A Multifunctional Reduced Sensor Control for Grid-Interfaced Dual VSC Based Doubly Fed Induction Generator

This paper deals with reduced sensor based control algorithm for grid-interfaced doubly fed induction generator (DFIG), exhibiting twin functionalities of wind generation along with power quality enhancement capabilities. The grid side converter (GSC) control is modified to supply harmonics currents...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE Energy Conversion Congress and Exposition S. 6699 - 6705
Hauptverfasser: Das, Souvik, Puchalapalli, Sambasivaiah, Singh, Bhim
Format: Tagungsbericht
Sprache:Englisch
Veröffentlicht: IEEE 01.09.2019
Schlagworte:
ISSN:2329-3748
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Abstract This paper deals with reduced sensor based control algorithm for grid-interfaced doubly fed induction generator (DFIG), exhibiting twin functionalities of wind generation along with power quality enhancement capabilities. The grid side converter (GSC) control is modified to supply harmonics currents caused by nonlinear loads prevalent in the power network. Additionally, it helps in supplying load reactive power and maintaining unity power factor at the supply side. The GSC and rotor side converter control (RSC) are based on a stator current estimation scheme that requires a single current sensor as opposed to two in conventional control algorithm. A generalized integrator based stator flux estimation is used in reduced current sensor algorithm to avoid any possible DC offset and distortion in the estimated flux. An experimental prototype is developed to validate the proposed system.
AbstractList This paper deals with reduced sensor based control algorithm for grid-interfaced doubly fed induction generator (DFIG), exhibiting twin functionalities of wind generation along with power quality enhancement capabilities. The grid side converter (GSC) control is modified to supply harmonics currents caused by nonlinear loads prevalent in the power network. Additionally, it helps in supplying load reactive power and maintaining unity power factor at the supply side. The GSC and rotor side converter control (RSC) are based on a stator current estimation scheme that requires a single current sensor as opposed to two in conventional control algorithm. A generalized integrator based stator flux estimation is used in reduced current sensor algorithm to avoid any possible DC offset and distortion in the estimated flux. An experimental prototype is developed to validate the proposed system.
Author Puchalapalli, Sambasivaiah
Das, Souvik
Singh, Bhim
Author_xml – sequence: 1
  givenname: Souvik
  surname: Das
  fullname: Das, Souvik
  organization: Indian Institute of Technology,Department of Electrical Engineering,New Delhi,India,110016
– sequence: 2
  givenname: Sambasivaiah
  surname: Puchalapalli
  fullname: Puchalapalli, Sambasivaiah
  organization: Indian Institute of Technology,Department of Electrical Engineering,New Delhi,India,110016
– sequence: 3
  givenname: Bhim
  surname: Singh
  fullname: Singh, Bhim
  organization: Indian Institute of Technology,Department of Electrical Engineering,New Delhi,India,110016
BookMark eNotkEtOwzAYhA0Cibb0AIiNL5DgRxzbyxLSEqkIiQLbyk5-S6mCjZxk0duTiK5mRjP6FrNENz54QOiBkpRSop_KoihTRqhOlaZMCH2FllQyRQnXQl-jBeNMJ1xm6g6t-_5ECKG5YorQBTpt8NvYDa0bfT20wZsOf0Az1tDgA_g-RFwEP8TQYTf5XWybpPIDRGfmycs47b8PBX42_RzDaLsz3k628hNkBuIdeIhmCPEe3TrT9bC-6Ap9bcvP4jXZv--qYrNPWkb4kBjJuRVKaVnnznHQnGXWWZCgmJlKASSvqcwBsswKQ7QAJyXYppHK5bbhK_T4z20B4Pgb2x8Tz8fLNfwPzNNacg
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/ECCE.2019.8912559
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISBN 1728103959
9781728103952
EISSN 2329-3748
EndPage 6705
ExternalDocumentID 8912559
Genre orig-research
GroupedDBID 6IE
6IF
6IH
6IK
6IL
6IN
AAJGR
AAWTH
ABLEC
ACGFS
ADZIZ
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
CHZPO
IEGSK
IPLJI
M43
OCL
RIE
RIL
ID FETCH-LOGICAL-i203t-a733b58897c6ff3e9324bfbe7e82aa735e06c176ee44b5a095ef77ebdd78f6bd3
IEDL.DBID RIE
ISICitedReferencesCount 1
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000520543707014&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
IngestDate Wed Aug 27 02:50:37 EDT 2025
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i203t-a733b58897c6ff3e9324bfbe7e82aa735e06c176ee44b5a095ef77ebdd78f6bd3
PageCount 7
ParticipantIDs ieee_primary_8912559
PublicationCentury 2000
PublicationDate 2019-Sept.
