A strategic multi-step PMU allocation based on direct monitoring for smart grid (SG) implementation
The utilization of phasor measurement unit (PMU) is highly recognized in modern power industry for its smart measurement capability. To implement a smart transmission network, PMU should be allocated at all buses but for large power systems, PMU allocation at all buses is a matter of huge investment...
Saved in:
| Published in: | 2017 IEEE Transportation Electrification Conference (ITEC-India) pp. 1 - 6 |
|---|---|
| Main Authors: | , |
| Format: | Conference Proceeding |
| Language: | English |
| Published: |
IEEE
01.12.2017
|
| Subjects: | |
| Online Access: | Get full text |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Abstract | The utilization of phasor measurement unit (PMU) is highly recognized in modern power industry for its smart measurement capability. To implement a smart transmission network, PMU should be allocated at all buses but for large power systems, PMU allocation at all buses is a matter of huge investment and it should be conducted in certain number of steps. In this paper, an effective and practical multi-step PMU allocation strategy is proposed for IEEE 30-bus test system. In, the proposed strategy, the multi-step PMU allocation is framed in such a way that the important and preferred buses will be directly monitored during the initial and intermediate steps. In this paper, several strategies such as optimal PMU allocation (OPA) for full observability, important and critical bus preferences are taken into account. An efficient binary crow search algorithm (BCSA) is developed to solve the OPA problem and the developed algorithm is compared with other metaheuristic algorithms to show its efficiency. |
|---|---|
| AbstractList | The utilization of phasor measurement unit (PMU) is highly recognized in modern power industry for its smart measurement capability. To implement a smart transmission network, PMU should be allocated at all buses but for large power systems, PMU allocation at all buses is a matter of huge investment and it should be conducted in certain number of steps. In this paper, an effective and practical multi-step PMU allocation strategy is proposed for IEEE 30-bus test system. In, the proposed strategy, the multi-step PMU allocation is framed in such a way that the important and preferred buses will be directly monitored during the initial and intermediate steps. In this paper, several strategies such as optimal PMU allocation (OPA) for full observability, important and critical bus preferences are taken into account. An efficient binary crow search algorithm (BCSA) is developed to solve the OPA problem and the developed algorithm is compared with other metaheuristic algorithms to show its efficiency. |
| Author | Acharjee, P. Maji, Tapas Kumar |
| Author_xml | – sequence: 1 givenname: Tapas Kumar surname: Maji fullname: Maji, Tapas Kumar email: tapas.k.maji@gmail.com organization: Dept. of Electr. Eng., Nat. Inst. of Technol. Durgapur, Durgapur, India – sequence: 2 givenname: P. surname: Acharjee fullname: Acharjee, P. email: parimal.acharjee@ee.nitdgp.ac.in organization: Dept. of Electr. Eng., Nat. Inst. of Technol. Durgapur, Durgapur, India |
| BookMark | eNotjztPwzAYRY0EA5T-AgY8wpDgR-LHWEWlRCoCiTBXjv0lspTYlWMG_j0V7XTvcq7OvUPXIQZA6JGSklKiX9pu2xRtcN6UjFBZKs65YvoKrbVUtOZKMCGUvkV2g5ecTIbRWzz_TNkXS4Yj_nz_xmaaojXZx4B7s4DDp-J8ApvxHIPPMfkw4iEmvMwmZTwm7_DT1-4Z-_k4wQwh_9P36GYw0wLrS65Q97rtmrdi_7Frm82-8JrkohJ0YKBY75QUICvtZGUdOCkq52xte2GpINQpUxlqBiC9MLzmVtQDVYYpvkIP51kPAIdj8iep38PlOf8DHnlVlw |
