뇌졸중으로 인한 편마비 환자의 보행평가를 위한 체중심 가속도센서 기반의 새로운 보 검출 알고리즘 개발

In this study, we have developed a novel step detection algorithm for gait evaluation of patients with hemiplegia based on trunk accelerometry device. For this, we have used a bandpass filter and a least square acceleration (LSA) filter which is characterized by emphasizing the peak or valley point...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:Journal of biomedical engineering research Ročník 30; číslo 3; s. 213 - 220
Hlavní autori: 이효기, 황성재, 조성필, 이동률, 유승현, 이경중, 김영호, 정하중, Lee, Hyo-Ki, Hwang, Sung-Jae, Cho, Sung-Pil, Lee, Dong-Ryul, You, Sung-Hyun, Lee, Kyoung-Joung, Kim, Young-Ho, Chung, Ha-Joong
Médium: Journal Article
Jazyk:Korean
Vydavateľské údaje: 대한의용생체공학회 01.06.2009
Predmet:
ISSN:1229-0807, 2288-9396
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Abstract In this study, we have developed a novel step detection algorithm for gait evaluation of patients with hemiplegia based on trunk accelerometry device. For this, we have used a bandpass filter and a least square acceleration (LSA) filter which is characterized by emphasizing the peak or valley point of the acceleration signals for each 3-axis accelerometer signals. To evaluate the algorithm, the detected steps by developed algorithm and real steps by the motion analysis system were compared. As a result, we could obtain the sensitivity of 96.44%, the specificity of 99.94% and the accuracy of 99.90% for the patients' data sets and the sensitivity of 100%, the specificity of 99.93% and the accuracy of 99.93% for the normal data sets. In conclusion, the developed algorithm is useful for the step detection for patients with hemiplegia as well as normal subjects.
AbstractList In this study, we have developed a novel step detection algorithm for gait evaluation of patients with hemiplegia based on trunk accelerometry device. For this, we have used a bandpass filter and a least square acceleration (LSA) filter which is characterized by emphasizing the peak or valley point of the acceleration signals for each 3-axis accelerometer signals. To evaluate the algorithm, the detected steps by developed algorithm and real steps by the motion analysis system were compared. As a result, we could obtain the sensitivity of 96.44%, the specificity of 99.94% and the accuracy of 99.90% for the patients’ data sets and the sensitivity of 100%, the specificity of 99.93% and the accuracy of 99.93% for the normal data sets. In conclusion, the developed algorithm is useful for the step detection for patients with hemiplegia as well as normal subjects. In this study, we have developed a novel step detection algorithm for gait evaluation of patients with hemiplegia based on trunk accelerometry device. For this, we have used a bandpass filter and a least square acceleration (LSA) filter which is characterized by emphasizing the peak or valley point of the acceleration signals for each 3-axis accelerometer signals. To evaluate the algorithm, the detected steps by developed algorithm and real steps by the motion analysis system were compared. As a result, we could obtain the sensitivity of 96.44%, the specificity of 99.94% and the accuracy of 99.90% for the patients’ data sets and the sensitivity of 100%, the specificity of 99.93% and the accuracy of 99.93% for the normal data sets. In conclusion, the developed algorithm is useful for the step detection for patients with hemiplegia as well as normal subjects. KCI Citation Count: 8
In this study, we have developed a novel step detection algorithm for gait evaluation of patients with hemiplegia based on trunk accelerometry device. For this, we have used a bandpass filter and a least square acceleration (LSA) filter which is characterized by emphasizing the peak or valley point of the acceleration signals for each 3-axis accelerometer signals. To evaluate the algorithm, the detected steps by developed algorithm and real steps by the motion analysis system were compared. As a result, we could obtain the sensitivity of 96.44%, the specificity of 99.94% and the accuracy of 99.90% for the patients' data sets and the sensitivity of 100%, the specificity of 99.93% and the accuracy of 99.93% for the normal data sets. In conclusion, the developed algorithm is useful for the step detection for patients with hemiplegia as well as normal subjects.
