Studies on Silicone Rubber Insulators used for High Voltage Transmission

Uloženo v:
Podrobná bibliografie
Název: Studies on Silicone Rubber Insulators used for High Voltage Transmission
Autoři: Chakraborty, Rahul
Přispěvatelé: Subha Reddy, B
Informace o vydavateli: 2017.
Rok vydání: 2017
Témata: Silicone Rubber Insulator, SIR Insulators, Polymeric Insulators, 13. Climate action, Silicon Rubber Insulators, HTV SIR Insulators, Silicone Rubber, High Voltage Transmission, High Temperature Vulcanized Silicone Rubber, Wettability Class (WC) Measurement, Electrical Engineering
Popis: Recently high temperature vulcanized (HTV) silicone rubber (SIR) / polymeric/composite insulators are gaining wider acceptance as overhead transmission line insulators for extra high voltage (EHV) and ultra-high voltage (UHV) systems due to some promising features like hydrophobicity recovery, light weight, ease of handling and installation, better pollution ashover performance, admirable resistance against vandalism etc. Since polymeric insula-tors are of recent origin, their long-term eld performance is yet to be understood. Owing to their organic nature, and exposure to environmental stresses like pollution, temperature, UV radiation, humidity, fog, rain etc., the insulator performance degrades over a period. The sheds/petticoats of the insulators become wettable leading to frequent ashover in humid and contaminated environment. Hence, long term reliability of the composite insulators is of foremost concern to the power utilities. The available literature on the long term eld performance of these insulators for di erent climatic conditions and under multiple environ-mental stresses for both the HTV SIR and Liquid Silicone Rubber (LSR) is scant. Also there is no reference standard for evaluation of these insulators for pollution/contamination test methods in the laboratory. However currently, CIGRE Work Group is working towards the standardization of the test methods for arti cial pollution tests for polymeric insulators. The thesis addresses some of the issues in detail. In the first part of the thesis, a new and simple pre-treatment methodology to achieve uniform contamination layer on inherently hydrophobic HTV SIR Insulator samples is presented for laboratory pollution performance evaluation. The surface water level di usion in the dipping period is found to make the insulator surface temporarily hydrophilic. Then the uniform contamination layer is applied by dipping the sample immediately in the pollution slurry. Exhaustive experiments were conducted on full scale SIR insulators as well as SIR slabs to ...
Druh dokumentu: Thesis
Popis souboru: application/pdf
DOI: 10.13140/rg.2.2.34578.76484
Přístupové číslo: edsair.doi.dedup.....09ab7abaecdabeaa62ee9b64083a5ef6
Databáze: OpenAIRE
Popis
Abstrakt:Recently high temperature vulcanized (HTV) silicone rubber (SIR) / polymeric/composite insulators are gaining wider acceptance as overhead transmission line insulators for extra high voltage (EHV) and ultra-high voltage (UHV) systems due to some promising features like hydrophobicity recovery, light weight, ease of handling and installation, better pollution ashover performance, admirable resistance against vandalism etc. Since polymeric insula-tors are of recent origin, their long-term eld performance is yet to be understood. Owing to their organic nature, and exposure to environmental stresses like pollution, temperature, UV radiation, humidity, fog, rain etc., the insulator performance degrades over a period. The sheds/petticoats of the insulators become wettable leading to frequent ashover in humid and contaminated environment. Hence, long term reliability of the composite insulators is of foremost concern to the power utilities. The available literature on the long term eld performance of these insulators for di erent climatic conditions and under multiple environ-mental stresses for both the HTV SIR and Liquid Silicone Rubber (LSR) is scant. Also there is no reference standard for evaluation of these insulators for pollution/contamination test methods in the laboratory. However currently, CIGRE Work Group is working towards the standardization of the test methods for arti cial pollution tests for polymeric insulators. The thesis addresses some of the issues in detail. In the first part of the thesis, a new and simple pre-treatment methodology to achieve uniform contamination layer on inherently hydrophobic HTV SIR Insulator samples is presented for laboratory pollution performance evaluation. The surface water level di usion in the dipping period is found to make the insulator surface temporarily hydrophilic. Then the uniform contamination layer is applied by dipping the sample immediately in the pollution slurry. Exhaustive experiments were conducted on full scale SIR insulators as well as SIR slabs to ...
DOI:10.13140/rg.2.2.34578.76484