Efficient Phantom Source Widening
Uloženo v:
| Název: | Efficient Phantom Source Widening |
|---|---|
| Autoři: | Franz Zotter, Matthias Frank |
| Zdroj: | Archives of Acoustics, Vol 38, Iss 1 (2013) |
| Informace o vydavateli: | Polish Academy of Sciences Chancellery, 2013. |
| Rok vydání: | 2013 |
| Témata: | source widening, decorrelation, 03 medical and health sciences, phantom source, 0103 physical sciences, Acoustics. Sound, QC221-246, IACC, 0305 other medical science, 01 natural sciences |
| Popis: | We present a highly efficient filter structure to create power-complementary filter pairs for phantom source widening. It either introduces frequency-dependent phase or amplitude differences in a pair of loudspeaker signals. We evaluate how the perceptual effect is influenced by off-center listening positions in a standard ±30° loudspeaker setup. The evaluation of the phantom source widening effect is based on measurements of the inter-aural cross-correlation coefficient (IACC), which is justified by its pronounced correlation to the perceived phantom source width in prior listening test results. |
| Druh dokumentu: | Article |
| ISSN: | 0137-5075 |
| DOI: | 10.2478/aoa-2013-0004 |
| Přístupová URL adresa: | https://doaj.org/article/42c8dcf3dfa24482aad6e25154b8b3ae https://acoustics.ippt.gov.pl/index.php/aa/article/view/4 https://acoustics.ippt.pan.pl/index.php/aa/article/download/4/pdf_1 http://cejsh.icm.edu.pl/cejsh/element/bwmeta1.element.oai-journals-pan-pl-101499 https://acoustics.ippt.pan.pl/index.php/aa/article/view/4 http://yadda.icm.edu.pl/yadda/element/bwmeta1.element.baztech-31d5f2bf-1ea8-40a6-bea9-20c9c76ce23a https://acoustics.ippt.gov.pl/index.php/aa/article/download/4/pdf_1 |
| Přístupové číslo: | edsair.doi.dedup.....71bffccf68b32386c59e604002024809 |
| Databáze: | OpenAIRE |
| Abstrakt: | We present a highly efficient filter structure to create power-complementary filter pairs for phantom source widening. It either introduces frequency-dependent phase or amplitude differences in a pair of loudspeaker signals. We evaluate how the perceptual effect is influenced by off-center listening positions in a standard ±30° loudspeaker setup. The evaluation of the phantom source widening effect is based on measurements of the inter-aural cross-correlation coefficient (IACC), which is justified by its pronounced correlation to the perceived phantom source width in prior listening test results. |
|---|---|
| ISSN: | 01375075 |
| DOI: | 10.2478/aoa-2013-0004 |
Full Text Finder
Nájsť tento článok vo Web of Science