DC State Estimation Model-Based Mixed Integer Semidefinite Programming for Optimal PMU Placement

Phasor measurement units (PMUs) can make state estimation more accurate by providing synchronized voltage phasor and current phasor measurements. Optimal PMU placement (OPP) minimizes the number of PMUs required for the system to be completely observable. This paper presents a DC state estimation mo...

Celý popis

Uložené v:
Podrobná bibliografia
Vydané v:NAPS : 2018 North American Power Symposium : 9-11 September 2018, Fargo, ND, USA s. 1 - 6
Hlavní autori: Almunif, Anas, Fan, Lingling
Médium: Konferenčný príspevok..
Jazyk:English
Vydavateľské údaje: IEEE 01.09.2018
Predmet:
On-line prístup:Získať plný text
Tagy: Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
Abstract Phasor measurement units (PMUs) can make state estimation more accurate by providing synchronized voltage phasor and current phasor measurements. Optimal PMU placement (OPP) minimizes the number of PMUs required for the system to be completely observable. This paper presents a DC state estimation model using mixed integer semidefinite programming (MISDP) approach for the OPP problem. A comparison between MISDP and mixed integer linear programming (MILP) is conducted. Power flow measurements, injection measurements, limited communication facility, and single PMU failure are studied for each approach. A formulation for MISDP-based PMU placement considering a single PMU failure is proposed. The advantages and disadvantages of each formulation are discussed.
AbstractList Phasor measurement units (PMUs) can make state estimation more accurate by providing synchronized voltage phasor and current phasor measurements. Optimal PMU placement (OPP) minimizes the number of PMUs required for the system to be completely observable. This paper presents a DC state estimation model using mixed integer semidefinite programming (MISDP) approach for the OPP problem. A comparison between MISDP and mixed integer linear programming (MILP) is conducted. Power flow measurements, injection measurements, limited communication facility, and single PMU failure are studied for each approach. A formulation for MISDP-based PMU placement considering a single PMU failure is proposed. The advantages and disadvantages of each formulation are discussed.
Author Almunif, Anas
Fan, Lingling
Author_xml – sequence: 1
  givenname: Anas
  surname: Almunif
  fullname: Almunif, Anas
  organization: Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA
– sequence: 2
  givenname: Lingling
  surname: Fan
  fullname: Fan, Lingling
  organization: Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA
BookMark eNotkM1OwzAQhI0EElD6AIiLXyBlnR__HEspUKmlkUrPxY7XlVHiVIkP8PYY0cusdlb7aTS35DL0AQm5ZzBjDNTj-7zezXJgciY5QCXkBZkqIVlVSC5YIfNrMh3HLwDIuSyTfUM-nxd0F3VEuhyj73T0faCb3mKbPekRLd3476SrEPGIA91h5y06H3z6qIf-OOiu8-FIXT_Q7emP0NJ6s6d1qxvsMMQ7cuV0O-L0PCdk_7L8WLxl6-3rajFfZ56JKmaKl8YAplQMpQbDKsEdQGN5rqVSIK0tS2N15QphhFOFSWfepL0yrlGymJCHf65HxMNpSEmGn8O5h-IXVUpVXw
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/NAPS.2018.8600578
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISBN 9781538671382
1538671387
EndPage 6
ExternalDocumentID 8600578
