A Novel Dynamic Compression Angle‐Stable Interlocking Intramedullary Nail: Description, Validation, and Model Evaluation.
Uloženo v:
| Název: | A Novel Dynamic Compression Angle‐Stable Interlocking Intramedullary Nail: Description, Validation, and Model Evaluation. |
|---|---|
| Autoři: | Dias, Luís Gustavo Gosuen Gonçalves1 (AUTHOR), Rocha, Thiago André Salvitti Sá2 (AUTHOR), Malta, Caio Afonso Santos1 (AUTHOR), Minto, Bruno Watanabe1 (AUTHOR), Carrera, Alefe Luiz Caliani1 (AUTHOR) alefe.carrera@unesp.br, Elhaig, Mahmoud (AUTHOR) |
| Zdroj: | Veterinary Medicine International. 4/10/2025, Vol. 2025, p1-14. 14p. |
| Druh dokumentu: | Article |
| Témata: | Intramedullary fracture fixation, Intramedullary rods, Statistical significance, Compression fractures, Finite element method |
| Author-Supplied Keywords: | biological osteosynthesis experimental implants implants engineer intramedullary fracture fixation long bone fractures |
| Abstrakt: | The stabilization of long‐bone fractures using intramedullary nails offers significant biological advantages for bone healing. Nevertheless, the mechanical stability of the implant–bone interface remains suboptimal due to the absence of models capable of generating interfragmentary compression at the fracture site. To address these limitations, this study aims to describe and evaluate a novel dynamic compression angle‐stable interlocking intramedullary nail (DCASIN), designed for use in conjunction with a compression device (CD). Its performance was compared with conventional and angle‐stable interlocking intramedullary nails. Implantation was demonstrated using a tube‐based bone model with transverse fractures. Compression was achieved in the proximal aspect of the DCASIN through an oblong hole that allowed the insertion of a Steinmann pin, which was then subjected to the thrust of the CD's primary screw (PS). To evaluate dynamic compression, a load cell connected to the Arduino/Genuíno Uno software was utilized. Three groups of interlocking nails were assessed: G1 (conventional), G2 (angle‐stable), and G3 (DCASIN), with measurements taken at four time points (M1: prelocking, M2: after the first screw or PS for the DCASIN, M3: after the second implant, and M4: one‐minute post‐M3). No statistically significant differences in compression forces were observed for G1 and G2 across the measured time points. In contrast, G3 exhibited significantly higher compression at M2 than at M3 and M4, and its compression forces at M2, M3, and M4 were significantly greater than those in G1 and G2. Finite element analysis revealed no significant deformation in G3 during compression. In conclusion, the DCASIN combined with the CD achieved and sustained superior compression forces compared to conventional and angle‐stable nails, thereby offering a promising alternative for the internal fixation of long bones. [ABSTRACT FROM AUTHOR] |
| Copyright of Veterinary Medicine International is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Author Affiliations: | 1Department of Veterinary Clinics and Surgery,, School of Agricultural and Veterinarian Sciences of the São Paulo State University (FCAV UNESP),, Jaboticabal, State of São Paulo, Brazil 2Department of Veterinary Medicine,, Federal University of Jatai (UFJ),, Jataí, State of Goiás, Brazil |
| Full Text Word Count: | 7689 |
| ISSN: | 2090-8113 |
| DOI: | 10.1155/vmi/7875699 |
| Přístupové číslo: | 184403729 |
| Databáze: | Veterinary Source |
|
Nepřihlášeným uživatelům se plný text nezobrazuje
Pro úplný přístup je nutné se přihlásit.
|
|
| Abstrakt: | The stabilization of long‐bone fractures using intramedullary nails offers significant biological advantages for bone healing. Nevertheless, the mechanical stability of the implant–bone interface remains suboptimal due to the absence of models capable of generating interfragmentary compression at the fracture site. To address these limitations, this study aims to describe and evaluate a novel dynamic compression angle‐stable interlocking intramedullary nail (DCASIN), designed for use in conjunction with a compression device (CD). Its performance was compared with conventional and angle‐stable interlocking intramedullary nails. Implantation was demonstrated using a tube‐based bone model with transverse fractures. Compression was achieved in the proximal aspect of the DCASIN through an oblong hole that allowed the insertion of a Steinmann pin, which was then subjected to the thrust of the CD's primary screw (PS). To evaluate dynamic compression, a load cell connected to the Arduino/Genuíno Uno software was utilized. Three groups of interlocking nails were assessed: G1 (conventional), G2 (angle‐stable), and G3 (DCASIN), with measurements taken at four time points (M1: prelocking, M2: after the first screw or PS for the DCASIN, M3: after the second implant, and M4: one‐minute post‐M3). No statistically significant differences in compression forces were observed for G1 and G2 across the measured time points. In contrast, G3 exhibited significantly higher compression at M2 than at M3 and M4, and its compression forces at M2, M3, and M4 were significantly greater than those in G1 and G2. Finite element analysis revealed no significant deformation in G3 during compression. In conclusion, the DCASIN combined with the CD achieved and sustained superior compression forces compared to conventional and angle‐stable nails, thereby offering a promising alternative for the internal fixation of long bones. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 20908113 |
| DOI: | 10.1155/vmi/7875699 |