Distributed Photovoltaic Island Monitoring Method Based on Gated Loop Unit
The rapid deployment of distributed photovoltaic (PV) systems has introduced new challenges in islanding detection, a critical task for grid stability and safety. This paper presents a novel Distributed Photovoltaic Island Monitoring Method Based on Gated Loop Unit (GLU). The GLU leverages advanced...
Uloženo v:
| Vydáno v: | IEEE ... Information Technology and Mechatronics Engineering Conference (ITOEC ... ) (Online) Ročník 8; s. 1249 - 1252 |
|---|---|
| Hlavní autoři: | , , |
| Médium: | Konferenční příspěvek |
| Jazyk: | angličtina |
| Vydáno: |
IEEE
14.03.2025
|
| Témata: | |
| ISSN: | 2693-289X |
| On-line přístup: | Získat plný text |
| Tagy: |
Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
|
| Abstract | The rapid deployment of distributed photovoltaic (PV) systems has introduced new challenges in islanding detection, a critical task for grid stability and safety. This paper presents a novel Distributed Photovoltaic Island Monitoring Method Based on Gated Loop Unit (GLU). The GLU leverages advanced signal processing and dynamic response mechanisms to enhance detection sensitivity and accuracy. The proposed distributed architecture enables real-time data acquisition and collaborative decision-making across PV nodes, ensuring reliable monitoring under diverse grid conditions. Simulations and case studies validate the method's effectiveness, demonstrating superior performance in terms of detection accuracy, low latency, and robustness when compared to conventional techniques. The proposed approach provides a scalable and efficient solution for improving islanding detection in distributed PV systems, contributing to the development of resilient and intelligent power grids. |
|---|---|
| AbstractList | The rapid deployment of distributed photovoltaic (PV) systems has introduced new challenges in islanding detection, a critical task for grid stability and safety. This paper presents a novel Distributed Photovoltaic Island Monitoring Method Based on Gated Loop Unit (GLU). The GLU leverages advanced signal processing and dynamic response mechanisms to enhance detection sensitivity and accuracy. The proposed distributed architecture enables real-time data acquisition and collaborative decision-making across PV nodes, ensuring reliable monitoring under diverse grid conditions. Simulations and case studies validate the method's effectiveness, demonstrating superior performance in terms of detection accuracy, low latency, and robustness when compared to conventional techniques. The proposed approach provides a scalable and efficient solution for improving islanding detection in distributed PV systems, contributing to the development of resilient and intelligent power grids. |
| Author | Li, Zhukun Ao, Jianyong Li, Yanping |
| Author_xml | – sequence: 1 givenname: Jianyong surname: Ao fullname: Ao, Jianyong organization: Yangjiang Power Supply Bureau of Guangdong Power Grid Co., Ltd.,Yangjiang,China,529500 – sequence: 2 givenname: Yanping surname: Li fullname: Li, Yanping organization: Yangjiang Power Supply Bureau of Guangdong Power Grid Co., Ltd.,Yangjiang,China,529500 – sequence: 3 givenname: Zhukun surname: Li fullname: Li, Zhukun organization: NARI Technology Co., Ltd.,Nanjing,China,210000 |
| BookMark | eNo1j9FKwzAYhaMoOOfewIu8QGuSv03zX2rdZmVjXkzwbiRN6iKzGU0UfHsrKufiwOE7B84lOetD7wihnOWcM7xptpt5LUEymQsmynzMpOIST8gMK1QAvBRYKHFKJkIiZELhywWZxfjGGAPBABVOyOO9j2nw5iM5S5_2IYXPcEjat7SJB91bug69T2Hw_Stdu7QPlt7pOLKhp0v9U1qFcKTPI3RFzjt9iG7251OyXcy39UO22iyb-naVeYSUoUVT6UJp2wIrrGEtmJIXnay6UpsOWqygtKMKA62sJHcCR9RygZ1RvIIpuf6d9c653XHw73r42v2_h2__EVFu |
| ContentType | Conference Proceeding |
