Unit Template Synchronous Reference Frame Theory Based Control Algorithm for DSTATCOM
This article proposes new and simplified unit templates instead of standard phase locked loop (PLL) for Synchronous Reference Frame Theory Control Algorithm (SRFT). The extraction of synchronizing components (sinθ and cosθ) for parks and inverse parks transformation using standard PLL takes more exe...
Uložené v:
| Vydané v: | Journal of the Institution of Engineers (India). Series B, Electrical Engineering, Electronics and telecommunication engineering, Computer engineering Ročník 95; číslo 2; s. 135 - 141 |
|---|---|
| Hlavní autori: | , , |
| Médium: | Journal Article |
| Jazyk: | English |
| Vydavateľské údaje: |
India
Springer India
01.04.2014
|
| Predmet: | |
| ISSN: | 2250-2106, 2250-2114 |
| On-line prístup: | Získať plný text |
| Tagy: |
Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
|
| Abstract | This article proposes new and simplified unit templates instead of standard phase locked loop (PLL) for Synchronous Reference Frame Theory Control Algorithm (SRFT). The extraction of synchronizing components (sinθ and cosθ) for parks and inverse parks transformation using standard PLL takes more execution time. This execution time in control algorithm delays the extraction of reference source current generation. The standard PLL not only takes more execution time but also increases the reactive power burden on the Distributed Static Compensator (DSTATCOM). This work proposes a unit template based SRFT control algorithm for four-leg insulated gate bipolar transistor based voltage source converter for DSTATCOM in distribution systems. This will reduce the execution time and reactive power burden on the DSTATCOM. The proposed DSTATCOM suppress harmonics, regulates the terminal voltage along with neutral current compensation. The DSTATCOM in distribution systems with proposed control algorithm is modeled and simulated using MATLAB using SIMULINK and Simpower systems toolboxes. |
|---|---|
| AbstractList | This article proposes new and simplified unit templates instead of standard phase locked loop (PLL) for Synchronous Reference Frame Theory Control Algorithm (SRFT). The extraction of synchronizing components (sinθ and cosθ) for parks and inverse parks transformation using standard PLL takes more execution time. This execution time in control algorithm delays the extraction of reference source current generation. The standard PLL not only takes more execution time but also increases the reactive power burden on the Distributed Static Compensator (DSTATCOM). This work proposes a unit template based SRFT control algorithm for four-leg insulated gate bipolar transistor based voltage source converter for DSTATCOM in distribution systems. This will reduce the execution time and reactive power burden on the DSTATCOM. The proposed DSTATCOM suppress harmonics, regulates the terminal voltage along with neutral current compensation. The DSTATCOM in distribution systems with proposed control algorithm is modeled and simulated using MATLAB using SIMULINK and Simpower systems toolboxes. |
