Podrobná bibliografie
| Název: |
Optimal power flow of thermal-wind-solar power system using enhanced Kepler optimization algorithm: Case study of a large-scale practical power system. |
| Autoři: |
Abid, Mokhtar, Belazzoug, Messaoud, Mouassa, Souhil, Chanane, Abdallah, Jurado, Francisco |
| Zdroj: |
Wind Engineering; Oct2024, Vol. 48 Issue 5, p708-739, 32p |
| Témata: |
OPTIMIZATION algorithms, RENEWABLE energy sources, ELECTRICAL load, POWER resources, PROBABILITY density function |
| Abstrakt: |
In the current century, electrical networks have witnessed great developments and continuous increases in the demand for fossil fuels based energy, leading to an excessive rise in the total production cost (TPC), as well as the pollutant (toxic) gases emitted by thermal plants. Under this circumstances, energy supply from different resources became necessary, such as renewable energy sources (RES) as an alternative solution. This latter, however, characterized with uncertainty nature in its operation principle, especially when operator system wants to define the optimal contribution of each resource in an effort to ensure economic and enhanced reliability of grid. This paper presents an Enhanced version of Kepler optimization algorithm (EKOA) to solve the problem of stochastic optimal power flow (SOPF) in a most efficient way incorporating wind power generators and solar photovoltaic with different objective functions, the stochastic nature of wind speed and solar is modeled using Weibull and lognormal probability density functions respectively. To prove the effectiveness of the proposed EKOA, various case studies were carried out on two test systems IEEE 30-bus system and Algerian power system 114-bus, obtained results were evaluated in comparison with those obtained using the original KOA and other methods published in the literatures. Thus, shows the effectiveness and superiority of the efficient EKOA over other optimizers to solve complex problem. The incorporation of RES resulted in a significant 2.39% decrease in production cost, showcasing EKOA's efficiency with a $780/h, compared to KOA's $781/h, for IEEE 30-bus system. For the DZA 114-bus system revealed even more substantial reductions, with EKOA achieving an impressive 12.6% reduction, and KOA following closely with a 12.4% decrease in production cost. [ABSTRACT FROM AUTHOR] |
|
Copyright of Wind Engineering is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Databáze: |