DC State Estimation Model-Based Mixed Integer Semidefinite Programming for Optimal PMU Placement
Phasor measurement units (PMUs) can make state estimation more accurate by providing synchronized voltage phasor and current phasor measurements. Optimal PMU placement (OPP) minimizes the number of PMUs required for the system to be completely observable. This paper presents a DC state estimation mo...
Uložené v:
| Vydané v: | NAPS : 2018 North American Power Symposium : 9-11 September 2018, Fargo, ND, USA s. 1 - 6 |
|---|---|
| Hlavní autori: | , |
| Médium: | Konferenčný príspevok.. |
| Jazyk: | English |
| Vydavateľské údaje: |
IEEE
01.09.2018
|
| Predmet: | |
| On-line prístup: | Získať plný text |
| Tagy: |
Pridať tag
Žiadne tagy, Buďte prvý, kto otaguje tento záznam!
|
| Abstract | Phasor measurement units (PMUs) can make state estimation more accurate by providing synchronized voltage phasor and current phasor measurements. Optimal PMU placement (OPP) minimizes the number of PMUs required for the system to be completely observable. This paper presents a DC state estimation model using mixed integer semidefinite programming (MISDP) approach for the OPP problem. A comparison between MISDP and mixed integer linear programming (MILP) is conducted. Power flow measurements, injection measurements, limited communication facility, and single PMU failure are studied for each approach. A formulation for MISDP-based PMU placement considering a single PMU failure is proposed. The advantages and disadvantages of each formulation are discussed. |
|---|---|
| AbstractList | Phasor measurement units (PMUs) can make state estimation more accurate by providing synchronized voltage phasor and current phasor measurements. Optimal PMU placement (OPP) minimizes the number of PMUs required for the system to be completely observable. This paper presents a DC state estimation model using mixed integer semidefinite programming (MISDP) approach for the OPP problem. A comparison between MISDP and mixed integer linear programming (MILP) is conducted. Power flow measurements, injection measurements, limited communication facility, and single PMU failure are studied for each approach. A formulation for MISDP-based PMU placement considering a single PMU failure is proposed. The advantages and disadvantages of each formulation are discussed. |
| Author | Almunif, Anas Fan, Lingling |
| Author_xml | – sequence: 1 givenname: Anas surname: Almunif fullname: Almunif, Anas organization: Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA – sequence: 2 givenname: Lingling surname: Fan fullname: Fan, Lingling organization: Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, USA |
| BookMark | eNotkM1OwzAQhI0EElD6AIiLXyBlnR__HEspUKmlkUrPxY7XlVHiVIkP8PYY0cusdlb7aTS35DL0AQm5ZzBjDNTj-7zezXJgciY5QCXkBZkqIVlVSC5YIfNrMh3HLwDIuSyTfUM-nxd0F3VEuhyj73T0faCb3mKbPekRLd3476SrEPGIA91h5y06H3z6qIf-OOiu8-FIXT_Q7emP0NJ6s6d1qxvsMMQ7cuV0O-L0PCdk_7L8WLxl6-3rajFfZ56JKmaKl8YAplQMpQbDKsEdQGN5rqVSIK0tS2N15QphhFOFSWfepL0yrlGymJCHf65HxMNpSEmGn8O5h-IXVUpVXw |
| ContentType | Conference Proceeding |
| DBID | 6IE 6IL CBEJK RIE RIL |
| DOI | 10.1109/NAPS.2018.8600578 |
| DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present |
| DatabaseTitleList | |
| Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://ieeexplore.ieee.org/ sourceTypes: Publisher |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Engineering |
| EISBN | 9781538671382 1538671387 |
| EndPage | 6 |
| ExternalDocumentID | 8600578 |
