Evaluation of minimum residual pressure as design criterion for South African water distribution systems
The South African civil engineering fraternity has grown to accept 24 m as the design criterion for minimum residual pressure in water distribution systems. However, the theoretical peak demand in many systems has increased beyond the point where minimum residual pressure exceeds 24 m - at least acc...
Saved in:
| Published in: | Water SA Vol. 35; no. 1; pp. 183 - 191 |
|---|---|
| Main Authors: | , |
| Format: | Journal Article |
| Language: | English |
| Published: |
Water Research Commission (WRC)
01.01.2009
|
| Subjects: | |
| ISSN: | 0378-4738, 1816-7950 |
| Online Access: | Get full text |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Abstract | The South African civil engineering fraternity has grown to accept 24 m as the design criterion for minimum residual pressure in water distribution systems. However, the theoretical peak demand in many systems has increased beyond the point where minimum residual pressure exceeds 24 m - at least according to hydraulic models. Additions of customers to existing supply systems have led to increased peak flows with time, often without infrastructure upgrades to internal reticulation. Increased flows imply reduced pressures. This is not necessarily a concern: peak flow conditions rarely occur in a supply system and also, customer complaints often act as a first sign of 'low pressures'. No complaints imply 'no low pressures'. The researchers analysed hydraulic models for 14 different towns in 5 municipal areas of South Africa, including 2 large metros, to identify the minimum residual pressures currently expected. The results include almost 55 000 model nodes and show that about 20% of the nodes in the distribution systems analysed have pressures of below 24 m, while pressures of below 14 m are not uncommon. Whether this relatively common occurrence of low pressures under modelled peak demand is found in practice is not known at this stage. A new guideline for minimum residual pressure based on previous criteria and results from this study is presented, noting that a physical lower limit of about 10 m water pressure is specified in home appliance specifications. |
|---|---|
| AbstractList | The South African civil engineering fraternity has grown to accept 24 m as the design criterion for minimum residual pressure in water distribution systems. However, the theoretical peak demand in many systems has increased beyond the point where minimum residual pressure exceeds 24 m - at least according to hydraulic models. Additions of customers to existing supply systems have led to increased peak flows with time, often without infrastructure upgrades to internal reticulation. Increased flows imply reduced pressures. This is not necessarily a concern: peak flow conditions rarely occur in a supply system and also, customer complaints often act as a first sign of 'low pressures'. No complaints imply 'no low pressures'. The researchers analysed hydraulic models for 14 different towns in 5 municipal areas of South Africa, including 2 large metros, to identify the minimum residual pressures currently expected. The results include almost 55 000 model nodes and show that about 20% of the nodes in the distribution systems analysed have pressures of below 24 m, while pressures of below 14 m are not uncommon. Whether this relatively common occurrence of low pressures under modelled peak demand is found in practice is not known at this stage. A new guideline for minimum residual pressure based on previous criteria and results from this study is presented, noting that a physical lower limit of about 10 m water pressure is specified in home appliance specifications. |
