Optimal Sewer Network Design Including Pumping Stations
In urban areas with a flat terrain, pumping stations must be included to elevate wastewater and avoid extreme excavation depths. These systems are characterized by high operational costs due to the pump’s power consumption. The present work presents a methodology for the optimal design of sewer netw...
Gespeichert in:
| Veröffentlicht in: | Engineering proceedings Jg. 69; H. 1; S. 16 |
|---|---|
| Hauptverfasser: | , , , , |
| Format: | Journal Article |
| Sprache: | Englisch |
| Veröffentlicht: |
MDPI AG
01.08.2024
|
| Schlagworte: | |
| ISSN: | 2673-4591 |
| Online-Zugang: | Volltext |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| Zusammenfassung: | In urban areas with a flat terrain, pumping stations must be included to elevate wastewater and avoid extreme excavation depths. These systems are characterized by high operational costs due to the pump’s power consumption. The present work presents a methodology for the optimal design of sewer networks including pumping stations, whose objective function is to minimize the construction and operation costs of the system. The methodology was tested on three sewer benchmark networks using two cost functions proposed in the literature. In all the sewer benchmarks, the cost achieved in the present work was compared with the best costs reported in the literature. |
|---|---|
| ISSN: | 2673-4591 |
| DOI: | 10.3390/engproc2024069016 |