A Water Absorption Chamber Design for Cable Capacitance Measurement Tests
Uložené v:
| Názov: | A Water Absorption Chamber Design for Cable Capacitance Measurement Tests |
|---|---|
| Autori: | Ercan Ulutay, Metin Yurtsever, Avşin Öztaş, Uğur Akyol, Reşat Mutlu |
| Zdroj: | Volume: 7, Issue: 2150-158 European Journal of Engineering and Applied Sciences |
| Informácie o vydavateľovi: | Namik Kemal University, 2024. |
| Rok vydania: | 2024 |
| Predmety: | Güç Kabloları, Su Emme Testi, Kablo Testleri, Termal Tasarım, Isıtıcı Tasarımı, Süreç Kontrolü ve Simülasyonu, Power Cables, Water Absorption Test, Cable Tests, Thermal Design, Elektrik Devreleri ve Sistemleri, Process Control and Simulation, Electrical Circuits and Systems |
| Popis: | XLPO cables used in ships should be tested for water absorption. Test standards require the cables be submerged in a water absorption chamber and kept at 75 0C for 14 days. Once every 7 days, the cables within the chamber are tested by applying high voltage, and their capacitance, dissipation factor, stability factor, and relative Permittivity are measured. In this study, a water absorption chamber used in the experiments is designed using fiberglass material and controlled with an ENDA ET 4420 temperature controller. It is experimentally shown that the water absorption chamber performs well. |
| Druh dokumentu: | Article |
| Popis súboru: | application/pdf |
| ISSN: | 2651-3412 |
| DOI: | 10.55581/ejeas.1598086 |
| Prístupová URL adresa: | https://dergipark.org.tr/tr/pub/ejeas/issue/88088/1598086 |
| Prístupové číslo: | edsair.doi.dedup.....99b5085736d03d9761154980f2b1337b |
| Databáza: | OpenAIRE |
| Abstrakt: | XLPO cables used in ships should be tested for water absorption. Test standards require the cables be submerged in a water absorption chamber and kept at 75 0C for 14 days. Once every 7 days, the cables within the chamber are tested by applying high voltage, and their capacitance, dissipation factor, stability factor, and relative Permittivity are measured. In this study, a water absorption chamber used in the experiments is designed using fiberglass material and controlled with an ENDA ET 4420 temperature controller. It is experimentally shown that the water absorption chamber performs well. |
|---|---|