| Author | Strijdom, J.L. Jacobs, H.E. |
| Author_xml | – sequence: 1 givenname: H.E. surname: Jacobs fullname: Jacobs, H.E. – sequence: 2 givenname: J.L. surname: Strijdom fullname: Strijdom, J.L. |
| BookMark | eNqljE1OwzAUhK2qSA3QO7wLRLKT5qfsqioIsYW99VI72MixIz-7iNuTIm7Aakbz6Zt7tvXB6w0rRC_asjs2fMsKXnd9eejqfsf2RJ-c80ocmurYFcwMV3QZkw0ewgSz9XbOM0RNVmV0sKyNctSABGodPzxcok063oQpRHgLORk4TdFe0MMXrgiUpRTtmH9f6ZuSnumR3U3oSO__8oE9PQ_v55eScLReJ0molzxKk9JC0ignDXrltLwxwZuKy-H1LETb8r7-l_wDT8JdxA |
| ContentType | Journal Article |
| DatabaseTitleList | |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Engineering Chemistry |
| EISSN | 1816-7950 |
| EndPage | 191 |
| ExternalDocumentID | https://hdl.handle.net/10520/EJC116608 |
| GroupedDBID | -OY 123 1RI 29R 2WC 4JU 4P2 6SC 7XC 88I 8CJ 8FE 8FG 8FH 8G5 8R4 8R5 A8Z AAFWJ ABDBF ABJCF ABUWG ACGFO ACGOD ACIHN ACIWK ACPRK ACUHS ADBBV AEAQA AENEX AEUYN AFFHD AFKRA AFPKN AFRAH ALMA_UNASSIGNED_HOLDINGS ANHLU APOWU ATCPS AZFZN AZQEC BBNVY BCNDV BENPR BGLVJ BHPHI BKSAR BPHCQ C1A CCPQU CWDGH D1J D1K DWQXO E3Z EBD EBS ECGQY EJD ESX GNUQQ GROUPED_DOAJ GUQSH GX1 HCIFZ HH5 IAO JRA K6- KQ8 KWQ L6V LK5 LK8 M2O M2P M7P M7R M7S OK1 OVT P2P PATMY PCBAR PHGZM PHGZT PIMPY PQGLB PQQKQ PROAC PTHSS PYCSY Q2X RFP RNS RXW SCD TR2 TUS XSB ~8M |
| ID | FETCH-sabinet_saepub_https_hdl_handle_net_10520_EJC1166083 |
| ISSN | 0378-4738 |
| IngestDate | Thu Nov 27 13:21:33 EST 2025 |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 1 |
| Language | English |
| LinkModel | OpenURL |
| MergedId | FETCHMERGED-sabinet_saepub_https_hdl_handle_net_10520_EJC1166083 |
| ParticipantIDs | sabinet_saepub_https_hdl_handle_net_10520_EJC116608 |
| PublicationCentury | 2000 |
| PublicationDate | 20090101 |
| PublicationDateYYYYMMDD | 2009-01-01 |
| PublicationDate_xml | – month: 01 year: 2009 text: 20090101 day: 01 |
| PublicationDecade | 2000 |
| PublicationTitle | Water SA |
| PublicationYear | 2009 |
| Publisher | Water Research Commission (WRC) |
| Publisher_xml | – name: Water Research Commission (WRC) |
| SSID | ssj0002145297 ssj0023349 |
| Score | 3.565639 |
| Snippet | The South African civil engineering fraternity has grown to accept 24 m as the design criterion for minimum residual pressure in water distribution systems.... |
| SourceID | sabinet |
| SourceType | Publisher |
| StartPage | 183 |
| SubjectTerms | Design standard Peak flow Residual pressure Water distribution system |
| Title | Evaluation of minimum residual pressure as design criterion for South African water distribution systems |
| URI | https://hdl.handle.net/10520/EJC116608 |
| Volume | 35 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVAON databaseName: DOAJ Directory of Open Access Journals customDbUrl: eissn: 1816-7950 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0023349 issn: 0378-4738 databaseCode: DOA dateStart: 20050101 isFulltext: true titleUrlDefault: https://www.doaj.org/ providerName: Directory of Open Access Journals – providerCode: PRVPQU databaseName: Biological Science Database customDbUrl: eissn: 1816-7950 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0023349 issn: 0378-4738 databaseCode: M7P dateStart: 20090101 isFulltext: true titleUrlDefault: http://search.proquest.com/biologicalscijournals providerName: ProQuest – providerCode: PRVPQU databaseName: Earth, Atmospheric & Aquatic Science Database customDbUrl: eissn: 1816-7950 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0023349 issn: 0378-4738 databaseCode: PCBAR dateStart: 20090101 