Interplay Among Muscle Oxygen Saturation, Activation, and Power on a Swim-Bench
Uloženo v:
| Název: | Interplay Among Muscle Oxygen Saturation, Activation, and Power on a Swim-Bench |
|---|---|
| Autoři: | Vittorio Coloretti, Claudio Quagliarotti, Giorgio Gatta, Maria Francesca Piacentini, Matteo Cortesi, Silvia Fantozzi |
| Přispěvatelé: | Physiotherapy, Human Physiology and Anatomy, Human Physiology and Sports Physiotherapy Research Group |
| Zdroj: | Sensors (Basel) Sensors, Vol 25, Iss 13, p 4148 (2025) |
| Informace o vydavateli: | MDPI AG, 2025. |
| Rok vydání: | 2025 |
| Témata: | Male, Adult, Chemical technology, peripheral fatigue, Oxygen Saturation/physiology, oximeter, TP1-1185, Oximetry/methods, Oxygen/metabolism, Article, Muscle, Skeletal/physiology, incremental workload, sEMG, Swimming/physiology, Humans, young adult, concurrent validity, agreement, Electromyography/methods |
| Popis: | Muscle activity during exercise is typically assessed using oximeters, to evaluate local oxygen saturation (SmO2), or surface electromyography (sEMG), to analyze electrical activation. Despite the importance of combining these analyses, no study has evaluated both of them during specific swimming exercises in combination with mechanical power output. This study aimed to assess muscle activity during an incremental test on a swim-bench utilizing oximeters and sEMG. Nine male swimmers performed a five-steps test: PRE (3 min at rest), STEP 1, 2, and 3 (swimming at a frequency of 25, 30, and 40 cycle/min for a duration of 2, 2, and 1 min, respectively), and POST (5 min at rest). Each swimmer wore two oximeters and sEMG, one for each triceps brachii. Stroke frequency and arm mechanical power (from ~13 to ~52 watts) estimated by the swim-bench were different among all steps, while no differences between arms were found. SmO2 (from ~70% to ~60%) and sEMG signals (from ~20 to ~65% in signal amplitude) showed a significant increase among all steps. In both arms, a large/very large correlation was found between mechanical power and SmO2 (r < −0.634), mechanical power and sEMG onset/amplitude (r > 0.581), and SmO2 and sEMG amplitude (r > 0.508). No correlations were found between the slope of the sEMG spectral indexes and the slope of SmO2; only sEMG detected electrical manifestation of muscle fatigue through the steps (p < 0.05). Increased muscle activity, assessed by both oximeters and sEMG, was found at mechanical power increases, revealing both devices can detect effort variation during exercise. However, only sEMG seems to detect peripheral manifestations of fatigue in dynamic conditions. |
| Druh dokumentu: | Article Other literature type |
| Jazyk: | English |
| ISSN: | 1424-8220 |
| DOI: | 10.3390/s25134148 |
| Přístupová URL adresa: | https://doaj.org/article/1fd164dcf33349128571858c7c3026d8 https://biblio.vub.ac.be/vubir/interplay-among-muscle-oxygen-saturation-activation-and-power-on-a-swimbench(2908eb2e-34ba-452b-b330-b458e8b56c92).html |
| Rights: | CC BY |
| Přístupové číslo: | edsair.doi.dedup.....ded808412ac8a6b05ddac70b75ee843b |
| Databáze: | OpenAIRE |
| Abstrakt: | Muscle activity during exercise is typically assessed using oximeters, to evaluate local oxygen saturation (SmO2), or surface electromyography (sEMG), to analyze electrical activation. Despite the importance of combining these analyses, no study has evaluated both of them during specific swimming exercises in combination with mechanical power output. This study aimed to assess muscle activity during an incremental test on a swim-bench utilizing oximeters and sEMG. Nine male swimmers performed a five-steps test: PRE (3 min at rest), STEP 1, 2, and 3 (swimming at a frequency of 25, 30, and 40 cycle/min for a duration of 2, 2, and 1 min, respectively), and POST (5 min at rest). Each swimmer wore two oximeters and sEMG, one for each triceps brachii. Stroke frequency and arm mechanical power (from ~13 to ~52 watts) estimated by the swim-bench were different among all steps, while no differences between arms were found. SmO2 (from ~70% to ~60%) and sEMG signals (from ~20 to ~65% in signal amplitude) showed a significant increase among all steps. In both arms, a large/very large correlation was found between mechanical power and SmO2 (r < −0.634), mechanical power and sEMG onset/amplitude (r > 0.581), and SmO2 and sEMG amplitude (r > 0.508). No correlations were found between the slope of the sEMG spectral indexes and the slope of SmO2; only sEMG detected electrical manifestation of muscle fatigue through the steps (p < 0.05). Increased muscle activity, assessed by both oximeters and sEMG, was found at mechanical power increases, revealing both devices can detect effort variation during exercise. However, only sEMG seems to detect peripheral manifestations of fatigue in dynamic conditions. |
|---|---|
| ISSN: | 14248220 |
| DOI: | 10.3390/s25134148 |
Full Text Finder
Nájsť tento článok vo Web of Science