Application of GA for three-area power system after deregulation with valve position limit

In recent years, electric power industry has been moving towards a deregulated framework all over the world. Many problems have appeared in the new situation. The valve position limit exhibits nonlinear character in the deregulated environment. In this work, distribute companies participation matrix...

Full description

Saved in:
Bibliographic Details
Published in:2012 24th Chinese Control and Decision Conference (CCDC) pp. 1018 - 1022
Main Authors: Guolian Hou, Xinyan Zheng, Lina Qin, Jianhua Zhang
Format: Conference Proceeding
Language:English
Published: IEEE 01.05.2012
Subjects:
ISBN:9781457720734, 1457720736
ISSN:1948-9439
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract In recent years, electric power industry has been moving towards a deregulated framework all over the world. Many problems have appeared in the new situation. The valve position limit exhibits nonlinear character in the deregulated environment. In this work, distribute companies participation matrix (DPM) is brought in to analyze the effect of the DPM to the dynamic performance of the system. T-S model is proposed to construct valve position nonlinear constraint. Real-coded GA is used and the initial population is obtained by uniform sampling. It takes less time than the common algorithm. The simulation results of the three-area power system are then introduced to demonstrate the validity of the results.
AbstractList In recent years, electric power industry has been moving towards a deregulated framework all over the world. Many problems have appeared in the new situation. The valve position limit exhibits nonlinear character in the deregulated environment. In this work, distribute companies participation matrix (DPM) is brought in to analyze the effect of the DPM to the dynamic performance of the system. T-S model is proposed to construct valve position nonlinear constraint. Real-coded GA is used and the initial population is obtained by uniform sampling. It takes less time than the common algorithm. The simulation results of the three-area power system are then introduced to demonstrate the validity of the results.
Author Guolian Hou
Jianhua Zhang
Lina Qin
Xinyan Zheng
Author_xml – sequence: 1
  surname: Guolian Hou
  fullname: Guolian Hou
  email: hgl@ncepu.edu.cn
  organization: North China Electr. Power Univ., Beijing, China
– sequence: 2
  surname: Xinyan Zheng
  fullname: Xinyan Zheng
  organization: North China Electr. Power Univ., Beijing, China
– sequence: 3
  surname: Lina Qin
  fullname: Lina Qin
  organization: North China Electr. Power Univ., Beijing, China
– sequence: 4
  surname: Jianhua Zhang
  fullname: Jianhua Zhang
  organization: North China Electr. Power Univ., Beijing, China
BookMark eNo1kE9PAjEUxGvEREA-gPHSL7DY177tnyNZBU1IvOjFCynwKjULu-lWCN9eInia_CYzc5gB6-2aHTF2D2IMINxjVT1VYylAjrVEhNJdsQFgaYwURtprNnLG_rPCHuuDQ1s4VO6WDbruWwitlRB99jlp2zqufI7NjjeBzyY8NInnTSIqfCLP2-ZAiXfHLtOW-5BPsKZEXz_1uXSIecP3vt7TKdrFP6-O25jv2E3wdUejiw7Zx_T5vXop5m-z12oyLyKYMhfWOYl6rQAJzXpll8JqUAFA6xWEAM4CBBNEKIXTSNLZoDAErZZYEoJXQ_Zw3o1EtGhT3Pp0XFx-Ub-HJlZF
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/CCDC.2012.6244159
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISBN 1457720728
1457720744
9781457720741
9781457720727
EndPage 1022
ExternalDocumentID 6244159
Genre orig-research
GroupedDBID 29B
6IE
6IF
6IK
6IL
6IN
AAJGR
AAWTH
ABLEC
ADZIZ
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
CHZPO
IEGSK
IPLJI
M43
OCL
RIE
RIL
RNS
