2D-ERT data measured in June 2023 and June 2024 in the Lower Havel Inner Delta near Lake Gülpe, Brandenburg (Germany)

Gespeichert in:
Bibliographische Detailangaben
Titel: 2D-ERT data measured in June 2023 and June 2024 in the Lower Havel Inner Delta near Lake Gülpe, Brandenburg (Germany)
Autoren: Pohle, Marco, Birnstengel, Susann, Werban, Ulrike
Verlagsinformationen: PANGAEA
Publikationsjahr: 2025
Bestand: PANGAEA - Data Publisher for Earth & Environmental Science (AWI Bremerhaven / MARUM Bremen)
Schlagwörter: 2023_Havel_Transect1, 2023_Havel_Transect2, 2024_Havel_Transect3, 2024_Havel_Transect4, Binary Object, Brandenburg, Comment, Electrical Resistivity Tomography, ERT, ERT01, ERT02, ERT03, ERT04, File type, floodplain, Lake Gülpe, Near surface geophysics, RESECS multi-electrode, Transect
Geographisches Schlagwort: MEDIAN LATITUDE: 52.732178 * MEDIAN LONGITUDE: 12.214666 * SOUTH-BOUND LATITUDE: 52.727785 * WEST-BOUND LONGITUDE: 12.210985 * NORTH-BOUND LATITUDE: 52.736115 * EAST-BOUND LONGITUDE: 12.218603 * DATE/TIME START: 2023-06-13T11:47:59 * DATE/TIME END: 2024-06-04T13:36:06
Beschreibung: The Electrical Resistivity Tomography (ERT) data were acquired by using a PC controlled DC resistivity meter system (RESECS, Geoserve, Kiel, Germany). In total, we measured four ERT transects. Two transects in June 2023, where transect 1 had a total length of 259 m with an electrode spacing of 0.5 m and transect 2 had a total length of 223 m with an electrode spacing of 1 m. The measurements in 2023 were carried out under extreme dry conditions. Two further transects were measured in June 2024 with an electrode spacing of 1m, transect 3 with a total length of 207 m and transect 4 with a total length of 239 m. We applied wenner alpha and dipol-dipol configuration. The coordinates and the height of the electrodes were measured with a D-GPS (2023: TOPCON HiPer II / 2024: Leica GPS1200).
Publikationsart: dataset
Dateibeschreibung: text/tab-separated-values, 16 data points
Sprache: English
Relation: https://doi.org/10.1594/PANGAEA.983208; Köhler, Anne; Pohle, Marco; Bauckholt, Matteo; Birnstengel, Susann; Kaniecki, Marie; Schneider, Birgit; Werban, Ulrike; Zielhofer, Christoph (2025): Near-surface geophysical and sedimentological analyses for the Lower Havel Inner Delta – a dataset of the floodplain lithostratigraphy. Data in Brief, 112372, https://doi.org/10.1016/j.dib.2025.112372; Pohle, Marco (2025): ERT Measurement setup and data structure from transect 1 - Havel. https://download.pangaea.de/reference/134004/attachments/Explanation_ERT-Data_Havel_transect1.pdf; Pohle, Marco (2025): ERT Measurement setup and data structure from transect 2 - Havel. https://download.pangaea.de/reference/134005/attachments/Explanation_ERT-Data_Havel_transect2.pdf; Pohle, Marco (2025): ERT Measurement setup and data structure from transect 3 - Havel. https://download.pangaea.de/reference/134006/attachments/Explanation_ERT-Data_Havel_transect3_v2.pdf; Pohle, Marco (2025): ERT Measurement setup and data structure from transect 4 - Havel. https://download.pangaea.de/reference/134007/attachments/Explanation_ERT-Data_Havel_transect4.pdf; https://doi.pangaea.de/10.1594/PANGAEA.983478; https://doi.org/10.1594/PANGAEA.983478
DOI: 10.1594/PANGAEA.983478
Verfügbarkeit: https://doi.pangaea.de/10.1594/PANGAEA.983478
https://doi.org/10.1594/PANGAEA.983478
Rights: CC-BY-4.0: Creative Commons Attribution 4.0 International ; Access constraints: unrestricted ; info:eu-repo/semantics/openAccess
Dokumentencode: edsbas.EC051234
Datenbank: BASE
Beschreibung
Abstract:The Electrical Resistivity Tomography (ERT) data were acquired by using a PC controlled DC resistivity meter system (RESECS, Geoserve, Kiel, Germany). In total, we measured four ERT transects. Two transects in June 2023, where transect 1 had a total length of 259 m with an electrode spacing of 0.5 m and transect 2 had a total length of 223 m with an electrode spacing of 1 m. The measurements in 2023 were carried out under extreme dry conditions. Two further transects were measured in June 2024 with an electrode spacing of 1m, transect 3 with a total length of 207 m and transect 4 with a total length of 239 m. We applied wenner alpha and dipol-dipol configuration. The coordinates and the height of the electrodes were measured with a D-GPS (2023: TOPCON HiPer II / 2024: Leica GPS1200).