Current controller considering harmonics compensation for grid connected converter in DPGS applications.

Saved in:
Bibliographic Details
Title: Current controller considering harmonics compensation for grid connected converter in DPGS applications.
Authors: Barote, L., Marinescu, C., Teodorescu, R.
Source: 2012 13th International Conference on Optimization of Electrical & Electronic Equipment (OPTIM); 1/ 1/2012, p899-905, 7p
Abstract: This paper deals with the design and implementation of PR current control method in the αβ stationary reference frame for the grid side converter in Distributed Power Generation Systems (DPGS) applications. The goals of this paper are to implement a control technique for the grid side inverter including a LC filter, a compensation technique for low-order harmonics and to examine the grid current harmonic content with and without harmonic compensation. A comparative study in terms of current harmonic distortion between two different values of PR proportional gain running in steady state condition is made. The analyzed structure was simulated with Simulink software, then implemented and tested in laboratory using a dSPACE setup. The parameters of the system can be set according to the used experimental setup to validate the simulation results. [ABSTRACT FROM PUBLISHER]
Copyright of 2012 13th International Conference on Optimization of Electrical & Electronic Equipment (OPTIM) is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Complementary Index
Description
Abstract:This paper deals with the design and implementation of PR current control method in the αβ stationary reference frame for the grid side converter in Distributed Power Generation Systems (DPGS) applications. The goals of this paper are to implement a control technique for the grid side inverter including a LC filter, a compensation technique for low-order harmonics and to examine the grid current harmonic content with and without harmonic compensation. A comparative study in terms of current harmonic distortion between two different values of PR proportional gain running in steady state condition is made. The analyzed structure was simulated with Simulink software, then implemented and tested in laboratory using a dSPACE setup. The parameters of the system can be set according to the used experimental setup to validate the simulation results. [ABSTRACT FROM PUBLISHER]
ISBN:9781467316507
DOI:10.1109/OPTIM.2012.6231827