Genre orig-research
GroupedDBID 6IE
6IF
6IL
6IN
AAJGR
AAWTH
ABLEC
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
IEGSK
OCL
RIE
RIL
ID FETCH-LOGICAL-i175t-964bb0e8411e8a0b1576f00cd62a89908dd44bda5f37b7f93b6f06ca5f5bfc983
IEDL.DBID RIE
ISICitedReferencesCount 1
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000458721400040&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
IngestDate Wed Aug 27 02:58:26 EDT 2025
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i175t-964bb0e8411e8a0b1576f00cd62a89908dd44bda5f37b7f93b6f06ca5f5bfc983
PageCount 6
ParticipantIDs ieee_primary_8600578
PublicationCentury 2000
PublicationDate 2018-Sept.
PublicationDateYYYYMMDD 2018-09-01
PublicationDate_xml – month: 09
  year: 2018
  text: 2018-Sept.
PublicationDecade 2010
PublicationTitle NAPS : 2018 North American Power Symposium : 9-11 September 2018, Fargo, ND, USA
PublicationTitleAbbrev NAPS
PublicationYear 2018
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0002684153
Score 1.6842167
Snippet Phasor measurement units (PMUs) can make state estimation more accurate by providing synchronized voltage phasor and current phasor measurements. Optimal PMU...
SourceID ieee
SourceType Publisher
StartPage 1
SubjectTerms Current measurement
Mixed integer linear programming
mixed integer semidefinite programming
Observability
optimal PMU placement
Phasor measurement units
Power measurement
Programming
State estimation
Voltage measurement
Title DC State Estimation Model-Based Mixed Integer Semidefinite Programming for Optimal PMU Placement
URI https://ieeexplore.ieee.org/document/8600578
WOSCitedRecordID wos000458721400040&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV07T8MwELbaigEWHi3iLQ-MuE0aJ3ZGKK1YWiKVSt1K_EKR-lJoET-fuyQqILGwRE4sn6OzTvfwfXeE3PpapMZFjnEtAsbjrmNSBYppsMV11wQ64K5oNiFGIzmdxkmN3O2wMNbaIvnMtnFY3OWbld5iqKwjI8ROyjqpCxGVWK1dPAWrloD0VheXvhd3RvfJGHO3ZLta96uBSqE_Bof_2_mItL6BeDTZqZhjUrPLE3Lwo4Zgk7w-9mhhMdI-SGsJRKTY4WzOHkBDGTrMPuGJkb83m9OxXWTGugxNTSSNyVkLIETBeKXPa6Qwp8lwQhOMr-Nftchk0H_pPbGqbQLLwBbYsDjiSnkW2OFbmXrKB5fCeZ42UTcF78qTxnCuTBq6QCjh4kDBdKThPVROxzI4JY3lamnPCIXFIgIJNtKE3CGGN4x5akMFTp500j8nTeTVbF1WxphVbLr4-_Ml2cfjKDO0rkhjk2_tNdnTH5vsPb8pjvML4WShsQ
linkProvider IEEE
linkToHtml http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LT8JAEN4gmqgXH2B8uwePLrR0226PihCMgE2AhBt2X6YJryAYf74zpUFNvHhptt3sbDObyTx2vhlCbl0VJtoGlnEVeoxHNcuE9CRTYIurmvaUx23WbCLsdsVwGMUFcrfBwhhjsuQzU8FhdpevZ2qFobKqCBA7KbbINnbOytFam4gK1i0B-c2vLl0nqnbv4x5mb4lKvvJXC5VMgzQP_rf3ISl_Q_FovFEyR6Rgpsdk_0cVwRJ5fazTzGakDZDXNRSRYo-zMXsAHaVpJ_2EJ8b-3syC9swk1camaGwiaUzPmgAhCuYrfZkjhTGNOwMaY4Qd_6pMBs1Gv95ieeMEloI1sGRRwKV0DLDDNSJxpAtOhXUcpYNaAv6VI7TmXOrEt14oQxt5EqYDBe--tCoS3gkpTmdTc0ooLA4DkGEttM8tonj9iCfGl-DmCSvcM1JCXo3m69oYo5xN539_viG7rX6nPWo_dZ8vyB4ezTpf65IUl4uVuSI76mOZvi-us6P9AnzjpPo
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=NAPS+%3A+2018+North+American+Power+Symposium+%3A+9-11+September+2018%2C+Fargo%2C+ND%2C+USA&rft.atitle=DC+State+Estimation+Model-Based+Mixed+Integer+Semidefinite+Programming+for+Optimal+PMU+Placement&rft.au=Almunif%2C+Anas&rft.au=Fan%2C+Lingling&rft.date=2018-09-01&rft.pub=IEEE&rft.spage=1&rft.epage=6&rft_id=info:doi/10.1109%2FNAPS.2018.8600578&rft.externalDocID=8600578