Reduced graphene oxide (rGO) based wideband optical sensor and the role of Temperature, Defect States and Quantum Efficiency

We report a facile and cost-effective approach to develop self-standing reduced Graphene Oxide (rGO) film based optical sensor and its low-temperature performance analysis where midgap defect states play a key role in tuning the crucial sensor parameters. Graphite oxide (GO) is produced by modified...

Celý popis

Uloženo v:
Podrobná bibliografie
Vydáno v:Scientific reports Ročník 8; číslo 1; s. 3537 - 13
Hlavní autoři: Abid, Sehrawat, Poonam, Islam, S. S., Mishra, Prabhash, Ahmad, Shahab
Médium: Journal Article
Jazyk:angličtina
Vydáno: London Nature Publishing Group UK 23.02.2018
Nature Publishing Group
Nature Portfolio
Témata:
ISSN:2045-2322, 2045-2322
On-line přístup:Získat plný text
Tagy: Přidat tag
Žádné tagy, Buďte první, kdo vytvoří štítek k tomuto záznamu!
Popis
Shrnutí:We report a facile and cost-effective approach to develop self-standing reduced Graphene Oxide (rGO) film based optical sensor and its low-temperature performance analysis where midgap defect states play a key role in tuning the crucial sensor parameters. Graphite oxide (GO) is produced by modified Hummers’ method and reduced thermally at 250 °C for 1 h in Argon atmosphere to obtain rGO. Self-standing rGO film is prepared via vacuum filtration. The developed film is characterized by HRTEM, FESEM, Raman, and XRD techniques. The developed sensor exhibits highest sensitivity towards 635 nm illumination wavelength, irrespective of the operating temperature. For a given excitation wavelength, photoresponse study at low temperature (123K–303K) reveals inverse relationship between sensitivity and operating temperature. Highest sensitivity of 49.2% is obtained at 123 K for 635 nm laser at power density of 1.4 mW/mm 2 . Unlike sensitivity, response- and recovery-time demonstrate directly proportional dependence with operating temperature. Power dependent studies establish linear relation between power-density and sensitivity, and a safe limit beyond which sample heating prolongs the recovery time. Wavelength-dependent studies shows that proposed sensor can efficiently operate from visible to near NIR region. To the best of our knowledge such rGO based optical sensor performance at low temperature had not been reported earlier.
Bibliografie:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:2045-2322
2045-2322
DOI:10.1038/s41598-018-21686-2