PROPOSAL OF INDEX FOR EVALUATING EFFICIENCY OF SEISMIC RETROFITTING APPLIED TO EXISTING RC BUILDINGS CONSIDERING FUTURE EARTHQUAKES, CONSTRUCTION COSTS AND ENVIRONMENTAL LOAD
Uloženo v:
| Název: | PROPOSAL OF INDEX FOR EVALUATING EFFICIENCY OF SEISMIC RETROFITTING APPLIED TO EXISTING RC BUILDINGS CONSIDERING FUTURE EARTHQUAKES, CONSTRUCTION COSTS AND ENVIRONMENTAL LOAD |
|---|---|
| Autoři: | Yoshida, Himari, Miura, Kota, Suzuki, Yohei, Akiya, Riho, Shegay, Alex, Monical, Jonathan, Suzuki, Yusuke, Goto, Yutaka, 1984, Maeda, Masaki, Seki, Matsutaro |
| Zdroj: | AIJ Journal of Technology and Design. 31(79):1319-1324 |
| Témata: | Cost, Environmental load, Seismic performance, Reinforcement, Repair, RC buildings |
| Popis: | A seismic reinforcement efficiency evaluation index is proposed to select the optimal seismic reinforcement plan considering seismic performance, construction costs, and environmental impact. Focusing on seismic reinforcement of existing RC buildings, construction costs and environmental impacts are normalized to those related to reconstruction. Three types of common strengthening techniques were studied: RC shear walls, steel braces, and CLT walls. The evaluation results showed that using RC shear walls was the most cost-efficient, while CLT walls had the smallest environmental impact, suggesting that the most efficient retrofitting plan depends on the weighting assigned to costs and environmental impact. |
| Popis souboru: | electronic |
| Přístupová URL adresa: | https://research.chalmers.se/publication/548834 https://research.chalmers.se/publication/548834/file/548834_Fulltext.pdf |
| Databáze: | SwePub |
| Abstrakt: | A seismic reinforcement efficiency evaluation index is proposed to select the optimal seismic reinforcement plan considering seismic performance, construction costs, and environmental impact. Focusing on seismic reinforcement of existing RC buildings, construction costs and environmental impacts are normalized to those related to reconstruction. Three types of common strengthening techniques were studied: RC shear walls, steel braces, and CLT walls. The evaluation results showed that using RC shear walls was the most cost-efficient, while CLT walls had the smallest environmental impact, suggesting that the most efficient retrofitting plan depends on the weighting assigned to costs and environmental impact. |
|---|---|
| ISSN: | 13419463 18818188 |
| DOI: | 10.3130/aijt.31.1319 |