Short communication: use of the output video signal for dynamic range, brightness control and image memory assessment in X-ray fluoroscopy
The output video signal from three X-ray fluoroscopy machines was recorded with a storage oscilloscope to calculate the dynamic range of their image intensifier television camera chains. The two MERATE MTH90 and MGR50hf machines employed the same imaging chain but the response of the former to expos...
Saved in:
| Published in: | British journal of radiology Vol. 69; no. 825; p. 855 |
|---|---|
| Main Author: | |
| Format: | Journal Article |
| Language: | English |
| Published: |
England
01.09.1996
|
| Subjects: | |
| ISSN: | 0007-1285 |
| Online Access: | Get more information |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| Abstract | The output video signal from three X-ray fluoroscopy machines was recorded with a storage oscilloscope to calculate the dynamic range of their image intensifier television camera chains. The two MERATE MTH90 and MGR50hf machines employed the same imaging chain but the response of the former to exposure was significantly lower because of a three channel light distribution optical system which was installed but not used. The CGR Stenoscope machine was found to have a very narrow dynamic range to the extent that it was not usable. Additional measurements on the CGR machine showed that the image intensifier brightness control mechanism would produce stabilized brightness in less than 0.4 s and it proved to be faster than the manual selection of exposure parameters. The quality of the image stored in the memory device on the same system was compared with the original by subtracting the two video signals on the oscilloscope and thus acquiring a quantitative measure of their difference. |
|---|---|
| AbstractList | The output video signal from three X-ray fluoroscopy machines was recorded with a storage oscilloscope to calculate the dynamic range of their image intensifier television camera chains. The two MERATE MTH90 and MGR50hf machines employed the same imaging chain but the response of the former to exposure was significantly lower because of a three channel light distribution optical system which was installed but not used. The CGR Stenoscope machine was found to have a very narrow dynamic range to the extent that it was not usable. Additional measurements on the CGR machine showed that the image intensifier brightness control mechanism would produce stabilized brightness in less than 0.4 s and it proved to be faster than the manual selection of exposure parameters. The quality of the image stored in the memory device on the same system was compared with the original by subtracting the two video signals on the oscilloscope and thus acquiring a quantitative measure of their difference. The output video signal from three X-ray fluoroscopy machines was recorded with a storage oscilloscope to calculate the dynamic range of their image intensifier television camera chains. The two MERATE MTH90 and MGR50hf machines employed the same imaging chain but the response of the former to exposure was significantly lower because of a three channel light distribution optical system which was installed but not used. The CGR Stenoscope machine was found to have a very narrow dynamic range to the extent that it was not usable. Additional measurements on the CGR machine showed that the image intensifier brightness control mechanism would produce stabilized brightness in less than 0.4 s and it proved to be faster than the manual selection of exposure parameters. The quality of the image stored in the memory device on the same system was compared with the original by subtracting the two video signals on the oscilloscope and thus acquiring a quantitative measure of their difference.The output video signal from three X-ray fluoroscopy machines was recorded with a storage oscilloscope to calculate the dynamic range of their image intensifier television camera chains. The two MERATE MTH90 and MGR50hf machines employed the same imaging chain but the response of the former to exposure was significantly lower because of a three channel light distribution optical system which was installed but not used. The CGR Stenoscope machine was found to have a very narrow dynamic range to the extent that it was not usable. Additional measurements on the CGR machine showed that the image intensifier brightness control mechanism would produce stabilized brightness in less than 0.4 s and it proved to be faster than the manual selection of exposure parameters. The quality of the image stored in the memory device on the same system was compared with the original by subtracting the two video signals on the oscilloscope and thus acquiring a quantitative measure of their difference. |
| Author | Okkalides, D |
| Author_xml | – sequence: 1 givenname: D surname: Okkalides fullname: Okkalides, D organization: Radiation Physics Laboratory, IPPOKRATEIO General Hospital, Thessaloniki, Greece |
