Phase retrieval based on a total‐variation‐regularized Poisson model for X‐ray ptychographic imaging of low‐contrast objects
Hard X‐ray ptychography has become an indispensable tool for observing the microscopic structure of a thick specimen. It measures diffraction patterns by scanning an X‐ray beam and visualizes the complex‐valued refractive index of the specimen by a computational reconstruction called phase retrieval...
Uloženo v:
| Vydáno v: | Journal of applied crystallography Ročník 55; číslo 4; s. 978 - 992 |
|---|---|
| Hlavní autoři: | , |
| Médium: | Journal Article |
| Jazyk: | angličtina |
| Vydáno: |
5 Abbey Square, Chester, Cheshire CH1 2HU, England
International Union of Crystallography
01.08.2022
Blackwell Publishing Ltd |
| Témata: | |
| ISSN: | 1600-5767, 0021-8898, 1600-5767 |
| On-line přístup: | Získat plný text |
| Tagy: |
Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
|
| Shrnutí: | Hard X‐ray ptychography has become an indispensable tool for observing the microscopic structure of a thick specimen. It measures diffraction patterns by scanning an X‐ray beam and visualizes the complex‐valued refractive index of the specimen by a computational reconstruction called phase retrieval. The quality of imaging is dependent on the used phase‐retrieval algorithm, especially when the intensity of the diffraction patterns in the high‐spatial‐frequency range is low and/or when the spatial overlap of the illumination area is small. In this paper, a phase‐retrieval algorithm, AMPAM, based on the Poisson model and total variation (TV) is proposed. It applies alternating minimization using primal‐dual splitting and gradient‐descent algorithms to compute the result without matrix inversion. The imaging capability of the proposed algorithm from low‐dose and/or sparsely scanned data was investigated by numerical simulations. The proposed algorithm was compared with ADPr, which is the state‐of‐the‐art algorithm based on the TV‐regularized Poisson model. The results indicated that AMPAM can provide good‐quality images with a computational cost 7–11 times less than ADPr. In addition, ink toner and macroporous silica particles were imaged at SPring‐8 BL24XU to confirm the applicability of the algorithm to actual measurements.
This paper presents a phase‐retrieval algorithm for ptychography, named AMPAM. The imaging capability of AMPAM was investigated by numerical simulations and measurements performed at SPring‐8. |
|---|---|
| Bibliografie: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 |
| ISSN: | 1600-5767 0021-8898 1600-5767 |
| DOI: | 10.1107/S1600576722005234 |