| Author | Bangarraju, J. Jayalaxmi, A. Rajagopal, V. |
| Author_xml | – sequence: 1 givenname: J. surname: Bangarraju fullname: Bangarraju, J. email: rajujbr@gmail.com organization: Department of Electrical and Electronics Engineering, Padmasri Dr. B.V. Raju Institute of Technology – sequence: 2 givenname: V. surname: Rajagopal fullname: Rajagopal, V. organization: Department of Electrical and Electronics Engineering, Padmasri Dr. B.V. Raju Institute of Technology – sequence: 3 givenname: A. surname: Jayalaxmi fullname: Jayalaxmi, A. organization: Department of Electrical and Electronics Engineering, JNTU College of Engineering, Hyderabad |
| BookMark | eNp9kMFuwjAMQKOJSWOMD9gtP9DNSdOmHFk3tklMSKOcozQkUNQmKCmH_v2CmHbYgYttWX6W_e7RyDqrEXok8EQA-HNgAClJgLAEoODJcIPGlGaQUELY6K-G_A5NQzgAAClYRmezMdpsbNPjSnfHVvYarwer9t5Zdwr4WxvttVUaL7zsNK722vkBv8igt7h0tveuxfN253zT7ztsnMev62pelauvB3RrZBv09DdP0GbxVpUfyXL1_lnOl4mikA5JUacyZzQ3KS2yDDiva5NTVUhVKOCKb2MJMZiaaBJbmQJWGFrXLNNcsTqdIH7Zq7wLwWsjVNPLvjkfJ5tWEBBnQeIiSERB4ixIDJEk_8ijbzrph6sMvTAhztqd9uLgTt7GB69AP1TdeuQ |
| CitedBy_id | crossref_primary_10_1007_s12008_022_00925_x crossref_primary_10_1080_01430750_2022_2128413 crossref_primary_10_1007_s12647_023_00734_x crossref_primary_10_1007_s13369_021_05559_x crossref_primary_10_1007_s40031_015_0206_4 crossref_primary_10_23919_CJEE_2022_000016 crossref_primary_10_1016_j_etran_2020_100066 crossref_primary_10_1080_1448837X_2017_1407015 |
| Cites_doi | 10.1109/TPEL.2007.897115 10.1109/TPWRD.2005.844281 10.1109/TPEL.2007.911779 10.1049/iet-pel:20070171 10.1109/TPWRD.2008.923053 10.1007/978-1-4615-1153-3 10.1109/TPEL.2008.2004273 10.1049/ip-epa:20030009 |
| ContentType | Journal Article |
| Copyright | The Institution of Engineers (India) 2014 |
| Copyright_xml | – notice: The Institution of Engineers (India) 2014 |
| DBID | AAYXX CITATION |
| DOI | 10.1007/s40031-014-0087-y |
| DatabaseName | CrossRef |
| DatabaseTitle | CrossRef |
| DatabaseTitleList | |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Engineering |
| EISSN | 2250-2114 |
| EndPage | 141 |
| ExternalDocumentID | 10_1007_s40031_014_0087_y |
| GroupedDBID | -EM 06D 0R~ 203 29~ 30V 4.4 406 408 96X AAAVM AACDK AAHNG AAIAL AAJBT AAJKR AANZL AARHV AARTL AASML AATNV AATVU AAUYE AAWCG AAYIU AAYQN AAYTO AAZMS ABAKF ABDZT ABECU ABFTV ABJNI ABJOX ABKCH ABMQK ABQBU ABTEG ABTHY ABTKH ABTMW ABXPI ACAOD ACCUX ACDTI ACGFS ACHSB ACIWK ACKNC ACMLO ACOKC ACPIV ACZOJ ADHHG ADHIR ADINQ ADKNI ADKPE ADRFC ADTPH ADURQ ADYFF ADZKW AEBTG AEFQL AEGNC AEJHL AEJRE AEMSY AEOHA AEPYU AESKC AETCA AEVLU AEXYK AFBBN AFLOW AFQWF AFWTZ AFZKB AGAYW AGDGC AGMZJ AGQEE AGQMX AGRTI AGWZB AGYKE AHAVH AHBYD AHKAY AHSBF AIAKS AIGIU AIIXL AILAN AITGF AJBLW AJRNO AJZVZ AKLTO ALFXC ALMA_UNASSIGNED_HOLDINGS AMKLP AMXSW AMYLF AMYQR ANMIH AUKKA AXYYD AYJHY BGNMA CSCUP DNIVK DPUIP EBLON EBS EIOEI EJD ESBYG FERAY FIGPU FINBP FNLPD FRRFC FSGXE FYJPI GGCAI GGRSB GJIRD GQ7 HMJXF HRMNR HZ~ I0C IKXTQ IWAJR IXD J-C JBSCW JZLTJ KOV LLZTM M4Y NPVJJ NQJWS NU0 O9- O93 O9G O9J PT4 RIG RLLFE ROL RSV SEG SHX SISQX SJYHP SNE SNPRN SNX SOHCF SOJ SPISZ SRMVM SSLCW STPWE TSG UG4 UOJIU UTJUX UZXMN VFIZW W48 Z7Y Z7Z ZMTXR AAYXX ABBRH ABDBE ABFSG ABJCF ABRTQ ACSTC AEZWR AFDZB AFFHD AFHIU AFKRA AFOHR AHPBZ AHWEU AIXLP ATHPR AYFIA BENPR BGLVJ CCPQU CITATION HCIFZ M7S PHGZM PHGZT PQGLB PTHSS |
