The one-minute sit-to-stand test is an alternative to the 6-minute walk test in patients with atrial fibrillation: A cross-sectional study and ROC curve analysis.
Uložené v:
| Názov: | The one-minute sit-to-stand test is an alternative to the 6-minute walk test in patients with atrial fibrillation: A cross-sectional study and ROC curve analysis. |
|---|---|
| Autori: | Bozdemir Ozel C; Eskisehir Osmangazi University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Eskisehir, Turkey. Electronic address: cbozdemirozel@gmail.com., Yakut Ozdemir H; Izmir Democracy University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Izmir, Turkey. Electronic address: fzthazalyakut@outlook.com., Dural M; Eskisehir Osmangazi University, Faculty of Medicine, Department of Cardiology, Eskisehir, Turkey; Maastricht University Medical Centre, Cardiovascular Research Institute Maastricht (CARIM), Department of Cardiology, Maastricht, Netherlands. Electronic address: muhammet_dural@hotmail.com., Al A; Eskisehir Yunus Emre State Hospital, Department of Cardiology, Eskisehir, Turkey. Electronic address: aytugal@gmail.com., Yalvac HE; Eskisehir City Hospital, Department of Cardiology, Eskisehir, Turkey. Electronic address: emre_yalvac@hotmail.com., Mert GO; Eskisehir Osmangazi University, Faculty of Medicine, Department of Cardiology, Eskisehir, Turkey. Electronic address: gozgeyun@gmail.com., Murat S; Eskisehir Osmangazi University, Faculty of Medicine, Department of Cardiology, Eskisehir, Turkey. Electronic address: selda.eraslan@hotmail.com., Cavusoglu Y; Eskisehir Osmangazi University, Faculty of Medicine, Department of Cardiology, Eskisehir, Turkey. Electronic address: yukselc@ogu.edu.tr. |
| Zdroj: | International journal of cardiology [Int J Cardiol] 2025 Jan 15; Vol. 419, pp. 132713. Date of Electronic Publication: 2024 Nov 07. |
| Spôsob vydávania: | Journal Article |
| Jazyk: | English |
| Informácie o časopise: | Publisher: Elsevier Country of Publication: Netherlands NLM ID: 8200291 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1874-1754 (Electronic) Linking ISSN: 01675273 NLM ISO Abbreviation: Int J Cardiol Subsets: MEDLINE |
| Imprint Name(s): | Publication: Amsterdam : Elsevier Original Publication: Amsterdam : Elsevier/North-Holland Biomedical Press, c1981- |
| Výrazy zo slovníka MeSH: | Atrial Fibrillation*/physiopathology , Atrial Fibrillation*/diagnosis , Walk Test*/methods , Exercise Test*/methods , Exercise Test*/standards , Exercise Tolerance*/physiology , ROC Curve*, Humans ; Male ; Female ; Cross-Sectional Studies ; Middle Aged ; Aged ; Reproducibility of Results ; Time Factors ; Standing Position |
| Abstrakt: | Competing Interests: Declaration of competing interest None. Background: The one-minute sit-to-stand test (1STST) is an easy-to-administer, space and time-saving test for determining functional exercise capacity in cardiac disease. This study aimed to investigate the 1STST -test-retest reliability and convergent validity and compare its physiological responses to the six-minute walk test (6MWT) in patients with Atrial fibrillation (AF). Methods: Forty-five patients with AF were included in this study. Functional exercise capacity was evaluated using the 1STST and 6MWT. For assessing test-retest reliability, the intraclass correlation coefficient and Bland-Altman plots were utilised. Convergent validity was determined by correlation analysis 1 STST and 6MWT, age, European Heart Rhythm Association score, ejection fraction, and quality of life. The cut-off point of 1STST was defined using ROC analysis. Results: With an intraclass correlation coefficient value of 0.975 [95 % confidence interval (CI) 0.954-0.986], the 1STST demonstrated excellent-test-retest reliability. Physiological responses after tests were similar in the 1STST and 6MWT (p > 0.05). The number of 1STST repetitions was strongly associated with 6MWT distance (r = 0.809; p < 0.001). A cut-off value of ≤13 repetitions in the number of 1STST repetitions was defined as functional impairment related to an increased risk of clinical events [sensitivity: 100 %, specificity: 84.6 %; AUC:0.94; 95 % CI 0.82 to 0.98; p < 0.001]. Conclusions: The 1STST is a reliable and valid assessment tool that produced comparable hemodynamic responses to the 6MWT in patients with AF. Considering its feasibility and time efficiency, healthcare professionals can use the 1STST rather than the 6MWT test to measure functional exercise status in a constrained environment for this patient group. (Copyright © 2024 Elsevier B.V. All rights reserved.) |
| Contributed Indexing: | Keywords: 6-min walk test;atrial fibrillation; Reliability; Sit-to-stand; Validity |
| Entry Date(s): | Date Created: 20241109 Date Completed: 20241205 Latest Revision: 20241205 |
| Update Code: | 20250114 |
| DOI: | 10.1016/j.ijcard.2024.132713 |
| PMID: | 39521179 |
| Databáza: | MEDLINE |
| Abstrakt: | Competing Interests: Declaration of competing interest None.<br />Background: The one-minute sit-to-stand test (1STST) is an easy-to-administer, space and time-saving test for determining functional exercise capacity in cardiac disease. This study aimed to investigate the 1STST -test-retest reliability and convergent validity and compare its physiological responses to the six-minute walk test (6MWT) in patients with Atrial fibrillation (AF).<br />Methods: Forty-five patients with AF were included in this study. Functional exercise capacity was evaluated using the 1STST and 6MWT. For assessing test-retest reliability, the intraclass correlation coefficient and Bland-Altman plots were utilised. Convergent validity was determined by correlation analysis 1 STST and 6MWT, age, European Heart Rhythm Association score, ejection fraction, and quality of life. The cut-off point of 1STST was defined using ROC analysis.<br />Results: With an intraclass correlation coefficient value of 0.975 [95 % confidence interval (CI) 0.954-0.986], the 1STST demonstrated excellent-test-retest reliability. Physiological responses after tests were similar in the 1STST and 6MWT (p > 0.05). The number of 1STST repetitions was strongly associated with 6MWT distance (r = 0.809; p < 0.001). A cut-off value of ≤13 repetitions in the number of 1STST repetitions was defined as functional impairment related to an increased risk of clinical events [sensitivity: 100 %, specificity: 84.6 %; AUC:0.94; 95 % CI 0.82 to 0.98; p < 0.001].<br />Conclusions: The 1STST is a reliable and valid assessment tool that produced comparable hemodynamic responses to the 6MWT in patients with AF. Considering its feasibility and time efficiency, healthcare professionals can use the 1STST rather than the 6MWT test to measure functional exercise status in a constrained environment for this patient group.<br /> (Copyright © 2024 Elsevier B.V. All rights reserved.) |
|---|---|
| ISSN: | 1874-1754 |
| DOI: | 10.1016/j.ijcard.2024.132713 |
Full Text Finder
Nájsť tento článok vo Web of Science