Podrobná bibliografie
| Název: |
Flexible Dual-Channel Digital Auscultation Patch With Active Noise Reduction for Bowel Sound Monitoring and Application. |
| Autoři: |
Wang, Gang, Yang, Yingyun, Chen, Siyu, Fu, Ji, Wu, Dong, Yang, Aiming, Ma, Yinji, Feng, Xue |
| Zdroj: |
IEEE Journal of Biomedical & Health Informatics; Jul2022, Vol. 26 Issue 7, p2951-2962, 12p |
| Témata: |
NOISE control, TIME-frequency analysis, AUSCULTATION, ADAPTIVE filters, SOUNDS, STETHOSCOPES, DIAGNOSIS, ORTHOPEDIC braces |
| Abstrakt: |
Bowel sounds (BSs) have important clinical value in the auxiliary diagnosis of digestive diseases, but due to the inconvenience of long-term monitoring and too much interference from environmental noise, they have not been well studied. Most of the current electronic stethoscopes are hard and bulky without the function of noise reduction, and their application for long-term wearable monitoring of BS in noisy clinical environments is very limited. In this paper, a flexible dual-channel digital auscultation patch with active noise reduction is designed and developed, which is wireless, wearable, and conformably attached to abdominal skin to record BS more accurately. The ambient noise can be greatly reduced through active noise reduction based on the adaptive filter. At the same time, some nonstationary noises appearing intermittently (e.g., frictional noise) can also be removed from BS by the cross validation of multichannel simultaneous acquisition. Then, two kinds of typical BS signals are taken as examples, and the feature parameters of the BS in the time domain and frequency domain are extracted through the time-frequency analysis algorithm. Furthermore, based on the short-term energy ratio between the four channels of dual patches, the two-dimensional localization of BS on the abdomen mapping plane is realized. Finally, the continuous wearable monitoring of BS for patients with postoperative ileus (POI) in the noisy ward from pre-operation (POD0) to postoperative Day 7 (POD7) was carried out. The obtained change curve of the occurrence frequency of BS provides guidance for doctors to choose a reasonable feeding time for patients after surgery and accelerate their recovery. Therefore, flexible dual-channel digital auscultation patches with active noise reduction will have promising applications in the clinical auxiliary diagnosis of digestive diseases. [ABSTRACT FROM AUTHOR] |
|
Copyright of IEEE Journal of Biomedical & Health Informatics is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Databáze: |
Complementary Index |