| ID | FETCH-LOGICAL-c203y-8b3a6426f32855077bbf62c8ac8c07c7dc8a0dc8fb1e18c05c048f2bb45e7c4b3 |
| IEDL.DBID | RSV |
| ISSN | 2250-2106 |
| IngestDate | Sat Nov 29 05:52:06 EST 2025 Tue Nov 18 21:28:55 EST 2025 Fri Feb 21 02:33:04 EST 2025 |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 2 |
| Keywords | Voltage source converter Harmonics Insulated gate bipolar transistor Synchronous Reference Frame Theory Power quality DSTATCOM Phase locked loop |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-c203y-8b3a6426f32855077bbf62c8ac8c07c7dc8a0dc8fb1e18c05c048f2bb45e7c4b3 |
| PageCount | 7 |
| ParticipantIDs | crossref_citationtrail_10_1007_s40031_014_0087_y crossref_primary_10_1007_s40031_014_0087_y springer_journals_10_1007_s40031_014_0087_y |
| PublicationCentury | 2000 |
| PublicationDate | 20140400 2014-4-00 |
| PublicationDateYYYYMMDD | 2014-04-01 |
| PublicationDate_xml | – month: 4 year: 2014 text: 20140400 |
| PublicationDecade | 2010 |
| PublicationPlace | India |
| PublicationPlace_xml | – name: India |
| PublicationSubtitle | Electrical, Electronics & Telecommunication and Computer Engineering |
| PublicationTitle | Journal of the Institution of Engineers (India). Series B, Electrical Engineering, Electronics and telecommunication engineering, Computer engineering |
| PublicationTitleAbbrev | J. Inst. Eng. India Ser. B |
| PublicationYear | 2014 |
| Publisher | Springer India |
| Publisher_xml | – name: Springer India |
| References | DuganRCMcGranaghanMFBeatyHWElectrical power systems quality1996New YorkMcGraw-Hill B. Singh, P. Jayaprakash, D.P. Kothari, A T-connected transformer three-leg VSC based DSTATCOM for power quality improvement. IEEE Trans. Power Electron. 23(6), 2710–2718 (2008) RaoUKMishraMKGhoshAControl strategies for load compensation using instantaneous symmetrical component theory under different supply voltagesIEEE Trans. Power Delivery20082342310231710.1109/TPWRD.2008.923053 JouHLWuKDWuJCLiCHHuangMSNovel power converter topology for three-phase four-wire hybrid power filterIET Power Electron20081116417310.1049/iet-pel:20070171 AkagiHOgasawaraSKimHThe theory of instantaneous power in three-phase four-wire systems: a comprehensive approachProc. IEEE Ind. Appl. Conf.19991431439 SinghBNSinghBChandraAAl-HaddadKDesign and digital implementation of active power filters with power balance theoryIEE Proc.2005152511491160 JouH-LWuKDJ-CWuChiangWJA three-phase four-wire power filter comprising a three-phase three-wire active filter and a zig–zag transformerIEEE Trans. Power Electron.200823125225910.1109/TPEL.2007.911779 GhoshALedwichGPower quality enhancement using custom power devices2002LondonKluwer Academic Publishers10.1007/978-1-4615-1153-3 AkagiYKNabaeAGeneralized theory of the instantaneous reactive power in three-phase circuitsProc. IEEE IPEC198383821827 FugitaHAkagiHVoltage-regulation performance of a shunt active filter intended for installation