| ContentType | Conference Proceeding |
| DBID | 6IE 6IL CBEJK RIE RIL |
| DOI | 10.1109/ITEC-India.2017.8333829 |
| DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Xplore IEEE Proceedings Order Plans (POP All) 1998-Present |
| DatabaseTitleList | |
| Database_xml | – sequence: 1 dbid: RIE name: IEEE Xplore Digital Library url: https://ieeexplore.ieee.org/ sourceTypes: Publisher |
| DeliveryMethod | fulltext_linktorsrc |
| EISBN | 9781538626689 1538626683 |
| EndPage | 6 |
| ExternalDocumentID | 8333829 |
| Genre | orig-research |
| GroupedDBID | 6IE 6IL CBEJK RIE RIL |
| ID | FETCH-LOGICAL-i90t-461f2e82bd876e749d74cded764ddc5cb6c1601d8a4a1afe0b6a353c65f18a283 |
| IEDL.DBID | RIE |
| IngestDate | Thu Jun 29 18:39:49 EDT 2023 |
| IsPeerReviewed | false |
| IsScholarly | false |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-i90t-461f2e82bd876e749d74cded764ddc5cb6c1601d8a4a1afe0b6a353c65f18a283 |
| PageCount | 6 |
| ParticipantIDs | ieee_primary_8333829 |
| PublicationCentury | 2000 |
| PublicationDate | 2017-Dec. |
| PublicationDateYYYYMMDD | 2017-12-01 |
| PublicationDate_xml | – month: 12 year: 2017 text: 2017-Dec. |
| PublicationDecade | 2010 |
| PublicationTitle | 2017 IEEE Transportation Electrification Conference (ITEC-India) |
| PublicationTitleAbbrev | ITEC-India |
| PublicationYear | 2017 |
| Publisher | IEEE |
| Publisher_xml | – name: IEEE |
| Score | 1.6408318 |
| Snippet | The utilization of phasor measurement unit (PMU) is highly recognized in modern power industry for its smart measurement capability. To implement a smart... |
| SourceID | ieee |
| SourceType | Publisher |
| StartPage | 1 |
| SubjectTerms | binary crow search algorithm (BCSA) Conferences Generators Monitoring Multi-step PMU allocation optimal PMU allocation (OPA) phasor measurement unit (PMU) Phasor measurement units Resource management Transportation Voltage measurement |
| Title | A strategic multi-step PMU allocation based on direct monitoring for smart grid (SG) implementation |
| URI | https://ieeexplore.ieee.org/document/8333829 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1NSwMxEA1t8eBJpRW1Kjl4UDBt0-xuNkcpVgUtBav0VpJMVvbQbemHv99Jdq0IXryFZcPCTGbfzOTNDCFXCr02E2uDhqQ0BigZMMONYNA3QnNhOA_tmt6f5WiUTqdqXCO3u1oY51wgn7mOX4a7fFjYrU-VdVOBAVVf1UldSlnWalWULd5TXTT1AXsqUKyesSU71du_xqYE1Bge_O97h6T1U35HxztgOSI1VzSJvaPrqpOspYEGyFBBSzp-eaP-8rxMvVGPSkBxUWIVnQeb9ck7iu4pXc_xqNCPVQ70-vXhhubzb_64390ik-H9ZPDIqgkJLFe9DYsSnvUdChvwn-ZkpEBGFhzIJAKwsTWJ5RhwQaojzXXmeibRIhY2iTOeanQsjkmjWBTuhFAllZEI7QJ8gGGkllz75mLo3glIlD0lTS-f2bLsgTGrRHP29-M22fcqKGkf56SxWW3dBdmzn5t8vboMivsCMHqcmA |
| linkProvider | IEEE |
| linkToHtml | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LS8NAEB5qFfSk0opv9-BBwbTdbJLNHqVYW2xLwSq9lX1Fcmha-vD3O5vEiuDF2xKyBGZ28s3MfjMDcCvQa1OhVGhIQmKAkhhPUcU84ysmKVOU5u2a3vt8OIwnEzGqwMO2FsZam5PPbMMt87t8M9cblyprxgwDKl_swG4YBD4tqrVK0hZtiSYae9vrZShYx9nijfL9X4NTctzoHP7vi0dQ_ynAI6MttBxDxWY10I9kVfaS1SQnAnqoogUZDd6Iuz4vkm_E4ZIhuCjQisxyq3XpO4IOKlnN8LCQj2VqyN3r8z1JZ98Mcre7DuPO07jd9coZCV4qWmsviGjiWxS3wb-a5YEwPNDGGh4FxuhQq0hTDLlMLANJZWJbKpIsZDoKExpLdC1OoJrNM3sKRHChOII7My7EUFxyKl17MXTwmImEPoOak890UXTBmJaiOf_78Q3sd8eD_rTfG75cwIFTR0ECuYTqermxV7CnP9fpanmdK_ELgk2f3w |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2017+IEEE+Transportation+Electrification+Conference+%28ITEC-India%29&rft.atitle=A+strategic+multi-step+PMU+allocation+based+on+direct+monitoring+for+smart+grid+%28SG%29+implementation&rft.au=Maji%2C+Tapas+Kumar&rft.au=Acharjee%2C+P.&rft.date=2017-12-01&rft.pub=IEEE&rft.spage=1&rft.epage=6&rft_id=info:doi/10.1109%2FITEC-India.2017.8333829&rft.externalDocID=8333829 |