| Genre | orig-research |
| GroupedDBID | 6IE 6IF 6IL 6IN AAJGR AAWTH ABLEC ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK IEGSK OCL RIE RIL |
| ID | FETCH-LOGICAL-i175t-964bb0e8411e8a0b1576f00cd62a89908dd44bda5f37b7f93b6f06ca5f5bfc983 |
| IEDL.DBID | RIE |
| ISICitedReferencesCount | 1 |
| ISICitedReferencesURI | http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000458721400040&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| IngestDate | Wed Aug 27 02:58:26 EDT 2025 |
| IsPeerReviewed | false |
| IsScholarly | false |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-i175t-964bb0e8411e8a0b1576f00cd62a89908dd44bda5f37b7f93b6f06ca5f5bfc983 |
| PageCount | 6 |
| ParticipantIDs | ieee_primary_8600578 |
| PublicationCentury | 2000 |
| PublicationDate | 2018-Sept. |
| PublicationDateYYYYMMDD | 2018-09-01 |
| PublicationDate_xml | – month: 09 year: 2018 text: 2018-Sept. |
| PublicationDecade | 2010 |
| PublicationTitle | NAPS : 2018 North American Power Symposium : 9-11 September 2018, Fargo, ND, USA |
| PublicationTitleAbbrev | NAPS |
| PublicationYear | 2018 |
| Publisher | IEEE |
| Publisher_xml | – name: IEEE |
| SSID | ssj0002684153 |
| Score | 1.6842167 |
| Snippet | Phasor measurement units (PMUs) can make state estimation more accurate by providing synchronized voltage phasor and current phasor measurements. Optimal PMU... |
| SourceID | ieee |
| SourceType | Publisher |
| StartPage | 1 |
| SubjectTerms | Current measurement Mixed integer linear programming mixed integer semidefinite programming Observability optimal PMU placement Phasor measurement units Power measurement Programming State estimation Voltage measurement |
| Title | DC State Estimation Model-Based Mixed Integer Semidefinite Programming for Optimal PMU Placement |
| URI | https://ieeexplore.ieee.org/document/8600578 |
| WOSCitedRecordID | wos000458721400040&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV07T8MwELbaigEWHi3iLQ-MuE0aJ3ZGKK1YWiKVSt1K_EKR-lJoET-fuyQqILGwRE4sn6OzTvfwfXeE3PpapMZFjnEtAsbjrmNSBYppsMV11wQ64K5oNiFGIzmdxkmN3O2wMNbaIvnMtnFY3OWbld5iqKwjI8ROyjqpCxGVWK1dPAWrloD0VheXvhd3RvfJGHO3ZLta96uBSqE_Bof_2_mItL6BeDTZqZhjUrPLE3Lwo4Zgk7w-9mhhMdI-SGsJRKTY4WzOHkBDGTrMPuGJkb83m9OxXWTGugxNTSSNyVkLIETBeKXPa6Qwp8lwQhOMr-Nftchk0H_pPbGqbQLLwBbYsDjiSnkW2OFbmXrKB5fCeZ42UTcF78qTxnCuTBq6QCjh4kDBdKThPVROxzI4JY3lamnPCIXFIgIJNtKE3CGGN4x5akMFTp500j8nTeTVbF1WxphVbLr4-_Ml2cfjKDO0rkhjk2_tNdnTH5vsPb8pjvML4WShsQ |
| linkProvider | IEEE |
| linkToHtml | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LT8JAEN4gmqgXH2B8uwePLrR0226PihCMgE2AhBt2X6YJryAYf74zpUFNvHhptt3sbDObyTx2vhlCbl0VJtoGlnEVeoxHNcuE9CRTYIurmvaUx23WbCLsdsVwGMUFcrfBwhhjsuQzU8FhdpevZ2qFobKqCBA7KbbINnbOytFam4gK1i0B-c2vLl0nqnbv4x5mb4lKvvJXC5VMgzQP_rf3ISl_Q_FovFEyR6Rgpsdk_0cVwRJ5fazTzGakDZDXNRSRYo-zMXsAHaVpJ_2EJ8b-3syC9swk1camaGwiaUzPmgAhCuYrfZkjhTGNOwMaY4Qd_6pMBs1Gv95ieeMEloI1sGRRwKV0DLDDNSJxpAtOhXUcpYNaAv6VI7TmXOrEt14oQxt5EqYDBe--tCoS3gkpTmdTc0ooLA4DkGEttM8tonj9iCfGl-DmCSvcM1JCXo3m69oYo5xN539_viG7rX6nPWo_dZ8vyB4ezTpf65IUl4uVuSI76mOZvi-us6P9AnzjpPo |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=NAPS+%3A+2018+North+American+Power+Symposium+%3A+9-11+September+2018%2C+Fargo%2C+ND%2C+USA&rft.atitle=DC+State+Estimation+Model-Based+Mixed+Integer+Semidefinite+Programming+for+Optimal+PMU+Placement&rft.au=Almunif%2C+Anas&rft.au=Fan%2C+Lingling&rft.date=2018-09-01&rft.pub=IEEE&rft.spage=1&rft.epage=6&rft_id=info:doi/10.1109%2FNAPS.2018.8600578&rft.externalDocID=8600578 |