engineering Ročník 7; číslo 2; s. 130 - 135
Hlavní autori: Ben Othmen, A, Bouassida, M
Médium: Journal Article
Jazyk:English
Vydavateľské údaje: Taylor & Francis 01.04.2013
Predmet:
ISSN:1938-6362, 1939-7879
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Popis
Shrnutí:Monitoring the geomembrane's integrity becomes an essential part of recent quality assurance and quality control programs in order to guarantee an optimal performance of liner barrier. However, the existing electrical methods of leak detection for landfill barriers are generally expensive and allow only a temporary detection of geomembrane damages. Authors suggest a novel permanent electrical leak detection method for landfill barrier. Compared to existing methods, the proposed electrical circuits method (ECM) which is based on the installation of large parallel electrical circuits over the landfill site appears more cost effective and more affordable.
ISSN:1938-6362
1939-7879
DOI:10.1179/1938636213Z.00000000013