ID FETCH-LOGICAL-i175t-899246d314e47dc8b08613f1166c1ff19811f7f0f50964e298f34ff63b45e41a3
IEDL.DBID RIE
ISBN 9781457720734
1457720736
ISICitedReferencesCount 3
ISICitedReferencesURI http://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=Summon&SrcAuth=ProQuest&DestLinkType=CitingArticles&DestApp=WOS_CPL&KeyUT=000323966201011&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
ISSN 1948-9439
IngestDate Wed Aug 27 04:24:39 EDT 2025
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i175t-899246d314e47dc8b08613f1166c1ff19811f7f0f50964e298f34ff63b45e41a3
PageCount 5
ParticipantIDs ieee_primary_6244159
PublicationCentury 2000
PublicationDate 2012-May
PublicationDateYYYYMMDD 2012-05-01
PublicationDate_xml – month: 05
  year: 2012
  text: 2012-May
PublicationDecade 2010
PublicationTitle 2012 24th Chinese Control and Decision Conference (CCDC)
PublicationTitleAbbrev CCDC
PublicationYear 2012
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0066300
ssj0000781109
Score 1.5070391
Snippet In recent years, electric power industry has been moving towards a deregulated framework all over the world. Many problems have appeared in the new situation....
SourceID ieee
SourceType Publisher
StartPage 1018
SubjectTerms Automatic generation control
Contracts
DISCO Participation Matrix
Genetic algorithm
Genetic algorithms
Nonlinear unit
Optimization
Power system stability
Valves
Title Application of GA for three-area power system after deregulation with valve position limit
URI https://ieeexplore.ieee.org/document/6244159
WOSCitedRecordID wos000323966201011&url=https%3A%2F%2Fcvtisr.summon.serialssolutions.com%2F%23%21%2Fsearch%3Fho%3Df%26include.ft.matches%3Dt%26l%3Dnull%26q%3D
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1LT8JAEN4A8aAXH2B8Zw8eLbDb6bY9kip6MISDGuKFLN1ZQ2KAYOH3O7stoIkXb22TTZuZ3c43r28Yu5XCQGQUBF1LvglZfBMkRppAExbp0hIoyarfnuPBIBmN0mGN3W17YRDRF59h2136XL6Z5ysXKuso6dB_Wmf1OFZlr9Y2nuJIazxzePkXVo5KymeUgQ40WV3f1BURlqQ9rTZcT9U9VOlOWt_JsvvMVXzJdvW2X2NXvNXpH_7ve49Ya9e-x4dbw3TMajg7YQc_mAeb7L23S1zzueWPPU7olRekWQw0AUm-cOPTeEn0zP0kce7men5U4764C-By2qZr5JvCL_7puqVa7LX_8JI9BdWYhWBK2KEIyOOSoEwoACE2eTIhL0eEVgilcmGtSEmwNrZd65hiAGWa2BCsVeEEIgShw1PWmM1neMa4iPNYaq20jRRYpSciNZCj7uaJRIT0nDWdlMaLkkljXAno4u_Hl2zfKaIsL7xijWK5wmu2l6-L6dfyxqv_G653qRA
linkProvider IEEE
linkToHtml http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV3NT8IwFG8QTdSLH2D8tgePDtburduOBEWMSDigIV5IWVtDYoDg4O_3tRugiRdv25Jmy-vr3u99_R4ht5wpCJUAzzfom6DFV16suPIkYhEfl0BOVv3WibrdeDBIeiVyt-6F0Vq74jNds5cul6-m6cKGyuqCW_SfbJHtEID7ebfWOqJiaWscd3j-HxaWTMrllAGPNNpd19YVIppErRYrtqfiHoqEJ66vN5v3TVvzxWvF-34NXnF2p3Xwvy8-JNVNAx_trU3TESnpyTHZ_8E9WCHvjU3qmk4NfWxQxK80w73VnkQoSWd2gBrNqZ6pmyVO7WTPj2LgF7UhXIqKutR0VfpFP22_VJW8th76zbZXDFrwxogeMg99Lg5CBQw0RCqNR-jnsMAwJkTKjGEJCtZExjeWKwY0T2ITgDEiGEGogcnghJQn04k-JZRFacSlFNKEAoyQI5YoSLX005hrDckZqVgpDWc5l8awEND5349vyG67_9IZdp66zxdkz25KXmx4ScrZfKGvyE66zMZf82unCt-u7axX
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2012+24th+Chinese+Control+and+Decision+Conference+%28CCDC%29&rft.atitle=Application+of+GA+for+three-area+power+system+after+deregulation+with+valve+position+limit&rft.au=Guolian+Hou&rft.au=Xinyan+Zheng&rft.au=Lina+Qin&rft.au=Jianhua+Zhang&rft.date=2012-05-01&rft.pub=IEEE&rft.isbn=9781457720734&rft.issn=1948-9439&rft.spage=1018&rft.epage=1022&rft_id=info:doi/10.1109%2FCCDC.2012.6244159&rft.externalDocID=6244159
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1948-9439&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1948-9439&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1948-9439&client=summon