Monitoring the geomembrane's integrity becomes an essential part of recent quality assurance and quality control programs in order to guarantee an optimal performance of liner barrier. However, the existing electrical methods of leak detection for landfill barriers are generally expensive and a...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:International journal of geotechnical engineering Ročník 7; číslo 2; s. 130 - 135
Hlavní autoři: Ben Othmen, A, Bouassida, M
Médium: Journal Article
Jazyk:angličtina
Vydáno: Taylor & Francis 01.04.2013
Témata:
ISSN:1938-6362, 1939-7879
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:Monitoring the geomembrane's integrity becomes an essential part of recent quality assurance and quality control programs in order to guarantee an optimal performance of liner barrier. However, the existing electrical methods of leak detection for landfill barriers are generally expensive and allow only a temporary detection of geomembrane damages. Authors suggest a novel permanent electrical leak detection method for landfill barrier. Compared to existing methods, the proposed electrical circuits method (ECM) which is based on the installation of large parallel electrical circuits over the landfill site appears more cost effective and more affordable.