Electrically tunable fluidic lens imaging system for laparoscopic fluorescence-guided surgery
The addition of fluorescence guidance in laparoscopic procedures has gained significant interest in recent years, particularly through the use of near infrared (NIR) markers. In this work we present a novel laparoscope camera coupler based on an electrically tunable fluidic lens that permits program...
Uložené v:
| Vydané v: | Biomedical optics express Ročník 8; číslo 7; s. 3232 - 3247 |
|---|---|
| Hlavní autori: | , , , , , , |
| Médium: | Journal Article |
| Jazyk: | English |
| Vydavateľské údaje: |
United States
Optical Society of America
01.07.2017
|
| Predmet: | |
| ISSN: | 2156-7085, 2156-7085 |
| On-line prístup: | Získať plný text |
| Tagy: |
Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
|
| Abstract | The addition of fluorescence guidance in laparoscopic procedures has gained significant interest in recent years, particularly through the use of near infrared (NIR) markers. In this work we present a novel laparoscope camera coupler based on an electrically tunable fluidic lens that permits programmable focus control and has desirable achromatic performance from the visible to the NIR. Its use extends the lower working distance limit and improves detection sensitivity, important for work with molecularly targeted fluorescence markers. We demonstrate its superior optical performance in laparoscopic fluorescence-guided surgery.
results using a tumor specific molecular probe and a nonspecific NIR dye are presented. |
|---|---|
| AbstractList | The addition of fluorescence guidance in laparoscopic procedures has gained significant interest in recent years, particularly through the use of near infrared (NIR) markers. In this work we present a novel laparoscope camera coupler based on an electrically tunable fluidic lens that permits programmable focus control and has desirable achromatic performance from the visible to the NIR. Its use extends the lower working distance limit and improves detection sensitivity, important for work with molecularly targeted fluorescence markers. We demonstrate its superior optical performance in laparoscopic fluorescence-guided surgery.
results using a tumor specific molecular probe and a nonspecific NIR dye are presented. The addition of fluorescence guidance in laparoscopic procedures has gained significant interest in recent years, particularly through the use of near infrared (NIR) markers. In this work we present a novel laparoscope camera coupler based on an electrically tunable fluidic lens that permits programmable focus control and has desirable achromatic performance from the visible to the NIR. Its use extends the lower working distance limit and improves detection sensitivity, important for work with molecularly targeted fluorescence markers. We demonstrate its superior optical performance in laparoscopic fluorescence-guided surgery. In vivo results using a tumor specific molecular probe and a nonspecific NIR dye are presented. The addition of fluorescence guidance in laparoscopic procedures has gained significant interest in recent years, particularly through the use of near infrared (NIR) markers. In this work we present a novel laparoscope camera coupler based on an electrically tunable fluidic lens that permits programmable focus control and has desirable achromatic performance from the visible to the NIR. Its use extends the lower working distance limit and improves detection sensitivity, important for work with molecularly targeted fluorescence markers. We demonstrate its superior optical performance in laparoscopic fluorescence-guided surgery. In vivo results using a tumor specific molecular probe and a nonspecific NIR dye are presented.The addition of fluorescence guidance in laparoscopic procedures has gained significant interest in recent years, particularly through the use of near infrared (NIR) markers. In this work we present a novel laparoscope camera coupler based on an electrically tunable fluidic lens that permits programmable focus control and has desirable achromatic performance from the visible to the NIR. Its use extends the lower working distance limit and improves detection sensitivity, important for work with molecularly targeted fluorescence markers. We demonstrate its superior optical performance in laparoscopic fluorescence-guided surgery. In vivo results using a tumor specific molecular probe and a nonspecific NIR dye are presented. |
