Explore Electrotactile Parametric Properties Using an Electrical Stimulation System

Influenced by multiple factors, to understand electrotactile properties is challenging but significant in comparing individual differences, parameters control and coding, and model studies. However, the inadequacy of measurement systems and methods limits the application and development of electrota...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:IEEE sensors journal Ročník 22; číslo 7; s. 7053 - 7062
Hlavní autoři: Zhou, Ziliang, Yang, Yicheng, Zeng, Jia, Wang, Xiaoxin, Liu, Honghai
Médium: Journal Article
Jazyk:angličtina
Vydáno: New York IEEE 01.04.2022
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Témata:
ISSN:1530-437X, 1558-1748
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:Influenced by multiple factors, to understand electrotactile properties is challenging but significant in comparing individual differences, parameters control and coding, and model studies. However, the inadequacy of measurement systems and methods limits the application and development of electrotactile feedback. This study focuses on the exploration of parametric properties using an electrical stimulation system (ESS) via innovative measurement methods and electrotactile control. A 6-channel portable stimulator and a graphical user interface (GUI) with interactive algorithms have been designed. Modified staircase method, bisection and parametric-random algorithms are developed for the psychophysical measurement of detection thresholds (DT), pain threshold (PT), just-noticeable difference (JND), parameter-intensity properties (PIP) and sensitivity index (SI). The system performance is verified by conducting four sub-experiments on eight subjects. Bisection algorithm is proved to be more robust (p < 0.05). JND measurement based on bisection algorithm achieves 50% efficiency improvement over traditional methods. The individual differences and sensitivities are quantified by SI. The JND and PIP measurement results indicate the potential for iso-resolution and iso-intensity control in information coding as well as parameter-intensity modelling. The results of this paper could provide a basis for tactile information encoding as well as an experimental platform for investigating perception mechanism.
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:1530-437X
1558-1748
DOI:10.1109/JSEN.2022.3152185