on a power distribution systemIEEE Trans. Power Electron.20072211046105310.1109/TPEL.2007.897115 VazquezJRSalmeronPActive power filter control using neural network technologiesProc. Inst. Electr. Eng. Elect. Power Appl.2003150213914510.1049/ip-epa:20030009 JouH-LWuJ-CWuK-DChiangW-JChenY-HAnalysis of zig–zag transformer applying in the three-phase four-wire distribution power systemIEEE Trans. Power Deliv.20052021168117310.1109/TPWRD.2005.844281 FuchsEFMausoumMd ASPower quality in power systems and electrical machines2008LondonElsevier Academic Press S. Bhattacharya, D. Diwan, Synchronous frame based controller implementation for a hybrid series active filter system. Proceedings of the IEEE Industry Applications Society Meeting (1995), pp. 2531–2540 M.D. Bhattacharya, B. Benerjee, Synchronous reference frame harmonic isolator using series active filter. Fourth European Power Electronic Conference, Florence, vol. 3 (1991), pp. 30–35 IEEE recommended practices and requirements for harmonics control in electrical power systems, IEEE Std. 519, (1992) 87_CR13 H-L Jou (87_CR5) 2008; 23 87_CR12 UK Rao (87_CR14) 2008; 23 HL Jou (87_CR8) 2008; 1 87_CR3 H-L Jou (87_CR6) 2005; 20 YK Akagi (87_CR9) 1983; 83 A Ghosh (87_CR2) 2002 EF Fuchs (87_CR7) 2008 H Akagi (87_CR10) 1999; 1 RC Dugan (87_CR1) 1996 JR Vazquez (87_CR16) 2003; 150 BN Singh (87_CR15) 2005; 152 H Fugita (87_CR4) 2007; 22 87_CR11 |
| References_xml | – reference: FuchsEFMausoumMd ASPower quality in power systems and electrical machines2008LondonElsevier Academic Press – reference: B. Singh, P. Jayaprakash, D.P. Kothari, A T-connected transformer three-leg VSC based DSTATCOM for power quality improvement. IEEE Trans. Power Electron. 23(6), 2710–2718 (2008) – reference: M.D. Bhattacharya, B. Benerjee, Synchronous reference frame harmonic isolator using series active filter. Fourth European Power Electronic Conference, Florence, vol. 3 (1991), pp. 30–35 – reference: SinghBNSinghBChandraAAl-HaddadKDesign and digital implementation of active power filters with power balance theoryIEE Proc.2005152511491160 – reference: IEEE recommended practices and requirements for harmonics control in electrical power systems, IEEE Std. 519, (1992) – reference: JouH-LWuJ-CWuK-DChiangW-JChenY-HAnalysis of zig–zag transformer applying in the three-phase four-wire distribution power systemIEEE Trans. Power Deliv.20052021168117310.1109/TPWRD.2005.844281 – reference: JouH-LWuKDJ-CWuChiangWJA three-phase four-wire power filter comprising a three-phase three-wire active filter and a zig–zag transformerIEEE Trans. Power Electron.200823125225910.1109/TPEL.2007.911779 – reference: RaoUKMishraMKGhoshAControl strategies for load compensation using instantaneous symmetrical component theory under different supply voltagesIEEE Trans. Power Delivery20082342310231710.1109/TPWRD.2008.923053 – reference: AkagiYKNabaeAGeneralized theory of the instantaneous reactive power in three-phase circuitsProc. IEEE IPEC198383821827 – reference: AkagiHOgasawaraSKimHThe theory of instantaneous power in three-phase four-wire systems: a comprehensive approachProc. IEEE