| Author | Barber, Paul R Smart, Sean C Vojnovic, Borivoj Augustyniak, Edyta M Vallis, Katherine A Tullis, Iain D C Volpi, Davide |
| Author_xml | – sequence: 1 givenname: Davide surname: Volpi fullname: Volpi, Davide organization: CR-UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, OX3 7DQ, UK – sequence: 2 givenname: Iain D C surname: Tullis fullname: Tullis, Iain D C organization: CR-UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, OX3 7DQ, UK – sequence: 3 givenname: Paul R surname: Barber fullname: Barber, Paul R organization: CR-UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, OX3 7DQ, UK – sequence: 4 givenname: Edyta M surname: Augustyniak fullname: Augustyniak, Edyta M organization: CR-UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, OX3 7DQ, UK – sequence: 5 givenname: Sean C surname: Smart fullname: Smart, Sean C organization: CR-UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, OX3 7DQ, UK – sequence: 6 givenname: Katherine A surname: Vallis fullname: Vallis, Katherine A organization: CR-UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, OX3 7DQ, UK – sequence: 7 givenname: Borivoj surname: Vojnovic fullname: Vojnovic, Borivoj organization: CR-UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, OX3 7DQ, UK |
| BackLink | https://www.ncbi.nlm.nih.gov/pubmed/28717564$$D View this record in MEDLINE/PubMed |
| BookMark | eNpVUMtOwzAQtFARLaU3zihHLil-5OFckKAqD6lSL72iyHHWIcixg50g5e-xREFlL7vSzs7MziWaGWsAoWuC14Rlyd3jfrvma4wZZfQMLShJszjHPJ2dzHO08v4Dh0qSHDN-geaU5yRPs2SB3rYa5OBaKbSeomE0otIQKT22dSsjDcZHbSea1jSRn_wAXaSsi7TohbNe2j6AAtg68BKMhLgJh1BHfnQNuOkKnSuhPayOfYkOT9vD5iXe7Z9fNw-7uCdFNsQ0rzlVRZ4zSICQOmOqyCohoOK1UKSSNOEKY6VwJQsKhSoAE5oRJiGIcbZE9z-0_Vh1UAcngxO67F2w7qbSirb8vzHte9nYrzJNMec0DQS3RwJnP0fwQ9m14SGthQE7-pIUlIS8i4QF6M2p1p_Ib6TsGxyCfn4 |
| ContentType | Journal Article |
| Copyright | 2017 Optical Society of America 2017 Optical Society of America |
| Copyright_xml | – notice: 2017 Optical Society of America 2017 Optical Society of America |
| DBID | NPM 7X8 5PM |
| DOI | 10.1364/BOE.8.003232 |
| DatabaseName | PubMed MEDLINE - Academic PubMed Central (Full Participant titles) |
| DatabaseTitle | PubMed MEDLINE - Academic |
| DatabaseTitleList | PubMed MEDLINE - Academic |
| Database_xml | – sequence: 1 dbid: NPM name: PubMed url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: 7X8 name: MEDLINE - Academic url: https://search.proquest.com/medline sourceTypes: Aggregation Database |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Medicine Engineering |
| EISSN | 2156-7085 |
| EndPage | 3247 |
| ExternalDocumentID | PMC5508825 28717564 |
| Genre | Journal Article |
| GrantInformation_xml | – fundername: Cancer Research UK grantid: 11564 – fundername: Cancer Research UK grantid: 16466 – fundername: Cancer Research UK grantid: 15677 – fundername: Cancer Research UK grantid: 22906 – fundername: Oxford Cancer Imaging Centre (OCIC) grantid: H3R00010 – fundername: Cancer Research UK grantid: C1380/A18444; C5255/A15935 |
| GroupedDBID | 4.4 53G 8SL AAFWJ AAWJZ ADBBV AEDJG AENEX AFPKN AKGWG ALMA_UNASSIGNED_HOLDINGS AOIJS ATHME AYPRP AZSQR AZYMN BAWUL BCNDV DIK DSZJF E3Z EBS EJD GROUPED_DOAJ GX1 HYE KQ8 LPK M~E NPM O5R O5S OFLFD OK1 OPJBK ROL ROS RPM TR6 7X8 ABGOQ 5PM |
| ID | FETCH-LOGICAL-p196t-27d82f9773e4e11d63f96baaeb8daf1bc248f00ff0bc92e9f9e012613ceded83 |
| ISICitedReferencesCount | 23 |
| ISICitedReferencesURI | http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000404738300007&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| ISSN | 2156-7085 |
| IngestDate | Tue Nov 04 01:57:30 EST 2025 Sun Nov 09 11:06:54 EST 2025 Mon Jul 21 05:50:56 EDT 2025 |
| IsDoiOpenAccess | false |
| IsOpenAccess | true |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 7 |
