Sensitive Bioassay with an Ultralarge Dynamic Range via Microlaser Ensemble Quenching

Gespeichert in:
Bibliographische Detailangaben
Titel: Sensitive Bioassay with an Ultralarge Dynamic Range via Microlaser Ensemble Quenching
Autoren: Weishu Wu, Yuhang Cao, Xiaotian Tan, Xudong Fan
Quelle: ACS Sensors. 10:6436-6445
Publication Status: Preprint
Verlagsinformationen: American Chemical Society (ACS), 2025.
Publikationsjahr: 2025
Schlagwörter: FOS: Physical sciences, Physics - Applied Physics, Applied Physics (physics.app-ph), Physics - Optics, Optics (physics.optics)
Beschreibung: We present a bioassay platform that leverages the lasing threshold distribution in a microlaser ensemble (ME), consisting of hundreds of individual microlasers, to measure analyte concentrations in solution. An ME is formed by placing dye-doped microbeads in a micro Fabry-Perot cavity. Microbeads are surface modified with biorecognition molecules to capture analytes, while the quenchers resulting from the presence of the analytes on the microbeads' surfaces increase the lasing thresholds of microlasers. Since the number of analytes varies from one microbead (or microlaser) to another due to the randomness in binding processes, a distribution of the analytes (and hence the quenchers) in the ME is created, which in turn leads to a lasing threshold distribution in the ME. Experimentally, multiple pumping energy densities are used to probe the lasing threshold distribution. A theoretical model is developed to map the lasing threshold distribution to analyte distribution in the ME, and then to recover the analyte concentration in solution. Using streptavidin and interleukin-6 as a model system, our platform achieves a detection limit of 0.1 pg/mL and a dynamic range exceeding five orders of magnitude, showing that the ME quenching method can provide a high sensitivity with a superior dynamic range.
6 figures, 43 pages, submitted
Publikationsart: Article
Sprache: English
ISSN: 2379-3694
DOI: 10.1021/acssensors.5c00251
DOI: 10.48550/arxiv.2501.15299
Zugangs-URL: http://arxiv.org/abs/2501.15299
Rights: STM Policy #29
CC BY
Dokumentencode: edsair.doi.dedup.....a2833e6e773ca4fc0720e01dcb79b06b
Datenbank: OpenAIRE
Beschreibung
Abstract:We present a bioassay platform that leverages the lasing threshold distribution in a microlaser ensemble (ME), consisting of hundreds of individual microlasers, to measure analyte concentrations in solution. An ME is formed by placing dye-doped microbeads in a micro Fabry-Perot cavity. Microbeads are surface modified with biorecognition molecules to capture analytes, while the quenchers resulting from the presence of the analytes on the microbeads' surfaces increase the lasing thresholds of microlasers. Since the number of analytes varies from one microbead (or microlaser) to another due to the randomness in binding processes, a distribution of the analytes (and hence the quenchers) in the ME is created, which in turn leads to a lasing threshold distribution in the ME. Experimentally, multiple pumping energy densities are used to probe the lasing threshold distribution. A theoretical model is developed to map the lasing threshold distribution to analyte distribution in the ME, and then to recover the analyte concentration in solution. Using streptavidin and interleukin-6 as a model system, our platform achieves a detection limit of 0.1 pg/mL and a dynamic range exceeding five orders of magnitude, showing that the ME quenching method can provide a high sensitivity with a superior dynamic range.<br />6 figures, 43 pages, submitted
ISSN:23793694
DOI:10.1021/acssensors.5c00251