FPGA-based embedded system implementation of finger vein biometrics
With the ubiquitous deployment and rapid growth of electronic information systems in today's society, personal or identity verification is now a critical key problem. Due to this fact, biometric authentication has emergently gaining popularity as it provides a high security and reliable approac...
Uložené v:
| Vydané v: | 2010 IEEE Symposium on Industrial Electronics and Applications s. 700 - 705 |
|---|---|
| Hlavní autori: | , |
| Médium: | Konferenčný príspevok.. |
| Jazyk: | English |
| Vydavateľské údaje: |
IEEE
01.10.2010
|
| Predmet: | |
| ISBN: | 1424476453, 9781424476459 |
| On-line prístup: | Získať plný text |
| Tagy: |
Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
|
| Abstract | With the ubiquitous deployment and rapid growth of electronic information systems in today's society, personal or identity verification is now a critical key problem. Due to this fact, biometric authentication has emergently gaining popularity as it provides a high security and reliable approach for personal authentication. However, authentication using ones biometric features has not been widely implemented in a real time embedded system. Thus, in this paper, a novel approach to personal verification using infrared finger vein biometric authentication implemented on FPGA-based embedded system is presented. Creating a biometric authentication system in this resource-constrained embedded system for a real-time application, being a challenging problem in itself, is a significant contribution of this work. The proposed biometric system consists of four modules, namely image acquisition, image pre-processing, feature extraction, and matching. Feature extraction is based on minutiae extracted from the vein pattern image, while the biometric matching utilizes a technique based on the Modified Hausdorff Distance. The system is prototyped on Altera Stratix II FPGA hardware board with Nios2-Linux Real Time Operating System running at 100 MHz clock rate. Experiments conducted on a database of 100 images from 20 different hands shows encouraging results with system acceptable accuracy of less than 1.004%. Our first version of the embedded system, which is wholly in firmware, resulted in an execution time of 1953×10 6 clock cycles or 19 seconds. The results demonstrate that our approach is valid and effective for vein-pattern biometric authentication. |
|---|---|
| AbstractList | With the ubiquitous deployment and rapid growth of electronic information systems in today's society, personal or identity verification is now a critical key problem. Due to this fact, biometric authentication has emergently gaining popularity as it provides a high security and reliable approach for personal authentication. However, authentication using ones biometric features has not been widely implemented in a real time embedded system. Thus, in this paper, a novel approach to personal verification using infrared finger vein biometric authentication implemented on FPGA-based embedded system is presented. Creating a biometric authentication system in this resource-constrained embedded system for a real-time application, being a challenging problem in itself, is a significant contribution of this work. The proposed biometric system consists of four modules, namely image acquisition, image pre-processing, feature extraction, and matching. Feature extraction is based on minutiae extracted from the vein pattern image, while the biometric matching utilizes a technique based on the Modified Hausdorff Distance. The system is prototyped on Altera Stratix II FPGA hardware board with Nios2-Linux Real Time Operating System running at 100 MHz clock rate. Experiments conducted on a database of 100 images from 20 different hands shows encouraging results with system acceptable accuracy of less than 1.004%. Our first version of the embedded system, which is wholly in firmware, resulted in an execution time of 1953×10 6 clock cycles or 19 seconds. The results demonstrate that our approach is valid and effective for vein-pattern biometric authentication. |
| Author | Eng, P C Khalil-Hani, M |
