A Water Absorption Chamber Design for Cable Capacitance Measurement Tests

Uložené v:
Podrobná bibliografia
Názov: A Water Absorption Chamber Design for Cable Capacitance Measurement Tests
Autori: Ercan Ulutay, Metin Yurtsever, Avşin Öztaş, Uğur Akyol, Reşat Mutlu
Zdroj: Volume: 7, Issue: 2150-158
European Journal of Engineering and Applied Sciences
Informácie o vydavateľovi: Namik Kemal University, 2024.
Rok vydania: 2024
Predmety: Güç Kabloları, Su Emme Testi, Kablo Testleri, Termal Tasarım, Isıtıcı Tasarımı, Süreç Kontrolü ve Simülasyonu, Power Cables, Water Absorption Test, Cable Tests, Thermal Design, Elektrik Devreleri ve Sistemleri, Process Control and Simulation, Electrical Circuits and Systems
Popis: XLPO cables used in ships should be tested for water absorption. Test standards require the cables be submerged in a water absorption chamber and kept at 75 0C for 14 days. Once every 7 days, the cables within the chamber are tested by applying high voltage, and their capacitance, dissipation factor, stability factor, and relative Permittivity are measured. In this study, a water absorption chamber used in the experiments is designed using fiberglass material and controlled with an ENDA ET 4420 temperature controller. It is experimentally shown that the water absorption chamber performs well.
Druh dokumentu: Article
Popis súboru: application/pdf
ISSN: 2651-3412
DOI: 10.55581/ejeas.1598086
Prístupová URL adresa: https://dergipark.org.tr/tr/pub/ejeas/issue/88088/1598086
Prístupové číslo: edsair.doi.dedup.....99b5085736d03d9761154980f2b1337b
Databáza: OpenAIRE
Popis
Abstrakt:XLPO cables used in ships should be tested for water absorption. Test standards require the cables be submerged in a water absorption chamber and kept at 75 0C for 14 days. Once every 7 days, the cables within the chamber are tested by applying high voltage, and their capacitance, dissipation factor, stability factor, and relative Permittivity are measured. In this study, a water absorption chamber used in the experiments is designed using fiberglass material and controlled with an ENDA ET 4420 temperature controller. It is experimentally shown that the water absorption chamber performs well.
ISSN:26513412