Author Cho, Sung-Pil
정하중
유승현
Lee, Kyoung-Joung
이경중
조성필
Hwang, Sung-Jae
김영호
Kim, Young-Ho
You, Sung-Hyun
이동률
황성재
Lee, Dong-Ryul
이효기
Chung, Ha-Joong
Lee, Hyo-Ki
Author_xml – sequence: 1
  fullname: 이효기
– sequence: 2
  fullname: 황성재
– sequence: 3
  fullname: 조성필
– sequence: 4
  fullname: 이동률
– sequence: 5
  fullname: 유승현
– sequence: 6
  fullname: 이경중
– sequence: 7
  fullname: 김영호
– sequence: 8
  fullname: 정하중
– sequence: 9
  fullname: Lee, Hyo-Ki
– sequence: 10
  fullname: Hwang, Sung-Jae
– sequence: 11
  fullname: Cho, Sung-Pil
– sequence: 12
  fullname: Lee, Dong-Ryul
– sequence: 13
  fullname: You, Sung-Hyun
– sequence: 14
  fullname: Lee, Kyoung-Joung
– sequence: 15
  fullname: Kim, Young-Ho
– sequence: 16
  fullname: Chung, Ha-Joong
BackLink https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001351562$$DAccess content in National Research Foundation of Korea (NRF)
BookMark eNotjF9LwlAYh0cYZOZ32E3QzeDsHM_ZzqVIfyxBKO_H1C3WRMH1AYRGKZnWhbFiRkLZjReiEgv8RDtn36Ete29-8PI8z66QaraaxpaQhlBVJYooSQlpGUIqARUoO0LWca5AfARgjGhaGLC7Pp8E_OOJ-2s28UU-DqKRL0aDgH112Y8rRi8ef3vkY09ky1X03IuGvXDeYZ9rkftugvLFKtHvZ2L857cPbOhyd81dXwyDOZt7icpvunGcv66SiBguOvw7Fkf9cPnOpjM-9WLXZ3N_T9g29YZjZP83I1wcHVYKJ1KpfFws5EuSTRCScjVKCAJVUEOqAg0F5EzZxJBg2cCmDBCoAwgMVK9BXTUpNghSqhAgg-oA67SKMsLBptpsm5pds7SWbv3tZUuz21r-vFLUFFVVMIrR_Q1qW861pTXrTkM7zZ-VIQAU5hSEZEUmmKBfc6OaUg
ContentType Journal Article
DBID JDI
ACYCR
DEWEY 610.28
DatabaseName KoreaScience
Korean Citation Index
DatabaseTitleList

DeliveryMethod fulltext_linktorsrc
Discipline Medicine
Engineering
DocumentTitleAlternate Development of a Novel Step Detection Algorithm for Gait Evaluation of Patients with Hemiplegia Based on Trunk Accelerometer
EISSN 2288-9396
EndPage 220
ExternalDocumentID oai_kci_go_kr_ARTI_788753
JAKO200924733171656
GroupedDBID 9ZL
ALMA_UNASSIGNED_HOLDINGS
JDI
ACYCR
ID FETCH-LOGICAL-k633-4c96630b0c3872e704f1f52651e5f1030d020e3dc2a8f95e637b203e9a05a9b3
ISSN 1229-0807
IngestDate Sun Mar 09 07:52:57 EDT 2025
Fri Dec 22 12:04:09 EST 2023
IsOpenAccess true
IsPeerReviewed false
IsScholarly false
Issue 3
Keywords Step detection
Accelerometer
Least square acceleration filter
Gait assessment
Motion analysis system
Language Korean
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-k633-4c96630b0c3872e704f1f52651e5f1030d020e3dc2a8f95e637b203e9a05a9b3
Notes KISTI1.1003/JNL.JAKO200924733171656
G704-000351.2009.30.3.007
OpenAccessLink http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO200924733171656&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
PageCount 8
ParticipantIDs nrf_kci_oai_kci_go_kr_ARTI_788753
kisti_ndsl_JAKO200924733171656
PublicationCentury 2000
PublicationDate 2009-06
PublicationDateYYYYMMDD 2009-06-01
PublicationDate_xml – month: 06
  year: 2009
  text: 2009-06
PublicationDecade 2000
PublicationTitle Journal of biomedical engineering research
PublicationTitleAlternate Journal of biomedical engineering research : the official journal of the Korean Society of Medical & Biological Engineering
PublicationYear 2009
Publisher 대한의용생체공학회
Publisher_xml – name: 대한의용생체공학회
SSID ssj0000605539
ssib053377025
ssib030194549
ssib036278799
ssib044763777
Score 1.4268225
Snippet In this study, we have developed a novel step detection algorithm for gait evaluation of patients with hemiplegia based on trunk accelerometry device. For...
