Název: Positioning Performance of a Sub-Arc-Second Micro-Drive Rotary System.
Autoři: Yang, Manzhi, Lv, Zhenyang, Zhang, Chuanwei, Yang, Yizhi, Jing, Gang, Guo, Wei, Lu, Zhengxiong, Huang, Yumei, Wei, Kaiyang, Li, Linyue, Feng, Bin, Ge, Hongyu
Zdroj: Micromachines; Sep2021, Vol. 12 Issue 9, p1063, 1p
Témata: PIEZOELECTRIC actuators, PIEZOELECTRIC ceramics, REFERENCE values, MICROMACHINING
Abstrakt: In the macro/micro dual-drive rotary system, the micro-drive system compensates for the position error of the macro-drive system. To realize the sub-arc-second (i.e., level of 1″–0.1″) positioning of the macro/micro dual-drive rotary system, it is necessary to study the positioning performance of the sub-arc-second micro-drive rotary system. In this paper, we designed a sub-arc-second micro-drive rotary system consisting of a PZT (piezoelectric actuator) and a micro rotary mechanism, and used simulation and experimental methods to study the positioning performance of the system. First, the micro-drive rotary system was developed to provide ultra-precise rotary motion. In this system, the PZT has ultrahigh resolution at a level of 0.1 nanometers in linear motion; a micro rotating mechanism was designed according to the composite motion principle of the flexible hinge, which could transform the linear motion of piezoelectric ceramics into rotating motion accurately. Second, the drive performance was analyzed based on the drive performance experiment. Third, kinematics, simulation, and experiments were carried out to analyze the transformation performance of the system. Finally, the positioning performance equation of the system was established based on the two performance equations, and the maximum rotary displacements and positioning error of the system were calculated. The study results showed that the system can provide precision motion at the sub-arc-second and good linearity of motion. This study has a certain reference value in ultra-precision positioning and micromachining for research on rotary motion systems at the sub-arc-second level. [ABSTRACT FROM AUTHOR]
Copyright of Micromachines is the property of MDPI and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Databáze: Complementary Index
Popis
Abstrakt:In the macro/micro dual-drive rotary system, the micro-drive system compensates for the position error of the macro-drive system. To realize the sub-arc-second (i.e., level of 1″–0.1″) positioning of the macro/micro dual-drive rotary system, it is necessary to study the positioning performance of the sub-arc-second micro-drive rotary system. In this paper, we designed a sub-arc-second micro-drive rotary system consisting of a PZT (piezoelectric actuator) and a micro rotary mechanism, and used simulation and experimental methods to study the positioning performance of the system. First, the micro-drive rotary system was developed to provide ultra-precise rotary motion. In this system, the PZT has ultrahigh resolution at a level of 0.1 nanometers in linear motion; a micro rotating mechanism was designed according to the composite motion principle of the flexible hinge, which could transform the linear motion of piezoelectric ceramics into rotating motion accurately. Second, the drive performance was analyzed based on the drive performance experiment. Third, kinematics, simulation, and experiments were carried out to analyze the transformation performance of the system. Finally, the positioning performance equation of the system was established based on the two performance equations, and the maximum rotary displacements and positioning error of the system were calculated. The study results showed that the system can provide precision motion at the sub-arc-second and good linearity of motion. This study has a certain reference value in ultra-precision positioning and micromachining for research on rotary motion systems at the sub-arc-second level. [ABSTRACT FROM AUTHOR]
ISSN:2072666X