| Author_xml | – sequence: 1 givenname: M surname: Khalil-Hani fullname: Khalil-Hani, M email: khalil@fke.utm.my organization: Fac. of Electr. Eng., Univ. Teknol. Malaysia, Skudai, Malaysia – sequence: 2 givenname: P C surname: Eng fullname: Eng, P C email: peichee84@hotmail.com organization: Fac. of Electr. Eng., Univ. Teknol. Malaysia, Skudai, Malaysia |
| BookMark | eNpFj8tKAzEYhSMqaGtfQDd5gam5TJLJchjaOlBQsPuSyz8SaTJlEoS-vQMWPJvvfJsDZ4Hu0pgAoWdK1pQS_dp_9pt2zcjsQirNlbxBC1qzulaylvT2XwR_QKucv8kcwVRNyCPqth-7trImg8cQLXg_l3zJBSIO8XyCCKmYEsaExwEPIX3BhH8gJGzDGKFMweUndD-YU4bVlUt02G4O3Vu1f9_1XbuvgialYtA0jlsrJXXaOaYc0ZrrQVAnOVOGKU8FWBDEAjUAjTdaMdJYOzDLveFL9PI3GwDgeJ5CNNPleP3MfwHz1U1F |
| ContentType | Conference Proceeding |
| DBID | 6IE 6IL CBEJK RIE RIL |
| DOI | 10.1109/ISIEA.2010.5679376 |
| DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present |
| DatabaseTitleList | |
| Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://ieeexplore.ieee.org/ sourceTypes: Publisher |
| DeliveryMethod | fulltext_linktorsrc |
| EISBN | 1424476461 9781424476473 9781424476466 142447647X |
| EndPage | 705 |
| ExternalDocumentID | 5679376 |
| Genre | orig-research |
| GroupedDBID | 6IE 6IF 6IK 6IL 6IN AAJGR AAWTH ADFMO ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK IEGSK IERZE OCL RIE RIL |
| ID | FETCH-LOGICAL-i90t-2e88c3bb661c9cc27c09939f51c6327a27d15ebe50be1aee8da97208bbf2b3da3 |
| IEDL.DBID | RIE |
| ISBN | 1424476453 9781424476459 |
| IngestDate | Wed Aug 27 03:05:48 EDT 2025 |
| IsPeerReviewed | false |
| IsScholarly | false |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-i90t-2e88c3bb661c9cc27c09939f51c6327a27d15ebe50be1aee8da97208bbf2b3da3 |
| PageCount | 6 |
| ParticipantIDs | ieee_primary_5679376 |
| PublicationCentury | 2000 |
| PublicationDate | 2010-Oct. |
| PublicationDateYYYYMMDD | 2010-10-01 |
| PublicationDate_xml | – month: 10 year: 2010 text: 2010-Oct. |
| PublicationDecade | 2010 |
| PublicationTitle | 2010 IEEE Symposium on Industrial Electronics and Applications |
| PublicationTitleAbbrev | ISIEA |
| PublicationYear | 2010 |
| Publisher | IEEE |
| Publisher_xml | – name: IEEE |
| SSID | ssj0000527400 |
| Score | 1.5366753 |
| Snippet | With the ubiquitous deployment and rapid growth of electronic information systems in today's society, personal or identity verification is now a critical key... |
| SourceID | ieee |
| SourceType | Publisher |
| StartPage | 700 |
| SubjectTerms | Authentication Biometric Biometrics Embedded System Feature extraction Finger Vein Fingers FPGA Gray-scale Pixel RTOS Veins |
| Title | FPGA-based embedded system implementation of finger vein biometrics |
| URI | https://ieeexplore.ieee.org/document/5679376 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LawMhEJYk9NBTW5LSNx567DaurroeQ0jaQAmBhpJbUHcW9pBNyev3R93dlEIvvakHUQbn5XzfIPRMtBbWijjiEnTk6U8io50ypDpRTlMKkCHf8fUhp9N0sVCzFno5YWEAIBSfwasfhr_8bG33PlXW58KzuYk2akspKqzWKZ9CuIuvCGmwW1IknDWUTvVcNaAZovqTz8loUFV21bv-aq8SrMv44n_nukS9H5genp0M0BVqQdlFw_HsbRB545RhWBlwiiXDFV8zLlZNtbgXB17nOA9ZPXyAosQBie8J-7c9NB-P5sP3qO6UEBWK7CIKaWqZMc7WWmUtldb5fUzlPLaCUampzGLupMWJgVgDpJlWkpLUmJwalml2jTrluoQbhJNESxZnJiW5Spx3Y9yDj10gaxMClBh-i7r-_svvigtjWV_97u_le3QefttD8dsD6uw2e3hEZ_awK7abpyDAI-hzl5U |
| linkProvider | IEEE |
| linkToHtml | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LSwMxEB5qFfSk0opvc_Do2mx2s9kcS2ltsZaCRXorSXYWenArff1-k3S3InjxluQQMgyZSWbm-wbgkSqVGJOEAReoAkd_EmhljSFTsbSWMkHh4x0fQzEapdOpHNfgaY-FQURffIbPbuhz-dnCbFyorMUTx-aWHMCh65xVorX2ERXK7Q-L0gq9JZKYRxWpUzmXFWyGytbgfdBt72q7yn1_NVjx_qV3-r-TnUHzB6hHxnsXdA41LBrQ6Y1f2oFzTxnBT43WtGRkx9hM5p9VvbhTCFnkJPdxPbLFeUE8Ft9R9q-aMOl1J51-UPZKCOaSrgOGaWoira23NdIYJox9-UUy56FJIiYUE1nIrb441RgqxDRTUjCaap0zHWUquoB6sSjwEkgcKxGFmU5pLmP7vtH2yof2K2tiioxqfgUNJ__sa8eGMStFv_57-QGO-5O34Ww4GL3ewInPvftSuFuor5cbvIMjs13PV8t7r8xvBKKa3g |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2010+IEEE+Symposium+on+Industrial+Electronics+and+Applications&rft.atitle=FPGA-based+embedded+system+implementation+of+finger+vein+biometrics&rft.au=Khalil-Hani%2C+M&rft.au=Eng%2C+P+C&rft.date=2010-10-01&rft.pub=IEEE&rft.isbn=9781424476459&rft.spage=700&rft.epage=705&rft_id=info:doi/10.1109%2FISIEA.2010.5679376&rft.externalDocID=5679376 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424476459/lc.gif&client=summon&freeimage=true |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424476459/mc.gif&client=summon&freeimage=true |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424476459/sc.gif&client=summon&freeimage=true |