| DBID | 6IE 6IL CBEJK RIE RIL |
| DOI | 10.1109/ITOEC63606.2025.10968169 |
| DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present |
| DatabaseTitleList | |
| Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://ieeexplore.ieee.org/ sourceTypes: Publisher |
| DeliveryMethod | fulltext_linktorsrc |
| EISBN | 9798331529482 |
| EISSN | 2693-289X |
| EndPage | 1252 |
| ExternalDocumentID | 10968169 |
| Genre | orig-research |
| GroupedDBID | 6IE 6IF 6IL 6IN AAWTH ABLEC ADZIZ ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK CHZPO IEGSK OCL RIE RIL |
| ID | FETCH-LOGICAL-i93t-9d9b7a48adc304db0c3b514f67f5abf3c9735d5d54b3c6761e29dc3d129fb8173 |
| IEDL.DBID | RIE |
| IngestDate | Wed Apr 30 05:50:36 EDT 2025 |
| IsPeerReviewed | false |
| IsScholarly | false |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-i93t-9d9b7a48adc304db0c3b514f67f5abf3c9735d5d54b3c6761e29dc3d129fb8173 |
| PageCount | 4 |
| ParticipantIDs | ieee_primary_10968169 |
| PublicationCentury | 2000 |
| PublicationDate | 2025-March-14 |
| PublicationDateYYYYMMDD | 2025-03-14 |
| PublicationDate_xml | – month: 03 year: 2025 text: 2025-March-14 day: 14 |
| PublicationDecade | 2020 |
| PublicationTitle | IEEE ... Information Technology and Mechatronics Engineering Conference (ITOEC ... ) (Online) |
| PublicationTitleAbbrev | ITOEC |
| PublicationYear | 2025 |
| Publisher | IEEE |
| Publisher_xml | – name: IEEE |
| SSID | ssj0003203989 |
| Score | 1.9019415 |
| Snippet | The rapid deployment of distributed photovoltaic (PV) systems has introduced new challenges in islanding detection, a critical task for grid stability and... |
| SourceID | ieee |
| SourceType | Publisher |
| StartPage | 1249 |
| SubjectTerms | Accuracy artificial frog spring algorithm Distributed photovoltaic gated loop unit Islanding Logic gates machine learning Monitoring Photovoltaic systems Power system stability Signal processing Springs Stability analysis Time factors |
| Title | Distributed Photovoltaic Island Monitoring Method Based on Gated Loop Unit |
| URI | https://ieeexplore.ieee.org/document/10968169 |
| Volume | 8 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LTwMhECa28eBJjTW-w8ErdVlYHlerjRqtPfTQW7O8Yi9LU7f-fhn6MB48GC6EQEKGDDMM882H0K1hvnI-cFLrKhCuaCDpGWFIsMFVQfFaGpvJJuRopKZTPd6A1TMWxnufk898H7r5L99Fu4JQWdJwLRQVuoM6Uoo1WGsXUGFlwbTS22ydQt89T94fB1APC1IRyqq_Xf6LSCXbkeHhP3dwhHo_iDw83tmaY7TnmxP08gBVb4Gwyjs8_ohtTHdNeupbDAfdOLxWWIjc4bfMFI3vk9FyODYYomYOv8a4wOB29tBk-DgZPJENNwKZa9YS7bSRNVe1s6zgzhSWmeT6BCFDVZvArJascqlxw6yQgvpSp6kuWfdgFJXsFHWb2PgzhAWjVoQ6uXHe8sAA10EDKHJpBNeuOEc9kMNssa5-MduK4OKP8Ut0ANKGPC3Kr1C3Xa78Ndq3X-38c3mTz-wbqkmYfw |
| linkProvider | IEEE |
| linkToHtml | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV07T8MwELagIMEEiCLeeGBNSWLHj5XSqoW2dMjQrYpfoktSlZTfj89NixgYkBfLsizrrPOdz_fdh9CjIjYz1tGokJmLqEhc5J8RKnLamcwJWnClA9kEn0zEbCanDVg9YGGstSH5zHagG_7yTaXXECrzGi6ZSJjcRwdAndXAtXYhFZLGRAq5zdeJ5dMwf-91oSIWJCOkWWe7wC8qlWBJ-if_3MMpav9g8vB0Z23O0J4tz9HrC9S9Bcoqa_D0o6orf9v4x77GcNSlwRuVhdgdHgeuaPzszZbBVYkhbmbwqKqWGBzPNsr7vbw7iBp2hGghSR1JIxUvqCiMJjE1KtZEeefHMe6yQjmiJSeZ8Y0qohlniU2ln2q8fXdKJJxcoFZZlfYSYUYSzVzhHTmrqSOA7EgcqHKqGJUmvkJtkMN8ual_Md-K4PqP8Qd0NMjHo_loOHm7QccgecjaSugtatWrtb1Dh_qrXnyu7sP5fQPPJJvI |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=IEEE+...+Information+Technology+and+Mechatronics+Engineering+Conference+%28ITOEC+...+%29+%28Online%29&rft.atitle=Distributed+Photovoltaic+Island+Monitoring+Method+Based+on+Gated+Loop+Unit&rft.au=Ao%2C+Jianyong&rft.au=Li%2C+Yanping&rft.au=Li%2C+Zhukun&rft.date=2025-03-14&rft.pub=IEEE&rft.eissn=2693-289X&rft.volume=8&rft.spage=1249&rft.epage=1252&rft_id=info:doi/10.1109%2FITOEC63606.2025.10968169&rft.externalDocID=10968169 |