Podrobná bibliografie
| Název: |
Quantification of Flurbiprofen in Eye Drops by Stability Indicating Ultraviolet Spectrophotometric Method. |
| Autoři: |
PONNAM, C., CHALLA, G. N., YARRAGUNTLA, S. R. |
| Zdroj: |
Indian Journal of Pharmaceutical Sciences; May/Jun2023, Vol. 85 Issue 3, p753-760, 8p |
| Témata: |
EYE drops, FLURBIPROFEN, DETECTION limit, STANDARD deviations |
| Abstrakt: |
An efficient, rapid, sensitive, validated stability-indicating ultraviolet spectrophotometric method was developed for flurbiprofen in eye drops. Methanol was employed as the solvent in this proposed process, and detection was carried out at a wavelength of 248 nm. The validation parameters linearity, limit of detection and limit of quantitation, accuracy, precision and specificity were all the subject of experiments according to International Council on Harmonisation guidelines. The stability of flurbiprofen was examined under acidic, alkaline, thermal, and photolytic conditions. The kinetics in the concentration range of 2-10 ug/ml were defined as linear with a correlation value of 0.992. The percentage of relative standard deviation for both intra-day and inter-day accuracy was under less than 2 % and 99.6 %-100.4 % of the drug was retrieved from the study. The system was able to identify variations related to stress conditions although the stress condition of degradation products hadn't been determined. The proposed approach can be employed as a stability indicating method for flurbiprofen screening in conventional pharmaceutical analysis of eye drops with a significant level of linearity, accuracy and precision. The method was found to be both affordable and convenient. This method can therefore be used to study flurbiprofen stress degradation behaviour in small industries without access to sophisticated equipment. [ABSTRACT FROM AUTHOR] |
|
Copyright of Indian Journal of Pharmaceutical Sciences is the property of Indian Journal of Pharmaceutical Sciences and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Databáze: |
Biomedical Index |