| BackLink | https://www.ncbi.nlm.nih.gov/pubmed/8983591$$D View this record in MEDLINE/PubMed |
| BookMark | eNo9UM1qGzEY1MHFsZ2-QQrfKaduq5WtlZRbMUlaMPSQBnIzWu2ntcpKciRtYV-hT50NNT0N88PAzJosQgxIyE1Nv9SMq6-UUlHVTPKqUZVkvJKcL8jqv3xF1jn_fqdc0SVZSiW3XNUr8vfpFFMBE70fgzO6uBjuYMwI0UI5zTCW81jgj-swQnZ90APYmKCbgvbOQNKhx8_QJtefSsCc565QUhxAhw6c1z2CRx_TBDrn2fcYCrgAL1XSE9hhjClmE8_TNflg9ZDx4wU35Pnh_tf-e3X4-fhj_-1Q9bUQpeLIUO6saLBtKeOGc1oj327bljXbnamp6jor68bsBCpKLdpGcyMME0J0TWvZhtz-6z2n-DpiLkfvssFh0AHjmI9CcqmE2s3BT5fg2Hrsjuc0z0nT8XIeewNR13UB |
| ContentType | Journal Article |
| DBID | CGR CUY CVF ECM EIF NPM 7X8 |
| DOI | 10.1259/0007-1285-69-825-855 |
| DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic |
| DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
| DatabaseTitleList | MEDLINE MEDLINE - Academic |
| Database_xml | – sequence: 1 dbid: NPM name: PubMed url: http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: 7X8 name: MEDLINE - Academic url: https://search.proquest.com/medline sourceTypes: Aggregation Database |
| DeliveryMethod | no_fulltext_linktorsrc |
| Discipline | Medicine Physics |
| ExternalDocumentID | 8983591 |
| Genre | Journal Article Comparative Study |
| GroupedDBID | --- .55 .GJ 0R~ 169 18M 1CY 1KJ 1OB 1OC 23N 24P 2WC 33P 34G 36B 39C 4.4 53G 5GY 5RE 5WD 6J9 AANLZ AASGY AAUAY AAWTL AAXRX ABCUV ABDFA ABEFU ABEJV ABGNP ABJNI ABNHQ ABQNK ABSZQ ABXGK ABXVV ACAHQ ACCZN ACGFO ACGOF ACPOU ACXBN ACZBC ADBBV ADBTR ADIPN ADMGS ADOZA ADVOB ADXAS AEGXH AEIGN AENEX AEUYR AFFNX AFFQV AGMDO AHMMS AI. AIACR AIAGR AIURR ALMA_UNASSIGNED_HOLDINGS ALUQN AMYDB AOIJS BAWUL BCRHZ BFHJK C1A C45 CGR CS3 CUY CVF DCZOG DIK DRFUL DRMAN DRSTM DU5 E3Z EBD EBS ECM EIF EJD EMB EMOBN F5P FRP GX1 H13 HDBZQ HYE IH2 J5H K-O KBYEO KOP L7B LATKE LEEKS LYRES MXFUL MXMAN MXSTM N4W NPM OCZFY OJZSN OK1 OVD OWPYF P0W P2P PKN RJQFR ROX RPM SJN SUPJJ SV3 TEORI TR2 TUS TWZ TXR UCJ VH1 W8F WOQ X7M ZGI ZXP ZZTAW 7X8 ADNBA AJAOE AJNCP |
| ID | FETCH-LOGICAL-g177t-5e2e84f76ebb025c5501e533bb2634c109ddf816c47e900fef6a5c7c2777d6bf2 |
| IEDL.DBID | 7X8 |
| ISSN | 0007-1285 |
| IngestDate | Mon Sep 29 06:41:37 EDT 2025 Wed Feb 19 01:22:20 EST 2025 |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 825 |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-g177t-5e2e84f76ebb025c5501e533bb2634c109ddf816c47e900fef6a5c7c2777d6bf2 |
| Notes | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
| PMID | 8983591 |
| PQID | 78589794 |
| PQPubID | 23479 |
| ParticipantIDs | proquest_miscellaneous_78589794 pubmed_primary_8983591 |
| PublicationCentury | 1900 |
| PublicationDate | 1996-Sep |
| PublicationDateYYYYMMDD | 1996-09-01 |
| PublicationDate_xml | – month: 09 year: 1996 text: 1996-Sep |
| PublicationDecade | 1990 |
| PublicationPlace | England |
| PublicationPlace_xml | – name: England |
| PublicationTitle | British journal of radiology |
| PublicationTitleAlternate | Br J Radiol |
| PublicationYear | 1996 |
| SSID | ssj0007590 |
| Score | 1.4742897 |
| Snippet | The output video signal from three X-ray fluoroscopy machines was recorded with a storage oscilloscope to calculate the dynamic range of their image... |
| SourceID | proquest pubmed |
| SourceType | Aggregation Database Index Database |
| StartPage | 855 |
| SubjectTerms | Fluoroscopy - standards Humans Quality Control |
| Title | Short communication: use of the output video signal for dynamic range, brightness control and image memory assessment in X-ray fluoroscopy |
| URI | https://www.ncbi.nlm.nih.gov/pubmed/8983591 https://www.proquest.com/docview/78589794 |
| Volume | 69 |
| hasFullText | |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://cvtisr.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1La9tAEB6SJim99OEk1H2kc-gxSyR5V7tbAiGUmh4SE-gD34z2lRgaybWtgv9CfnVnJdnNpeSQiw4CCbEaffpm9pv5AD66JEQPJEpTHU8YV14wkxeK8TQYYYPitim4_byQo5Eaj_XVFpyue2GirHKNiQ1Qu8rGGvmJVEJpCp6z2W8WPaPi3mpnoLENO4N0oKJxgxz_mxUuRVthicU4QmHRNc4R3z_ZnGO5ZpQjMSXE_ylm86sZvnjcQ76E5x3FxPM2Jl7Bli978PSy20TvwV6j-rSLfbj7dkPsG-39JpFPWC88VgGJGWJVL2f1EmOvXoVR6kH3JZaLrvWxx3lsTThG06T4ETSxk75jUTqc3hJY4W3U8q6w2IwAxWmJYzYvVhh-1VWcplnNVgfwY_jl--evrDNnYNeplEsmfOYVDzL3xhBvspTppJ64ozFZPuA2TbRzQaW55dLrJAk-5IWw0mZSSpebkB3Ck7Iq_WtAa1xmfZIX2hmufaYJ-IqB8VyaYGXi-vBhvdoTCv64o1GUvqoXk_V69-GwfWGTWTujY6I0UUudvnnw0rfwrBViR9nYO9gJ9NX797Br_yyni_lRE1J0HF1d_gXL99i9 |
| linkProvider | ProQuest |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Short+communication%3A+use+of+the+output+video+signal+for+dynamic+range%2C+brightness+control+and+image+memory+assessment+in+X-ray+fluoroscopy&rft.jtitle=British+journal+of+radiology&rft.au=Okkalides%2C+D&rft.date=1996-09-01&rft.issn=0007-1285&rft.volume=69&rft.issue=825&rft.spage=855&rft_id=info:doi/10.1259%2F0007-1285-69-825-855&rft_id=info%3Apmid%2F8983591&rft_id=info%3Apmid%2F8983591&rft.externalDocID=8983591 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0007-1285&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0007-1285&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0007-1285&client=summon |