SourceID nrf
kisti
SourceType Open Website
Open Access Repository
StartPage 213
SubjectTerms 의공학
Title 뇌졸중으로 인한 편마비 환자의 보행평가를 위한 체중심 가속도센서 기반의 새로운 보 검출 알고리즘 개발
URI http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO200924733171656&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001351562
Volume 30
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX 의공학회지, 2009, 30(3), , pp.213-220
journalDatabaseRights – providerCode: PRVHPJ
  databaseName: ROAD: Directory of Open Access Scholarly Resources
  customDbUrl:
  eissn: 2288-9396
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssib044763777
  issn: 1229-0807
  databaseCode: M~E
  dateStart: 20060101
  isFulltext: true
  titleUrlDefault: https://road.issn.org
  providerName: ISSN International Centre
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1LaxRBEB5i8KAH8YnxEUawLy4rs_PsPs7MbvAZBXPIbdl5rIQNG9nEkJMEXDTBmOghsspGDGi85LAkQVbIL9qZ_Q9W1zwjBOLBy9JUV31dXTW9XT2PKkG4rTp6zXNrctH1XL2oQoRQdGrMKToQncN26fmujynzHxmTk3R6mj0dGb2TfAuzOGs0m3Rpib34r64GGjibfzr7D-5OQYEAbXA6_ILb4fdEjicVi8AJn9qkYhOzRCyKDZWwEm8wm1g254EuZheQVEamMmFaRCoTWkEScAESNixGqIp9jBGGmKxCmBQDMFpALoVYKjLphDJEmsCGSSyJv1XBITXQoBDrQtX8wKCbjAA5hSlI8L4UAUgAXsZ5TiAAwlh23GAxN-UCXCcp0TdWE7iUeFZoBOwDATWbQoQgx-NZemoqDQ1rci4zmo0O6qHCeoSOejI7Gdk-JvyP8h7gEvGznJCFOPlSepM-8U9kJpOYNJ1bxoI-MVliiFLsnCytZg4Fp2WVUxPnWfjVIuVQ0DFRbb30zhDL3mDDtYxusNFQsR9TU8d2jRVTODHzMJrQ0hIpFs-P2rltUpZhNBrVK77rI02WYSEyhR3dDpVcZCXLUhZ1JG9a_BWMHEl73nBnqs_nqo1WFQ5396v8xVdNOSWcUiReJePxq0qyc8AuxdTc82qIymAjyg7aqgrbaC7xJZxxDCN5vh7FbJKmYdnBdGpwWuVHuBkIOputei7onDovnIsvF9GMVvkFYaQxd1E4m8sheklYD96uhdv98PvHsHsYbHfFcKs_3OyKw_V-8HMl-N0Wh5874dcP4VZHDPYPhp9Whxurg95y8ONQDLttzhruHXDxd7si0MM374ONdtg-DNtdcdDvBb0OFw1frwB4-OWAg4iDveXwFwhurg32vwU7u-FOB2S7Qa97WXg2UZmy7xXjIivFhq4oRdVlcOaQHMlVqCH7hqTWS3VeMqPka3VegtCD86SveK5co3Wm-WBGR5YUn9UkDf7TlSvCaHOu6V8VRN2lDqtTw1FcqvqOx3hqwJJHXU33NdkxxoRxtGe16c3PVh-YD59gwjeVF401eA6wMeEWGBqdfqzzr52A57pwJlsNN4TRhdZL_6Zw2l1cmJlvjeN18wctsPn_
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%EB%87%8C%EC%A1%B8%EC%A4%91%EC%9C%BC%EB%A1%9C+%EC%9D%B8%ED%95%9C+%ED%8E%B8%EB%A7%88%EB%B9%84+%ED%99%98%EC%9E%90%EC%9D%98+%EB%B3%B4%ED%96%89%ED%8F%89%EA%B0%80%EB%A5%BC+%EC%9C%84%ED%95%9C+%EC%B2%B4%EC%A4%91%EC%8B%AC+%EA%B0%80%EC%86%8D%EB%8F%84%EC%84%BC%EC%84%9C+%EA%B8%B0%EB%B0%98%EC%9D%98+%EC%83%88%EB%A1%9C%EC%9A%B4+%EB%B3%B4+%EA%B2%80%EC%B6%9C+%EC%95%8C%EA%B3%A0%EB%A6%AC%EC%A6%98+%EA%B0%9C%EB%B0%9C&rft.jtitle=Journal+of+biomedical+engineering+research&rft.au=%EC%9D%B4%ED%9A%A8%EA%B8%B0&rft.au=%ED%99%A9%EC%84%B1%EC%9E%AC&rft.au=%EC%9D%B4%EA%B2%BD%EC%A4%91&rft.au=%EC%A1%B0%EC%84%B1%ED%95%84&rft.date=2009-06-01&rft.pub=%EB%8C%80%ED%95%9C%EC%9D%98%EC%9A%A9%EC%83%9D%EC%B2%B4%EA%B3%B5%ED%95%99%ED%9A%8C&rft.issn=1229-0807&rft.eissn=2288-9396&rft.spage=213&rft.epage=220&rft.externalDBID=n%2Fa&rft.externalDocID=oai_kci_go_kr_ARTI_788753
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1229-0807&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1229-0807&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1229-0807&client=summon