| Keywords | (120.3620) Lens system design (170.0110) Imaging systems (170.6280) Spectroscopy, fluorescence and luminescence (120.4820) Optical systems (170.2150) Endoscopic imaging |
| Language | English |
| LinkModel | OpenURL |
| MergedId | FETCHMERGED-LOGICAL-p196t-27d82f9773e4e11d63f96baaeb8daf1bc248f00ff0bc92e9f9e012613ceded83 |
| Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| PMID | 28717564 |
| PQID | 1921136943 |
| PQPubID | 23479 |
| PageCount | 16 |
| ParticipantIDs | pubmedcentral_primary_oai_pubmedcentral_nih_gov_5508825 proquest_miscellaneous_1921136943 pubmed_primary_28717564 |
| PublicationCentury | 2000 |
| PublicationDate | 2017-07-01 |
| PublicationDateYYYYMMDD | 2017-07-01 |
| PublicationDate_xml | – month: 07 year: 2017 text: 2017-07-01 day: 01 |
| PublicationDecade | 2010 |
| PublicationPlace | United States |
| PublicationPlace_xml | – name: United States |
| PublicationTitle | Biomedical optics express |
| PublicationTitleAlternate | Biomed Opt Express |
| PublicationYear | 2017 |
| Publisher | Optical Society of America |
| Publisher_xml | – name: Optical Society of America |
| SSID | ssj0000447038 |
| Score | 2.2571716 |
| Snippet | The addition of fluorescence guidance in laparoscopic procedures has gained significant interest in recent years, particularly through the use of near infrared... |
| SourceID | pubmedcentral proquest pubmed |
| SourceType | Open Access Repository Aggregation Database Index Database |
| StartPage | 3232 |
| Title | Electrically tunable fluidic lens imaging system for laparoscopic fluorescence-guided surgery |
| URI | https://www.ncbi.nlm.nih.gov/pubmed/28717564 https://www.proquest.com/docview/1921136943 https://pubmed.ncbi.nlm.nih.gov/PMC5508825 |
| Volume | 8 |
| WOSCitedRecordID | wos000404738300007&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVAON databaseName: DOAJ Directory of Open Access Journals customDbUrl: eissn: 2156-7085 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0000447038 issn: 2156-7085 databaseCode: DOA dateStart: 20110101 isFulltext: true titleUrlDefault: https://www.doaj.org/ providerName: Directory of Open Access Journals – providerCode: PRVHPJ databaseName: ROAD: Directory of Open Access Scholarly Resources customDbUrl: eissn: 2156-7085 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0000447038 issn: 2156-7085 databaseCode: M~E dateStart: 20100101 isFulltext: true titleUrlDefault: https://road.issn.org providerName: ISSN International Centre |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lj9MwELa6C0JwQLC8yqMyErcoJQ8njo9LKeLSZYV66AVVie3sRuomUdusuhf-Ff-P8SNp9nEAJC5RmtiONPN1PLZnvkHoQ5CTIA3TxAVvNXRJJKmbkpy4PqFenLFEBDzTxSboyUmyWLDTweBXmwtzuaJlmex2rP6vqoZnoGyVOvsX6u4GhQdwD0qHK6gdrn-k-KkubKNkvwLPsjG5UfmqKUTBHZhjNk5xYUoTGRZnHWi4gjlT8VpWNTSCxtVa0zxx6Z5BR3BKN7fTpz_pzH2t5KrWbM9yV3cRHaqIV7Wqiy5wvkPQXJ0_GeOUFqXzeexMxvsN1XVmQKRCFp3v3Yvj5qzZbK_KIjXmW1xtU2c27m9a-LQLcLVL3Nps1LeRqcrpNgdUZlrS9g-ckdilnqno0xrrpIdJ2jO8YWC3SaX9aXg8b00QYUxU2Pu36VjF0La9erCoLzQu1EKSRoZg_QYh9-lsEim3NogO0L2ARkwZ09nP_daeRwDoYWLTLOCLH_vfU_TTdvC7VjU3g3N73s78CXpslyn42MDrKRrI8gg96pFXHqEHMxuW8Qz96GMOW8xhizmsMIct5rDBHAbM4T7m8B2YwxZzz9H8y3Q--erauh1uDfZ86wZUJEEOC4tQEun7Ig5zFmdpKrNEpLmf8YAkuefluZdxFkiWMwluEviVXMLgSfgCHZZVKV8hTITgMY8zwRknUZozlZcJo4VchLAOF0P0vhXgEsyiOutKS1k1m6Wi-QPRMxIO0Usj0GVt-FuWrfiHiF4TdddAUa5ff1MW55p63Sr-9T_3fIMe7v8Pb9Hhdt3Id-g-v9wWm_UIHdBFMtL7QiONqd-dmbJ9 |
| linkProvider | ISSN International Centre |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Electrically+tunable+fluidic+lens+imaging+system+for+laparoscopic+fluorescence-guided+surgery&rft.jtitle=Biomedical+optics+express&rft.au=Volpi%2C+Davide&rft.au=Tullis%2C+Iain+D.+C.&rft.au=Barber%2C+Paul+R.&rft.au=Augustyniak%2C+Edyta+M.&rft.date=2017-07-01&rft.pub=Optical+Society+of+America&rft.eissn=2156-7085&rft.volume=8&rft.issue=7&rft.spage=3232&rft.epage=3247&rft_id=info:doi/10.1364%2FBOE.8.003232&rft_id=info%3Apmid%2F28717564&rft.externalDocID=PMC5508825 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2156-7085&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2156-7085&client=summon |