isFulltext: true titleUrlDefault: https://search.proquest.com/eaasdb providerName: ProQuest – providerCode: PRVPQU databaseName: Engineering Database (subscription) customDbUrl: eissn: 1816-7950 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0023349 issn: 0378-4738 databaseCode: M7S dateStart: 20090101 isFulltext: true titleUrlDefault: http://search.proquest.com providerName: ProQuest – providerCode: PRVPQU databaseName: Environmental Science Database (subscripiton) customDbUrl: eissn: 1816-7950 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0023349 issn: 0378-4738 databaseCode: PATMY dateStart: 20090101 isFulltext: true titleUrlDefault: http://search.proquest.com/environmentalscience providerName: ProQuest – providerCode: PRVPQU databaseName: Middle East & Africa Database customDbUrl: eissn: 1816-7950 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0023349 issn: 0378-4738 databaseCode: CWDGH dateStart: 20090101 isFulltext: true titleUrlDefault: https://search.proquest.com/middleeastafrica providerName: ProQuest – providerCode: PRVPQU databaseName: PROQUEST customDbUrl: eissn: 1816-7950 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0023349 issn: 0378-4738 databaseCode: BENPR dateStart: 20090101 isFulltext: true titleUrlDefault: https://www.proquest.com/central providerName: ProQuest – providerCode: PRVPQU databaseName: Publicly Available Content Database customDbUrl: eissn: 1816-7950 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0023349 issn: 0378-4738 databaseCode: PIMPY dateStart: 20090101 isFulltext: true titleUrlDefault: http://search.proquest.com/publiccontent providerName: ProQuest – providerCode: PRVPQU databaseName: Research Library customDbUrl: eissn: 1816-7950 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0023349 issn: 0378-4738 databaseCode: M2O dateStart: 20090101 isFulltext: true titleUrlDefault: https://search.proquest.com/pqrl providerName: ProQuest – providerCode: PRVPQU databaseName: Science Database (ProQuest) customDbUrl: eissn: 1816-7950 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0023349 issn: 0378-4738 databaseCode: M2P dateStart: 20090101 isFulltext: true titleUrlDefault: https://search.proquest.com/sciencejournals providerName: ProQuest |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1LS8NAEF60CupBtCq-2YO3kNAkm8d6kxCpRUvRQusp5IkVmkrTan--s4-kaU8qCCWUPDbJfh-TndmdbxC6sUKDJA4LgdEkVUmSWSolKbgq1M5iPWtlhhnxYhNOt-sOh7QnZ0wLXk7AyXN3saAf_wo17AOwWersL-CuGoUd8B9Ahy3ADtsfAe9X-t187nyUj8bzsQJetUy74v41mzUolIQv31DAcDDFZrnmkBfVU0T9oFz5CnkNcSavKytjSfHnoj6sHfCzXio2dMDORpwhbc3XqigOtPGeTERetvaorUQc6FrEQTRZLgxkdgsYWQiyuoNnrwxhyKwsh0XvhIKLlgoj6-q26lAhOFtaYSFassI2YVJ1UehGfp11UdtrTSObswdgAGzgt6pRwUMTlsEWUvodT9dtm-WGb5ot0kBbvYen3msVk2Oq7QZdOuymKdyn8h3AR2K6x9BobQzSP0D70nnAdwL0Q7SR5k2045U1-5poryYveYTellTAkwxLKuCSCrikAg4LLKiAKypgoALmVMCSCphTAdepgCUVjtHtvd_32qp87qAIWa4lT-YqAuioQHRUwI7xbgqqTjJPUCOf5OkpwqZFYpoZoeWEDiGpE8Wt2M5IDMObOEot6wyZf7jB-Z-uukC7S1JeosZsOk-v0Hb8ORsV02sJ6TfaR3Q_ |
| linkProvider | ProQuest |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+minimum+residual+pressure+as+design+criterion+for+South+African+water+distribution+systems&rft.jtitle=Water+SA&rft.au=Jacobs%2C+H.E.&rft.au=Strijdom%2C+J.L.&rft.date=2009-01-01&rft.pub=Water+Research+Commission+%28WRC%29&rft.issn=0378-4738&rft.eissn=1816-7950&rft.volume=35&rft.issue=1&rft.spage=183&rft.epage=191&rft.externalDocID=https%3A%2F%2Fhdl.handle.net%2F10520%2FEJC116608 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0378-4738&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0378-4738&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0378-4738&client=summon |