PublicationDateYYYYMMDD 2019-09-01
PublicationDate_xml – month: 09
  year: 2019
  text: 2019-Sept.
PublicationDecade 2010
PublicationTitle IEEE Energy Conversion Congress and Exposition
PublicationTitleAbbrev ECCE
PublicationYear 2019
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0001682801
Score 1.7050782
Snippet This paper deals with reduced sensor based control algorithm for grid-interfaced doubly fed induction generator (DFIG), exhibiting twin functionalities of wind...
SourceID ieee
SourceType Publisher
StartPage 6699
SubjectTerms Doubly fed induction generator
Doubly fed induction generators
Harmonic analysis
Power harmonic filters
power quality
Radio frequency
Reactive power
reduced sensor
Rotors
stator field oriented vector control
Stators
Title A Multifunctional Reduced Sensor Control for Grid-Interfaced Dual VSC Based Doubly Fed Induction Generator
URI https://ieeexplore.ieee.org/document/8912559
WOSCitedRecordID wos000520543707014&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV07T8MwED61FQMsPFrEWx4YCU3qxHZGCC0MqKoooG6VHxepqGpQaJD499hO1YLEwuYkdiz5bN1357vvAC7TKE3R2IOEXKkgjngUyF6iAmn3kzSaxYn2JK6PfDgUk0k6asDVOhcGEX3wGV67pr_LN4WunKusK9LIIeAmNDlnda7Wxp_CrO0QRquLyyhMu_0s67vYLbsZ6nG_Cqh4_THY_d_Me9DZJOKR0VrF7EMDFwew84NDsA1vN8Qn0ToFVfv1yJOjY0VDxtZELUqS1dHoxMJTcl_OTOC9gLl0Xe4q2_91nJFbq83sY1Gp-RcZ2Kar6eF_SGpmamubd-Bl0H_OHoJVAYVg1gvpMpCcUpUIkXLN8pyixWqxyhVyFD1pPyYYMh1xhhjHKpEWbWHOOSpjuMiZMvQQWotigUdApA4Fjw11CCPm1MrRJMhCKWmuBQp-DG23atP3miNjulqwk79fn8K2E0wdq3UGrWVZ4Tls6c_l7KO88IL9Bogrpdc
linkProvider IEEE
linkToHtml http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV3dS8MwEA9zCuqLH1P8Ng8-Wtc2aZM-at2cOMdwU_Y28nGFiaxSV8H_3iQdm4IvvqVt0kAu4X53ufsdQhdJkCSgzUECJqVHAxZ4IoykJ8x-ElrFNFKOxLXLej0-GiX9Grpc5MIAgAs-gyvbdHf5OleldZU1eRJYBLyCViNKQ7_K1lp6VGJjPfjB_Ooy8JNmK01bNnrLbIdq5K8SKk6DtLf-N_c22lum4uH-QsnsoBpMd9HmDxbBBnq9xi6N1qqoyrOHnywhK2g8MEZqXuC0ikfHBqDiu2KiPecHzITtclua_i-DFN8YfWYe81K-feG2adqqHu6HuOKmNtb5Hnput4Zpx5uXUPAmoU9mnmCEyIjzhKk4ywgYtEZlJoEBD4X5GIEfq4DFAJTKSBi8BRljILVmPIulJvuoPs2ncICwUD5nVBOLMSgjRpI6gtgXgmSKA2eHqGFXbfxesWSM5wt29Pfrc7TeGT52x9373sMx2rBCqiK3TlB9VpRwitbU52zyUZw5IX8DVHepHg
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=proceeding&rft.title=IEEE+Energy+Conversion+Congress+and+Exposition&rft.atitle=A+Multifunctional+Reduced+Sensor+Control+for+Grid-Interfaced+Dual+VSC+Based+Doubly+Fed+Induction+Generator&rft.au=Das%2C+Souvik&rft.au=Puchalapalli%2C+Sambasivaiah&rft.au=Singh%2C+Bhim&rft.date=2019-09-01&rft.pub=IEEE&rft.eissn=2329-3748&rft.spage=6699&rft.epage=6705&rft_id=info:doi/10.1109%2FECCE.2019.8912559&rft.externalDocID=8912559