Ind. Appl. Conf.19991431439 – reference: S. Bhattacharya, D. Diwan, Synchronous frame based controller implementation for a hybrid series active filter system. Proceedings of the IEEE Industry Applications Society Meeting (1995), pp. 2531–2540 – reference: JouHLWuKDWuJCLiCHHuangMSNovel power converter topology for three-phase four-wire hybrid power filterIET Power Electron20081116417310.1049/iet-pel:20070171 – reference: GhoshALedwichGPower quality enhancement using custom power devices2002LondonKluwer Academic Publishers10.1007/978-1-4615-1153-3 – reference: VazquezJRSalmeronPActive power filter control using neural network technologiesProc. Inst. Electr. Eng. Elect. Power Appl.2003150213914510.1049/ip-epa:20030009 – reference: FugitaHAkagiHVoltage-regulation performance of a shunt active filter intended for installation on a power distribution systemIEEE Trans. Power Electron.20072211046105310.1109/TPEL.2007.897115 – reference: DuganRCMcGranaghanMFBeatyHWElectrical power systems quality1996New YorkMcGraw-Hill – volume-title: Electrical power systems quality year: 1996 ident: 87_CR1 – volume: 22 start-page: 1046 issue: 1 year: 2007 ident: 87_CR4 publication-title: IEEE Trans. Power Electron. doi: 10.1109/TPEL.2007.897115 – volume: 20 start-page: 1168 issue: 2 year: 2005 ident: 87_CR6 publication-title: IEEE Trans. Power Deliv. doi: 10.1109/TPWRD.2005.844281 – volume: 83 start-page: 821 year: 1983 ident: 87_CR9 publication-title: Proc. IEEE IPEC – volume: 23 start-page: 252 issue: 1 year: 2008 ident: 87_CR5 publication-title: IEEE Trans. Power Electron. doi: 10.1109/TPEL.2007.911779 – volume: 152 start-page: 1149 issue: 5 year: 2005 ident: 87_CR15 publication-title: IEE Proc. – volume: 1 start-page: 164 issue: 1 year: 2008 ident: 87_CR8 publication-title: IET Power Electron doi: 10.1049/iet-pel:20070171 – volume: 23 start-page: 2310 issue: 4 year: 2008 ident: 87_CR14 publication-title: IEEE Trans. Power Delivery doi: 10.1109/TPWRD.2008.923053 – volume-title: Power quality in power systems and electrical machines year: 2008 ident: 87_CR7 – volume-title: Power quality enhancement using custom power devices year: 2002 ident: 87_CR2 doi: 10.1007/978-1-4615-1153-3 – volume: 1 start-page: 431 year: 1999 ident: 87_CR10 publication-title: Proc. IEEE Ind. Appl. Conf. – ident: 87_CR11 – ident: 87_CR12 – ident: 87_CR3 – ident: 87_CR13 doi: 10.1109/TPEL.2008.2004273 – volume: 150 start-page: 139 issue: 2 year: 2003 ident: 87_CR16 publication-title: Proc. Inst. Electr. Eng. Elect. Power Appl. doi: 10.1049/ip-epa:20030009 |
| SSID | ssj0001845299 |
| Score | 1.9862607 |
| Snippet | This article proposes new and simplified unit templates instead of standard phase locked loop (PLL) for Synchronous Reference Frame Theory Control Algorithm... |
| SourceID | crossref springer |
| SourceType | Enrichment Source Index Database Publisher |
| StartPage | 135 |
| SubjectTerms | Communications Engineering Engineering Networks Original Contribution |
| Title | Unit Template Synchronous Reference Frame Theory Based Control Algorithm for DSTATCOM |
| URI | https://link.springer.com/article/10.1007/s40031-014-0087-y |
