Could saline instillation displace bacteria from the endotracheal tube biofilm to lower airways during suctioning procedure?
The bacteria observed were: five Gram-positive (Staphylococcus aureus in three, Streptococcus pneumoniae in one and Staphylococcus haemolytics in one) and three Gram-negative (Acinetobacter baumani, Klebsiella pneumoniae, Enterobacter cloacae). Conclusion The use of saline during an endotracheal suc...
Uloženo v:
| Vydáno v: | Critical care (London, England) Ročník 19; číslo Suppl 2; s. P43 |
|---|---|
| Hlavní autoři: | , , , , , , , |
| Médium: | Journal Article |
| Jazyk: | angličtina |
| Vydáno: |
London
BioMed Central
28.09.2015
Springer Nature B.V |
| Témata: | |
| ISSN: | 1364-8535, 1364-8535, 1366-609X, 1466-609X |
| On-line přístup: | Získat plný text |
| Tagy: |
Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
|
| Shrnutí: | The bacteria observed were: five Gram-positive (Staphylococcus aureus in three, Streptococcus pneumoniae in one and Staphylococcus haemolytics in one) and three Gram-negative (Acinetobacter baumani, Klebsiella pneumoniae, Enterobacter cloacae). Conclusion The use of saline during an endotracheal suctioning procedure can dislocate pathogenic bacteria from the endotracheal tube biofilm to the lower airways, and could increase the risk of VAP. |
|---|---|
| Bibliografie: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 |
| ISSN: | 1364-8535 1364-8535 1366-609X 1466-609X |
| DOI: | 10.1186/cc14689 |