| Volume | 95 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVAVX databaseName: SpringerLINK Contemporary 1997-Present customDbUrl: eissn: 2250-2114 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0001845299 issn: 2250-2106 databaseCode: RSV dateStart: 20120301 isFulltext: true titleUrlDefault: https://link.springer.com/search?facet-content-type=%22Journal%22 providerName: Springer Nature |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LT8MwDLZgcIADb8R4KQdOoEh9ZG12HIOJAwzEOrRbtaTJmLR10zaQ-u9x-oJJgASXHqqkqmwn_hzbXwAumI9O05za-FbEKXNURPta21QzyfuW9nB_TCnz7_12m_d69ae8j3teVLsXKcl0py6b3ZgxQAx9GTU8ajRZhTX0dtzc1_Dcefk8WOEml2hgL5qqRTGk8Yps5ndfWfZHy8nQ1Me0tv_1dzuwlUNK0shsYBdWVLwHm1-IBveha6AlCdR4OkJsSTpJLA0pLkb9pGSaJS1Tp0WyZn1yjd4tIs2skJ00RoPJbLh4HRPEuOSmEzSC5uPDAXRbt0HzjuYXKlDpWG5CuXD7GG942nVSHjNfCO05qBTJpeVLPzL6wYcWtrLxVU3i-taOEKymfMmEewiVeBKrIyBMObLuyhpXTDJtS4FAzo48y9RWGdBUBasQayhztnFz6cUoLHmSU4mFKLHQSCxMqnBZTplmVBu_Db4q9BDmq27-8-jjP40-gQ0nVaSpzzmFymL2ps5gXb4vhvPZeWptH_CWzp4 |
| linkProvider | Springer Nature |
| linkToHtml | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LSwMxEB60CurBt1ifOXhSAvtId7fHWi0V2yp2K70tTTbRQl-0Vdh_72RfWlBBL3tYkmWZmWS-ycx8AbhgLjpNfWrjGqFHmSVD2lPKpIoJr2coB_fHmDK_4bZaXrdbfkz7uGdZtXuWkox36rzZjWkDxNCXUc2jRqNlWGHosDRh_lP7-fNgxdO5RA170VQNiiGNk2Uzv_vKoj9aTIbGPqa29a-_24bNFFKSSmIDO7AkR7uw8YVocA86GloSXw4nA8SWpB2NhCbFxaif5EyzpKbrtEjSrE-u0buFpJoUspPK4GU87c9fhwQxLrlp-xW_-tDch07t1q_WaXqhAhWWYUfU43YP4w1H2VbMY-ZyrhwLlSI8YbjCDbV-8KG4KU18VRK4vpXFOStJVzBuH0BhNB7JQyBMWqJsi5InmWDKFByBnBk6hq6t0qCpCEYm1kCkbOP60otBkPMkxxILUGKBllgQFeEynzJJqDZ-G3yV6SFIV93s59FHfxp9Dmt1v9kIGnet-2NYt2Kl6lqdEyjMp2_yFFbF-7w_m57FlvcBqeXRgg |
| linkToPdf | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1LS8NAEF60iujBt1ife_CkLM1jm6TH2hoUay20ld5Cd7OrhTYtTSrk37uTlxZUEC85hEkIM7OZb3ZmvkXoitoqaMKuja35DqGG8MlQSp1Iyp2hJi31f0wo81t2u-0MBrVOds5pmHe75yXJdKYBWJqCqDLzZaUYfKPgjCoNpgQ41Ui8itYo9NFDut59-dxkcaCuCBBYua1GVHpj5ZXN796yHJuWC6NJvHF3_v2lu2g7g5q4nvrGHloRwT7a-kJAeID6ADlxT0xmY4U5cTcOOJDlThchLhhosQv9Wzgd4se3Kur5uJE2uOP6-HU6H0VvE6ywL252e_Ve4_npEPXdu17jnmQHLRBuaGZMHGYOVR5iSdNI-M1sxqRlKGNxh2s2t32wm7pIpgtd3apyte6lwRitCptTZh6hUjANxDHCVBi8ZvKqIyinUudMATzdtzTouQIwVUZarmKPZyzkcBjG2Cv4kxONeUpjHmjMi8vounhkllJw_CZ8k9vEy1Zj-LP0yZ-kL9FGp-l6rYf24ynaNBKbQgvPGSpF84U4R-v8PRqF84vECT8Ae4faZg |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Unit+Template+Synchronous+Reference+Frame+Theory+Based+Control+Algorithm+for+DSTATCOM&rft.jtitle=Journal+of+the+Institution+of+Engineers+%28India%29.+Series+B%2C+Electrical+Engineering%2C+Electronics+and+telecommunication+engineering%2C+Computer+engineering&rft.au=Bangarraju%2C+J.&rft.au=Rajagopal%2C+V.&rft.au=Jayalaxmi%2C+A.&rft.date=2014-04-01&rft.issn=2250-2106&rft.eissn=2250-2114&rft.volume=95&rft.issue=2&rft.spage=135&rft.epage=141&rft_id=info:doi/10.1007%2Fs40031-014-0087-y&rft.externalDBID=n%2Fa&rft.externalDocID=10_1007_s40031_014_0087_y |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2250-2106&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2250-2106&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2250-2106&client=summon |